Indoor Outdoor Relationship Of Fine Particles (PM2.5) IN School Classroom
People spend about 90 % of their lifetime indoors and indoor air pollution is one of the most harmful environmental factors for human health. Studies have shown that there is significant relationship between indoor air quality (IAQ) status with surrounding activities. In this study, PM2.5 concentrat...
Saved in:
Main Author: | |
---|---|
Format: | Monograph |
Language: | English |
Published: |
Universiti Sains Malaysia
2017
|
Subjects: | |
Online Access: | http://eprints.usm.my/52130/1/Indoor%20Outdoor%20Relationship%20Of%20Fine%20Particles%20%28PM2.5%29%20IN%20School%20Classroom_Muhamad%20Al-Amin%20Kamaruddin_A9_2017.pdf http://eprints.usm.my/52130/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.usm.eprints.52130 |
---|---|
record_format |
eprints |
spelling |
my.usm.eprints.52130 http://eprints.usm.my/52130/ Indoor Outdoor Relationship Of Fine Particles (PM2.5) IN School Classroom Kamaruddin, Muhamad Al-Amin T Technology TA Engineering (General). Civil engineering (General) People spend about 90 % of their lifetime indoors and indoor air pollution is one of the most harmful environmental factors for human health. Studies have shown that there is significant relationship between indoor air quality (IAQ) status with surrounding activities. In this study, PM2.5 concentration was monitored during teaching and learning session from 8.00 a.m. to 2.00 p.m. at two primary schools exposed to different major expected sources that are industry (Sekolah Kebangsaan Sungai Kechil) and mobile (Sekolah Kebangsaan Khir Johari) sources. The effect of building design towards the intrusion of outdoor PM2.5 into the indoor air quality in classroom was investigated. In each school, two rooms have been selected based on the type of window that is installed in a room with a window that uses a louvre and sliding window. The average of PM2.5 concentration in classroom with louvre window (CLW) and classroom with sliding window (CSW) were obtained which for SK Sungai Kechil (value for CLW and CSW) were 13 μg/m³ and 35 μg/m³ while for SK Khir Johari (value for CLS and CSW) were 27 μg/m³ and 37 μg/m³. Results shows that there exist statistically significant differences (p-value <0.05) of parameter indoor and outdoor PM2.5 concentration between these two schools. As a conclusion, the influence from the surrounding activities and indoor sources are important in contributing on indoor concentrations of pollutants in school classroom. Universiti Sains Malaysia 2017-06-01 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/52130/1/Indoor%20Outdoor%20Relationship%20Of%20Fine%20Particles%20%28PM2.5%29%20IN%20School%20Classroom_Muhamad%20Al-Amin%20Kamaruddin_A9_2017.pdf Kamaruddin, Muhamad Al-Amin (2017) Indoor Outdoor Relationship Of Fine Particles (PM2.5) IN School Classroom. Project Report. Universiti Sains Malaysia, Pusat Pengajian Kejuruteraan Awam. (Submitted) |
institution |
Universiti Sains Malaysia |
building |
Hamzah Sendut Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Sains Malaysia |
content_source |
USM Institutional Repository |
url_provider |
http://eprints.usm.my/ |
language |
English |
topic |
T Technology TA Engineering (General). Civil engineering (General) |
spellingShingle |
T Technology TA Engineering (General). Civil engineering (General) Kamaruddin, Muhamad Al-Amin Indoor Outdoor Relationship Of Fine Particles (PM2.5) IN School Classroom |
description |
People spend about 90 % of their lifetime indoors and indoor air pollution is one of the most harmful environmental factors for human health. Studies have shown that there is significant relationship between indoor air quality (IAQ) status with surrounding activities. In this study, PM2.5 concentration was monitored during teaching and learning session from 8.00 a.m. to 2.00 p.m. at two primary schools exposed to different major expected sources that are industry (Sekolah Kebangsaan Sungai Kechil) and mobile (Sekolah Kebangsaan Khir Johari) sources. The effect of building design towards the intrusion of outdoor PM2.5 into the indoor air quality in classroom was investigated. In each school, two rooms have been selected based on the type of window that is installed in a room with a window that uses a louvre and sliding window. The average of PM2.5 concentration in classroom with louvre window (CLW) and classroom with sliding window (CSW) were obtained which for SK Sungai Kechil (value for CLW and CSW) were 13 μg/m³ and 35 μg/m³ while for SK Khir Johari (value for CLS and CSW) were 27 μg/m³ and 37 μg/m³. Results shows that there exist statistically significant differences (p-value <0.05) of parameter indoor and outdoor PM2.5 concentration between these two schools. As a conclusion, the influence from the surrounding activities and indoor sources are important in contributing on indoor concentrations of pollutants in school classroom. |
format |
Monograph |
author |
Kamaruddin, Muhamad Al-Amin |
author_facet |
Kamaruddin, Muhamad Al-Amin |
author_sort |
Kamaruddin, Muhamad Al-Amin |
title |
Indoor Outdoor Relationship Of Fine Particles (PM2.5) IN School Classroom |
title_short |
Indoor Outdoor Relationship Of Fine Particles (PM2.5) IN School Classroom |
title_full |
Indoor Outdoor Relationship Of Fine Particles (PM2.5) IN School Classroom |
title_fullStr |
Indoor Outdoor Relationship Of Fine Particles (PM2.5) IN School Classroom |
title_full_unstemmed |
Indoor Outdoor Relationship Of Fine Particles (PM2.5) IN School Classroom |
title_sort |
indoor outdoor relationship of fine particles (pm2.5) in school classroom |
publisher |
Universiti Sains Malaysia |
publishDate |
2017 |
url |
http://eprints.usm.my/52130/1/Indoor%20Outdoor%20Relationship%20Of%20Fine%20Particles%20%28PM2.5%29%20IN%20School%20Classroom_Muhamad%20Al-Amin%20Kamaruddin_A9_2017.pdf http://eprints.usm.my/52130/ |
_version_ |
1729703919710371840 |
score |
13.160551 |