Optimization of the Differential Pulse Cathodic Stripping Voltammetry Technique for the Determination of Nickel in Pengkalan Chepa River, Kelantan

Nickel is a very toxic heavy metal which is significant subject of environmental surveillance, food control and occupational medicine, toxicology and hygiene. Various techniques have been used for the determination of this heavy metal including inductively"coupled plasma mass spectrometry (I...

Full description

Saved in:
Bibliographic Details
Main Author: Azlina, Mat Shariff
Format: Monograph
Language:English
Published: Universiti Sains Malaysia 2009
Subjects:
Online Access:http://eprints.usm.my/51030/1/AZLINA%20BINTI%20MAT%20SHARIFF%20-%2024%20pages.pdf
http://eprints.usm.my/51030/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.usm.eprints.51030
record_format eprints
spelling my.usm.eprints.51030 http://eprints.usm.my/51030/ Optimization of the Differential Pulse Cathodic Stripping Voltammetry Technique for the Determination of Nickel in Pengkalan Chepa River, Kelantan Azlina, Mat Shariff R Medicine (General) Nickel is a very toxic heavy metal which is significant subject of environmental surveillance, food control and occupational medicine, toxicology and hygiene. Various techniques have been used for the determination of this heavy metal including inductively"coupled plasma mass spectrometry (ICP"MS}, flame atomic absorption spectrometry (F AAS) and atomic emission spectrometry (AES). However, these methods are having disadvantages particularly time consuming in sample preparation. A voltammetric method as an alternative method for the determination of the nickel in the river water samples of Pengkalan Chepa River is described. In this study the determination of nickel in the river water samples collected from Pengkalan Chepa River was performed by using Differential Pulse Cathodic Stripping Voltammetry (DPCSV) analysis. All samples were collected from Pengkalan Chepa River at various places including those from surface and the bottom of the river. From the study, the optimum condition for the supporting electrolyte, Britton-Robinson Buffer (BRB), 0.04 M was determined to be at pH 4. The optimum voltammetric parameters with initial potential, Ei was -0.70 V, fmal potential, Er was "1.15 V, scan rate, v was 0.020 V/s, deposition potential, Eacc was -0.70 V, deposition time, tacc was 0 second and equilibrium time, teq was 10 seconds. The calibration curve was constructed, using peak height, Ip versus concentration of nickel standard solution (5 ppm). A linear graph with regression equation, Y= 20.131X + 0.743 and correlation coefficient, r was 0.999. Standard deviation (SD) was 1.063, sensitivity 20.131 nA/ppm and limit of detection was 0.158 ppm or 158 ppb. The results from this study show that nickel was not detected in all samples using our experimental conditions. Universiti Sains Malaysia 2009 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/51030/1/AZLINA%20BINTI%20MAT%20SHARIFF%20-%2024%20pages.pdf Azlina, Mat Shariff (2009) Optimization of the Differential Pulse Cathodic Stripping Voltammetry Technique for the Determination of Nickel in Pengkalan Chepa River, Kelantan. Other. Universiti Sains Malaysia. (Submitted)
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic R Medicine (General)
spellingShingle R Medicine (General)
Azlina, Mat Shariff
Optimization of the Differential Pulse Cathodic Stripping Voltammetry Technique for the Determination of Nickel in Pengkalan Chepa River, Kelantan
description Nickel is a very toxic heavy metal which is significant subject of environmental surveillance, food control and occupational medicine, toxicology and hygiene. Various techniques have been used for the determination of this heavy metal including inductively"coupled plasma mass spectrometry (ICP"MS}, flame atomic absorption spectrometry (F AAS) and atomic emission spectrometry (AES). However, these methods are having disadvantages particularly time consuming in sample preparation. A voltammetric method as an alternative method for the determination of the nickel in the river water samples of Pengkalan Chepa River is described. In this study the determination of nickel in the river water samples collected from Pengkalan Chepa River was performed by using Differential Pulse Cathodic Stripping Voltammetry (DPCSV) analysis. All samples were collected from Pengkalan Chepa River at various places including those from surface and the bottom of the river. From the study, the optimum condition for the supporting electrolyte, Britton-Robinson Buffer (BRB), 0.04 M was determined to be at pH 4. The optimum voltammetric parameters with initial potential, Ei was -0.70 V, fmal potential, Er was "1.15 V, scan rate, v was 0.020 V/s, deposition potential, Eacc was -0.70 V, deposition time, tacc was 0 second and equilibrium time, teq was 10 seconds. The calibration curve was constructed, using peak height, Ip versus concentration of nickel standard solution (5 ppm). A linear graph with regression equation, Y= 20.131X + 0.743 and correlation coefficient, r was 0.999. Standard deviation (SD) was 1.063, sensitivity 20.131 nA/ppm and limit of detection was 0.158 ppm or 158 ppb. The results from this study show that nickel was not detected in all samples using our experimental conditions.
format Monograph
author Azlina, Mat Shariff
author_facet Azlina, Mat Shariff
author_sort Azlina, Mat Shariff
title Optimization of the Differential Pulse Cathodic Stripping Voltammetry Technique for the Determination of Nickel in Pengkalan Chepa River, Kelantan
title_short Optimization of the Differential Pulse Cathodic Stripping Voltammetry Technique for the Determination of Nickel in Pengkalan Chepa River, Kelantan
title_full Optimization of the Differential Pulse Cathodic Stripping Voltammetry Technique for the Determination of Nickel in Pengkalan Chepa River, Kelantan
title_fullStr Optimization of the Differential Pulse Cathodic Stripping Voltammetry Technique for the Determination of Nickel in Pengkalan Chepa River, Kelantan
title_full_unstemmed Optimization of the Differential Pulse Cathodic Stripping Voltammetry Technique for the Determination of Nickel in Pengkalan Chepa River, Kelantan
title_sort optimization of the differential pulse cathodic stripping voltammetry technique for the determination of nickel in pengkalan chepa river, kelantan
publisher Universiti Sains Malaysia
publishDate 2009
url http://eprints.usm.my/51030/1/AZLINA%20BINTI%20MAT%20SHARIFF%20-%2024%20pages.pdf
http://eprints.usm.my/51030/
_version_ 1720980902232719360