Semi-quantitative assessment of myocardial perfusion abnormality on different reconstructed spect polar MAPS

Aim: The aim of this study is to assess the validation of summed segmental scores in detection accuracy CAD from different reconstructed polar maps. Method: The summed scores (SSS, SRS and SDS) were obtained from standard filtered backprojection reconstruction (FBP) and iterative reconstruction wit...

Full description

Saved in:
Bibliographic Details
Main Author: Zahir, Nur Syazana Mohd
Format: Thesis
Language:English
Published: 2020
Subjects:
Online Access:http://eprints.usm.my/50988/1/Nur%20Syazana-24%20pages.pdf
http://eprints.usm.my/50988/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.usm.eprints.50988
record_format eprints
spelling my.usm.eprints.50988 http://eprints.usm.my/50988/ Semi-quantitative assessment of myocardial perfusion abnormality on different reconstructed spect polar MAPS Zahir, Nur Syazana Mohd R Medicine Aim: The aim of this study is to assess the validation of summed segmental scores in detection accuracy CAD from different reconstructed polar maps. Method: The summed scores (SSS, SRS and SDS) were obtained from standard filtered backprojection reconstruction (FBP) and iterative reconstruction with CT-AC that being performed on the raw emission data of 30 patients (15 male and 15 females) with known or suspected coronary artery disease who had undergone two-day stress-rest or rest-stress 99mTc-MIBI myocardial perfusion SPECT. The reconstruction algorithms and the resulting projected polar maps were used to estimate the radioactivity distribution within the left ventricular myocardium of the heart. Result: Mean ± SD for all summed scores is higher in FBP than CT-AC with SSS in FBP 32.60 ± 5.360, SRS FBP 31.60 ± 5.069 and SDS FBP 3.87 ± 3.159. Meanwhile for SSS in CT-AC is 28.27 ± 5.245, SRS CT-AC 27.20 ± 4.397 and SDS CT-AC 3.27 ± 2.449. There is statistically significant difference of SSS and SRS between FBP and CT-AC tested using Mann-Whitney test (p value = 0.002 for SSS and p-value = 0.001 for SRS). However, there is no statistically significant difference of SDS between FBP and CT-AC tested using Mann-Whitney test (p value = 0.633). Conclusion: Summed scores studies reconstructed with FBP are statistically not significantly different from AC. However, compensation for attenuation artifact is much better with iterative reconstruction CT-AC that FBP as CT-AC for SPECT MPI allows improved specificity of RCA territory compared with FBP reconstruction SPECT MPI. 2020 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/50988/1/Nur%20Syazana-24%20pages.pdf Zahir, Nur Syazana Mohd (2020) Semi-quantitative assessment of myocardial perfusion abnormality on different reconstructed spect polar MAPS. Masters thesis, Universiti Sains Malaysia.
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic R Medicine
spellingShingle R Medicine
Zahir, Nur Syazana Mohd
Semi-quantitative assessment of myocardial perfusion abnormality on different reconstructed spect polar MAPS
description Aim: The aim of this study is to assess the validation of summed segmental scores in detection accuracy CAD from different reconstructed polar maps. Method: The summed scores (SSS, SRS and SDS) were obtained from standard filtered backprojection reconstruction (FBP) and iterative reconstruction with CT-AC that being performed on the raw emission data of 30 patients (15 male and 15 females) with known or suspected coronary artery disease who had undergone two-day stress-rest or rest-stress 99mTc-MIBI myocardial perfusion SPECT. The reconstruction algorithms and the resulting projected polar maps were used to estimate the radioactivity distribution within the left ventricular myocardium of the heart. Result: Mean ± SD for all summed scores is higher in FBP than CT-AC with SSS in FBP 32.60 ± 5.360, SRS FBP 31.60 ± 5.069 and SDS FBP 3.87 ± 3.159. Meanwhile for SSS in CT-AC is 28.27 ± 5.245, SRS CT-AC 27.20 ± 4.397 and SDS CT-AC 3.27 ± 2.449. There is statistically significant difference of SSS and SRS between FBP and CT-AC tested using Mann-Whitney test (p value = 0.002 for SSS and p-value = 0.001 for SRS). However, there is no statistically significant difference of SDS between FBP and CT-AC tested using Mann-Whitney test (p value = 0.633). Conclusion: Summed scores studies reconstructed with FBP are statistically not significantly different from AC. However, compensation for attenuation artifact is much better with iterative reconstruction CT-AC that FBP as CT-AC for SPECT MPI allows improved specificity of RCA territory compared with FBP reconstruction SPECT MPI.
format Thesis
author Zahir, Nur Syazana Mohd
author_facet Zahir, Nur Syazana Mohd
author_sort Zahir, Nur Syazana Mohd
title Semi-quantitative assessment of myocardial perfusion abnormality on different reconstructed spect polar MAPS
title_short Semi-quantitative assessment of myocardial perfusion abnormality on different reconstructed spect polar MAPS
title_full Semi-quantitative assessment of myocardial perfusion abnormality on different reconstructed spect polar MAPS
title_fullStr Semi-quantitative assessment of myocardial perfusion abnormality on different reconstructed spect polar MAPS
title_full_unstemmed Semi-quantitative assessment of myocardial perfusion abnormality on different reconstructed spect polar MAPS
title_sort semi-quantitative assessment of myocardial perfusion abnormality on different reconstructed spect polar maps
publishDate 2020
url http://eprints.usm.my/50988/1/Nur%20Syazana-24%20pages.pdf
http://eprints.usm.my/50988/
_version_ 1720980896438288384
score 13.214268