Voltammetric Determination of Nickel in Chocolate by Differential Pulse Cathodic Stripping Analysis

The determination of nickel in the chocolate was performed by Differential Pulse Cathodic Stripping Analysis(DPCSV). Chocolate was a complex sample with a high content of organic compounds such as sugar, protein, fat, lecithin and many more and its analysis generally involves digestion procedures...

Full description

Saved in:
Bibliographic Details
Main Author: Mohammad Zairy Azren, Jainal@ Zainal
Format: Monograph
Language:English
Published: PPSP, Universiti Sains Malaysia 2007
Subjects:
Online Access:http://eprints.usm.my/50210/1/MOHAMAD%20ZAIRY%20AZREN%20BIN%20JAINAL%40%20ZAINAL-%2024%20pages.pdf
http://eprints.usm.my/50210/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.usm.eprints.50210
record_format eprints
spelling my.usm.eprints.50210 http://eprints.usm.my/50210/ Voltammetric Determination of Nickel in Chocolate by Differential Pulse Cathodic Stripping Analysis Mohammad Zairy Azren, Jainal@ Zainal R Medicine (General) The determination of nickel in the chocolate was performed by Differential Pulse Cathodic Stripping Analysis(DPCSV). Chocolate was a complex sample with a high content of organic compounds such as sugar, protein, fat, lecithin and many more and its analysis generally involves digestion procedures that might include the risk of losses and/or contamination. Wet digestion by using concentrated nitric acid and 1:1 ratio of distilled water-hydrochloric acid on the sample was selected on this study because of its availability and low cost . Sample was then processed to the sample analysis stage. Prior to the sample analysis by DPCSV, the optimum pH for the supporting electrolyte, Britton-Robinson Buffer (BRB}, 0.04 M and optimum parameters for the analysis was determined. Optimum pH for the supporting electrolyte, BRB was pH 4. Initial potential, Ei of -0.68 V, final potential, Er of-1.15 V, scan rate of0.050 V/s, deposition potential of -1.4 V, equilibration time of 5 s and deposition time, tacc of 20 s were the optimized parameters used in this study. The validation of methodology was performed by plotting a calibration curve peak height, ip versus different concentrations of nickel (5 ppm) as the stock solution. A linear graph with the regression equation of Y= 0.820+ 23.322X, correlation coefficient of 0.966, standard deviation of 1.129, sensitivity of 23.322 nA/ppm and limit of detection of 0.145 ppm was obtained. 3 different brands of chocolate were analyzed. The results in all samples show absence of nickel. PPSP, Universiti Sains Malaysia 2007 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/50210/1/MOHAMAD%20ZAIRY%20AZREN%20BIN%20JAINAL%40%20ZAINAL-%2024%20pages.pdf Mohammad Zairy Azren, Jainal@ Zainal (2007) Voltammetric Determination of Nickel in Chocolate by Differential Pulse Cathodic Stripping Analysis. Other. PPSP, Universiti Sains Malaysia. (Submitted)
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic R Medicine (General)
spellingShingle R Medicine (General)
Mohammad Zairy Azren, Jainal@ Zainal
Voltammetric Determination of Nickel in Chocolate by Differential Pulse Cathodic Stripping Analysis
description The determination of nickel in the chocolate was performed by Differential Pulse Cathodic Stripping Analysis(DPCSV). Chocolate was a complex sample with a high content of organic compounds such as sugar, protein, fat, lecithin and many more and its analysis generally involves digestion procedures that might include the risk of losses and/or contamination. Wet digestion by using concentrated nitric acid and 1:1 ratio of distilled water-hydrochloric acid on the sample was selected on this study because of its availability and low cost . Sample was then processed to the sample analysis stage. Prior to the sample analysis by DPCSV, the optimum pH for the supporting electrolyte, Britton-Robinson Buffer (BRB}, 0.04 M and optimum parameters for the analysis was determined. Optimum pH for the supporting electrolyte, BRB was pH 4. Initial potential, Ei of -0.68 V, final potential, Er of-1.15 V, scan rate of0.050 V/s, deposition potential of -1.4 V, equilibration time of 5 s and deposition time, tacc of 20 s were the optimized parameters used in this study. The validation of methodology was performed by plotting a calibration curve peak height, ip versus different concentrations of nickel (5 ppm) as the stock solution. A linear graph with the regression equation of Y= 0.820+ 23.322X, correlation coefficient of 0.966, standard deviation of 1.129, sensitivity of 23.322 nA/ppm and limit of detection of 0.145 ppm was obtained. 3 different brands of chocolate were analyzed. The results in all samples show absence of nickel.
format Monograph
author Mohammad Zairy Azren, Jainal@ Zainal
author_facet Mohammad Zairy Azren, Jainal@ Zainal
author_sort Mohammad Zairy Azren, Jainal@ Zainal
title Voltammetric Determination of Nickel in Chocolate by Differential Pulse Cathodic Stripping Analysis
title_short Voltammetric Determination of Nickel in Chocolate by Differential Pulse Cathodic Stripping Analysis
title_full Voltammetric Determination of Nickel in Chocolate by Differential Pulse Cathodic Stripping Analysis
title_fullStr Voltammetric Determination of Nickel in Chocolate by Differential Pulse Cathodic Stripping Analysis
title_full_unstemmed Voltammetric Determination of Nickel in Chocolate by Differential Pulse Cathodic Stripping Analysis
title_sort voltammetric determination of nickel in chocolate by differential pulse cathodic stripping analysis
publisher PPSP, Universiti Sains Malaysia
publishDate 2007
url http://eprints.usm.my/50210/1/MOHAMAD%20ZAIRY%20AZREN%20BIN%20JAINAL%40%20ZAINAL-%2024%20pages.pdf
http://eprints.usm.my/50210/
_version_ 1715190757407588352
score 13.211869