Voltammetric Determination of Cadmium in Infant Mllk

Among the various environmental pollutants, heavy metals like cadmium was considered the most important due to high stability for bioaccumulation they were extremely dangerous for all biological organisms and especially for humans. This is a great importance to analyze and quantify this toxic age...

Full description

Saved in:
Bibliographic Details
Main Author: Haznan, Hashim
Format: Monograph
Language:English
Published: PPSP, Universiti Sains Malaysia 2007
Subjects:
Online Access:http://eprints.usm.my/50144/1/HASNAN%20BIN%20HASHIM%20-%2024%20pages.pdf
http://eprints.usm.my/50144/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.usm.eprints.50144
record_format eprints
spelling my.usm.eprints.50144 http://eprints.usm.my/50144/ Voltammetric Determination of Cadmium in Infant Mllk Haznan, Hashim R Medicine (General) Among the various environmental pollutants, heavy metals like cadmium was considered the most important due to high stability for bioaccumulation they were extremely dangerous for all biological organisms and especially for humans. This is a great importance to analyze and quantify this toxic agent in the environment. Various methods have been done such as atomic absorption spectrometry (AAS), atomic emission spectrometry (AES) in determination of cadmium in matrix. Often these techniques require complex sample preparation and expensive instrumentation. In contrast, voltammetric methods particularly anodic stripping voltammetric (ASV) had some advantages such as little or no sample pretreatment is required, detection limit is as low as 1 o-10 M and low cost instrumentation. For this work, cadmium was studied in various brand of infant milk. Besides, aim of this work was to improve anodic stripping voltammetric (ASV) method for cadmium detection by optimizing voltammetric condition (pH) and voltammetric parameters such as initial potential (Ei), final potential (Er), scan rate (v), deposition potential (Eacc), deposition time (tacc). and equilibration time (feq) in ASV. The samples preparation was done by extraction using acid digestion and filtration using filter paper. The samples were analyzed under optimized voltammetric condition and parameters. Cadmium was not detected in any of studied under this project work. PPSP, Universiti Sains Malaysia 2007 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/50144/1/HASNAN%20BIN%20HASHIM%20-%2024%20pages.pdf Haznan, Hashim (2007) Voltammetric Determination of Cadmium in Infant Mllk. Other. PPSP, Universiti Sains Malaysia. (Submitted)
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic R Medicine (General)
spellingShingle R Medicine (General)
Haznan, Hashim
Voltammetric Determination of Cadmium in Infant Mllk
description Among the various environmental pollutants, heavy metals like cadmium was considered the most important due to high stability for bioaccumulation they were extremely dangerous for all biological organisms and especially for humans. This is a great importance to analyze and quantify this toxic agent in the environment. Various methods have been done such as atomic absorption spectrometry (AAS), atomic emission spectrometry (AES) in determination of cadmium in matrix. Often these techniques require complex sample preparation and expensive instrumentation. In contrast, voltammetric methods particularly anodic stripping voltammetric (ASV) had some advantages such as little or no sample pretreatment is required, detection limit is as low as 1 o-10 M and low cost instrumentation. For this work, cadmium was studied in various brand of infant milk. Besides, aim of this work was to improve anodic stripping voltammetric (ASV) method for cadmium detection by optimizing voltammetric condition (pH) and voltammetric parameters such as initial potential (Ei), final potential (Er), scan rate (v), deposition potential (Eacc), deposition time (tacc). and equilibration time (feq) in ASV. The samples preparation was done by extraction using acid digestion and filtration using filter paper. The samples were analyzed under optimized voltammetric condition and parameters. Cadmium was not detected in any of studied under this project work.
format Monograph
author Haznan, Hashim
author_facet Haznan, Hashim
author_sort Haznan, Hashim
title Voltammetric Determination of Cadmium in Infant Mllk
title_short Voltammetric Determination of Cadmium in Infant Mllk
title_full Voltammetric Determination of Cadmium in Infant Mllk
title_fullStr Voltammetric Determination of Cadmium in Infant Mllk
title_full_unstemmed Voltammetric Determination of Cadmium in Infant Mllk
title_sort voltammetric determination of cadmium in infant mllk
publisher PPSP, Universiti Sains Malaysia
publishDate 2007
url http://eprints.usm.my/50144/1/HASNAN%20BIN%20HASHIM%20-%2024%20pages.pdf
http://eprints.usm.my/50144/
_version_ 1713200640081002496