Exposure rate in mobile c-arm fluoroscopy and radioiodine therapy

This study is done to measure the exposure rate from mobile c-arm fluoroscopy and patients undergo radioiodine therapy. The measurement of exposure rate from mobile c-arm fluoroscopy was carried out using survey meter model 451 B, and also lead apron with 0.5 mm lead equivalence thickness. The ex...

Full description

Saved in:
Bibliographic Details
Main Author: Shalleh, Norzulaili Md
Format: Thesis
Language:English
Published: 2004
Subjects:
Online Access:http://eprints.usm.my/46336/1/LI...Norzulaili%20Binti%20Md.Shalleh...2004...-24%20pages.pdf
http://eprints.usm.my/46336/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.usm.eprints.46336
record_format eprints
spelling my.usm.eprints.46336 http://eprints.usm.my/46336/ Exposure rate in mobile c-arm fluoroscopy and radioiodine therapy Shalleh, Norzulaili Md R Medicine (General) This study is done to measure the exposure rate from mobile c-arm fluoroscopy and patients undergo radioiodine therapy. The measurement of exposure rate from mobile c-arm fluoroscopy was carried out using survey meter model 451 B, and also lead apron with 0.5 mm lead equivalence thickness. The exposure time, distance, shielding material and value of kVp and mAs were considered. This study was done by varied the exposure time of mobile c-arm fluoroscopy while the value of kVp was remaining constant. This was done to see the effect of exposure time to the exposure rate. From this study, we found that the exposure rate was increased exponentially with exposure time. This study also done by varied the distance of survey meter from mobile c-arm fluoroscopy. This was done to see the effect of distance to the exposure rate. From this study, we found that the exposure rate decreased for about 30% when the distance increased by 1 0 em. Besides that, this study was also done; by covering the survey meter with lead apron with 0.5 mm lead equivalence thickness. This was done to see the effect of shielding to the exposure rate. We found that the exposure rate decreased for more than 90o/o when the lead apron was used. We also measured the exposure rate from patients undergo radioiodine therapy. This study was done after the patients had drunk the radioiodine solution for 30 minutes. This study also used survey meter model 451 B to measure the exposure rate from various distance. From this study, we found that the exposure rate from radioiodine therapy patients decreased exponentially with increasing distance. As conclusion, we can say that the exposure rate from mobile c-arm fluoroscopy and patients undergo radioiodine therapy, can be minimized by increasing distance, decreasing exposure time, and also by using shielding materials. 2004 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/46336/1/LI...Norzulaili%20Binti%20Md.Shalleh...2004...-24%20pages.pdf Shalleh, Norzulaili Md (2004) Exposure rate in mobile c-arm fluoroscopy and radioiodine therapy. Other thesis, Universiti Sains Malaysia.
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic R Medicine (General)
spellingShingle R Medicine (General)
Shalleh, Norzulaili Md
Exposure rate in mobile c-arm fluoroscopy and radioiodine therapy
description This study is done to measure the exposure rate from mobile c-arm fluoroscopy and patients undergo radioiodine therapy. The measurement of exposure rate from mobile c-arm fluoroscopy was carried out using survey meter model 451 B, and also lead apron with 0.5 mm lead equivalence thickness. The exposure time, distance, shielding material and value of kVp and mAs were considered. This study was done by varied the exposure time of mobile c-arm fluoroscopy while the value of kVp was remaining constant. This was done to see the effect of exposure time to the exposure rate. From this study, we found that the exposure rate was increased exponentially with exposure time. This study also done by varied the distance of survey meter from mobile c-arm fluoroscopy. This was done to see the effect of distance to the exposure rate. From this study, we found that the exposure rate decreased for about 30% when the distance increased by 1 0 em. Besides that, this study was also done; by covering the survey meter with lead apron with 0.5 mm lead equivalence thickness. This was done to see the effect of shielding to the exposure rate. We found that the exposure rate decreased for more than 90o/o when the lead apron was used. We also measured the exposure rate from patients undergo radioiodine therapy. This study was done after the patients had drunk the radioiodine solution for 30 minutes. This study also used survey meter model 451 B to measure the exposure rate from various distance. From this study, we found that the exposure rate from radioiodine therapy patients decreased exponentially with increasing distance. As conclusion, we can say that the exposure rate from mobile c-arm fluoroscopy and patients undergo radioiodine therapy, can be minimized by increasing distance, decreasing exposure time, and also by using shielding materials.
format Thesis
author Shalleh, Norzulaili Md
author_facet Shalleh, Norzulaili Md
author_sort Shalleh, Norzulaili Md
title Exposure rate in mobile c-arm fluoroscopy and radioiodine therapy
title_short Exposure rate in mobile c-arm fluoroscopy and radioiodine therapy
title_full Exposure rate in mobile c-arm fluoroscopy and radioiodine therapy
title_fullStr Exposure rate in mobile c-arm fluoroscopy and radioiodine therapy
title_full_unstemmed Exposure rate in mobile c-arm fluoroscopy and radioiodine therapy
title_sort exposure rate in mobile c-arm fluoroscopy and radioiodine therapy
publishDate 2004
url http://eprints.usm.my/46336/1/LI...Norzulaili%20Binti%20Md.Shalleh...2004...-24%20pages.pdf
http://eprints.usm.my/46336/
_version_ 1662755770667630592
score 13.214268