Introduction: Human postocclusive forearm skin reactive hyperemia is not only a potential means of identifying early signs of cardiovascular diseases, it can also be used in the assessment of local microvascular response to topically applied compounds on skin. The method is not fully characterized...

Full description

Saved in:
Bibliographic Details
Main Authors: Rasool, Aida Hanum Ghulam, Rahman, Abdul Rashid Abdul
Format: Article
Language:English
Published: Pusat Pengajian Sains Perubatan, Universiti Sains Malaysia 2004
Subjects:
Online Access:http://eprints.usm.my/45655/1/GP...Method%20Optimisation%20And%20Validation%20Study%20On%20Use%20Of%20Laser%20Doppler%20Flowmetry%20To%20Assess%20Microvascular%20Endorhelial%20Function...2004...-24%20pages.pdf
http://eprints.usm.my/45655/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.usm.eprints.45655
record_format eprints
spelling my.usm.eprints.45655 http://eprints.usm.my/45655/ Method optimisation and validation study on use of laser doppler flowmetery to assess microvascular endothelial function Rasool, Aida Hanum Ghulam Rahman, Abdul Rashid Abdul RD Surgery Introduction: Human postocclusive forearm skin reactive hyperemia is not only a potential means of identifying early signs of cardiovascular diseases, it can also be used in the assessment of local microvascular response to topically applied compounds on skin. The method is not fully characterized. In this study, we investigated the influence of occlusion time on postocclusive forearm skin reactive hyperemia using laser Doppler fluximetly (LDF). Methods: Twenty healthy male volunteers were studied on three separate days (at least 24 lti h apart) via a randomized design. Volunteers were studied in a supine position while fasted. Laser Doppler probes were placed on the volar surface of the antebrachium. In preliminary studies, 3 min of upper arm blood flow occlusion at suprasystolic pressure was found to be the upper limit of tolerability. Subsequently, volunteers were randomized to receive 1, 2, or 3 min occlusion on 3 different days. Skin blood flux 1~ was measured before, during, and after occlusion using LDF. The primary outcome calculated was maximal change in ski11 blood flux before and after occlusion, expressed in arbitrary units (AU). Results: Skin blood flux changes (mean ± S.E.M.) after 1, 2, and 3 min occlusion period were 15.39 ± 1.27 AU, 24.84 ± 1.62 AU, and 32.14 ± 1.73 AU, respectively. Using repeated-measures analysis of variance (ANOVA), significant difference (P<.OS) in skin blood flux changes were revealed between these three occlusion durations, where 3 min occlusion produced significantly greater in skin blood flux occlusion change compared to I and 2 min occlusion. Conclusion: Three minutes of occlusion produces the greater postocclusive reactive hyperemia. It is recommended that studies using postocclusive forearm skin reactive hyperemia should occlude the forearm for at least 3 min. Pusat Pengajian Sains Perubatan, Universiti Sains Malaysia 2004-03 Article NonPeerReviewed application/pdf en http://eprints.usm.my/45655/1/GP...Method%20Optimisation%20And%20Validation%20Study%20On%20Use%20Of%20Laser%20Doppler%20Flowmetry%20To%20Assess%20Microvascular%20Endorhelial%20Function...2004...-24%20pages.pdf Rasool, Aida Hanum Ghulam and Rahman, Abdul Rashid Abdul (2004) Method optimisation and validation study on use of laser doppler flowmetery to assess microvascular endothelial function. Method optimisation and validation study on use of laser doppler flowmetery to assess microvascular endothelial function. (Submitted)
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic RD Surgery
spellingShingle RD Surgery
Rasool, Aida Hanum Ghulam
Rahman, Abdul Rashid Abdul
Method optimisation and validation study on use of laser doppler flowmetery to assess microvascular endothelial function
description Introduction: Human postocclusive forearm skin reactive hyperemia is not only a potential means of identifying early signs of cardiovascular diseases, it can also be used in the assessment of local microvascular response to topically applied compounds on skin. The method is not fully characterized. In this study, we investigated the influence of occlusion time on postocclusive forearm skin reactive hyperemia using laser Doppler fluximetly (LDF). Methods: Twenty healthy male volunteers were studied on three separate days (at least 24 lti h apart) via a randomized design. Volunteers were studied in a supine position while fasted. Laser Doppler probes were placed on the volar surface of the antebrachium. In preliminary studies, 3 min of upper arm blood flow occlusion at suprasystolic pressure was found to be the upper limit of tolerability. Subsequently, volunteers were randomized to receive 1, 2, or 3 min occlusion on 3 different days. Skin blood flux 1~ was measured before, during, and after occlusion using LDF. The primary outcome calculated was maximal change in ski11 blood flux before and after occlusion, expressed in arbitrary units (AU). Results: Skin blood flux changes (mean ± S.E.M.) after 1, 2, and 3 min occlusion period were 15.39 ± 1.27 AU, 24.84 ± 1.62 AU, and 32.14 ± 1.73 AU, respectively. Using repeated-measures analysis of variance (ANOVA), significant difference (P<.OS) in skin blood flux changes were revealed between these three occlusion durations, where 3 min occlusion produced significantly greater in skin blood flux occlusion change compared to I and 2 min occlusion. Conclusion: Three minutes of occlusion produces the greater postocclusive reactive hyperemia. It is recommended that studies using postocclusive forearm skin reactive hyperemia should occlude the forearm for at least 3 min.
format Article
author Rasool, Aida Hanum Ghulam
Rahman, Abdul Rashid Abdul
author_facet Rasool, Aida Hanum Ghulam
Rahman, Abdul Rashid Abdul
author_sort Rasool, Aida Hanum Ghulam
title Method optimisation and validation study on use of laser doppler flowmetery to assess microvascular endothelial function
title_short Method optimisation and validation study on use of laser doppler flowmetery to assess microvascular endothelial function
title_full Method optimisation and validation study on use of laser doppler flowmetery to assess microvascular endothelial function
title_fullStr Method optimisation and validation study on use of laser doppler flowmetery to assess microvascular endothelial function
title_full_unstemmed Method optimisation and validation study on use of laser doppler flowmetery to assess microvascular endothelial function
title_sort method optimisation and validation study on use of laser doppler flowmetery to assess microvascular endothelial function
publisher Pusat Pengajian Sains Perubatan, Universiti Sains Malaysia
publishDate 2004
url http://eprints.usm.my/45655/1/GP...Method%20Optimisation%20And%20Validation%20Study%20On%20Use%20Of%20Laser%20Doppler%20Flowmetry%20To%20Assess%20Microvascular%20Endorhelial%20Function...2004...-24%20pages.pdf
http://eprints.usm.my/45655/
_version_ 1648738925929299968
score 13.18916