Comparative Analysis of Mathematical Models for Blood Flow in Tapered Constricted Arteries

Pulsatile flow of blood in narrow tapered arteries with mild overlapping stenosis in the presence of periodic body acceleration is analyzed mathematically, treating it as two-fluid model with the suspension of all the erythrocytes in the core region as non-Newtonian fluid with yield stress and th...

Full description

Saved in:
Bibliographic Details
Main Authors: Sankar, D. S., Yatim, Yazariah
Format: Article
Language:English
Published: Hindawi Publishing Corporation 2012
Subjects:
Online Access:http://eprints.usm.my/38469/1/Comparative_Analysis_of_Mathematical_Models_for_Blood_Flow_in_Tapered_Constricted_Arteries.pdf
http://eprints.usm.my/38469/
https://doi.org/10.1155/2012/235960
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.usm.eprints.38469
record_format eprints
spelling my.usm.eprints.38469 http://eprints.usm.my/38469/ Comparative Analysis of Mathematical Models for Blood Flow in Tapered Constricted Arteries Sankar, D. S. Yatim, Yazariah QA1-939 Mathematics Pulsatile flow of blood in narrow tapered arteries with mild overlapping stenosis in the presence of periodic body acceleration is analyzed mathematically, treating it as two-fluid model with the suspension of all the erythrocytes in the core region as non-Newtonian fluid with yield stress and the plasma in the peripheral layer region as Newtonian. The non-Newtonian fluid with yield stress in the core region is assumed as �i� Herschel-Bulkley fluid and �ii� Casson fluid. The expressions for the shear stress, velocity, flow rate, wall shear stress, plug core radius, and longitudinal impedance to flow obtained by Sankar �2010� for two-fluidHerschel-Bulkleymodel and Sankar and Lee �2011� for two-fluid Casson model are used to compute the data for comparing these fluid models. It is observed that the plug core radius, wall shear stress, and longitudinal impedance to flow are lower for the two-fluid H-B model compared to the corresponding flow quantities of the two-fluid Casson model. It is noted that the plug core radius and longitudinal impedance to flow increases with the increase of the maximum depth of the stenosis. The mean velocity and mean flow rate of two-fluid H-B model are higher than those of the two-fluid Casson model. Hindawi Publishing Corporation 2012 Article PeerReviewed application/pdf en http://eprints.usm.my/38469/1/Comparative_Analysis_of_Mathematical_Models_for_Blood_Flow_in_Tapered_Constricted_Arteries.pdf Sankar, D. S. and Yatim, Yazariah (2012) Comparative Analysis of Mathematical Models for Blood Flow in Tapered Constricted Arteries. Abstract and Applied Analysis, 2012 (235960). pp. 1-34. ISSN 1085-3375 https://doi.org/10.1155/2012/235960
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic QA1-939 Mathematics
spellingShingle QA1-939 Mathematics
Sankar, D. S.
Yatim, Yazariah
Comparative Analysis of Mathematical Models for Blood Flow in Tapered Constricted Arteries
description Pulsatile flow of blood in narrow tapered arteries with mild overlapping stenosis in the presence of periodic body acceleration is analyzed mathematically, treating it as two-fluid model with the suspension of all the erythrocytes in the core region as non-Newtonian fluid with yield stress and the plasma in the peripheral layer region as Newtonian. The non-Newtonian fluid with yield stress in the core region is assumed as �i� Herschel-Bulkley fluid and �ii� Casson fluid. The expressions for the shear stress, velocity, flow rate, wall shear stress, plug core radius, and longitudinal impedance to flow obtained by Sankar �2010� for two-fluidHerschel-Bulkleymodel and Sankar and Lee �2011� for two-fluid Casson model are used to compute the data for comparing these fluid models. It is observed that the plug core radius, wall shear stress, and longitudinal impedance to flow are lower for the two-fluid H-B model compared to the corresponding flow quantities of the two-fluid Casson model. It is noted that the plug core radius and longitudinal impedance to flow increases with the increase of the maximum depth of the stenosis. The mean velocity and mean flow rate of two-fluid H-B model are higher than those of the two-fluid Casson model.
format Article
author Sankar, D. S.
Yatim, Yazariah
author_facet Sankar, D. S.
Yatim, Yazariah
author_sort Sankar, D. S.
title Comparative Analysis of Mathematical Models for Blood Flow in Tapered Constricted Arteries
title_short Comparative Analysis of Mathematical Models for Blood Flow in Tapered Constricted Arteries
title_full Comparative Analysis of Mathematical Models for Blood Flow in Tapered Constricted Arteries
title_fullStr Comparative Analysis of Mathematical Models for Blood Flow in Tapered Constricted Arteries
title_full_unstemmed Comparative Analysis of Mathematical Models for Blood Flow in Tapered Constricted Arteries
title_sort comparative analysis of mathematical models for blood flow in tapered constricted arteries
publisher Hindawi Publishing Corporation
publishDate 2012
url http://eprints.usm.my/38469/1/Comparative_Analysis_of_Mathematical_Models_for_Blood_Flow_in_Tapered_Constricted_Arteries.pdf
http://eprints.usm.my/38469/
https://doi.org/10.1155/2012/235960
_version_ 1643709366653681664
score 13.186907