Optimal Design Of Femoral Hip Prosthesis Using Topology Optimisation To Reduce Stress Shielding
Kemasukan implan ke dalam tulang paha telah mengurangkan agihan beban semulajadi kepada tulang. Introducing an implant into a femur might reduce the natural stress distribution of the femur
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Published: |
2005
|
Subjects: | |
Online Access: | http://eprints.usm.my/29634/1/Optimal_design_of_femoral_hip_prosthesis_using_topology_optimisation_to_reduce_stress_shielding.pdf http://eprints.usm.my/29634/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.usm.eprints.29634 |
---|---|
record_format |
eprints |
spelling |
my.usm.eprints.29634 http://eprints.usm.my/29634/ Optimal Design Of Femoral Hip Prosthesis Using Topology Optimisation To Reduce Stress Shielding Ridzwan, Mohamad Ikhwan Zaini QA75.5-76.95 Electronic computers. Computer science Kemasukan implan ke dalam tulang paha telah mengurangkan agihan beban semulajadi kepada tulang. Introducing an implant into a femur might reduce the natural stress distribution of the femur 2005-05 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/29634/1/Optimal_design_of_femoral_hip_prosthesis_using_topology_optimisation_to_reduce_stress_shielding.pdf Ridzwan, Mohamad Ikhwan Zaini (2005) Optimal Design Of Femoral Hip Prosthesis Using Topology Optimisation To Reduce Stress Shielding. Masters thesis, USM. |
institution |
Universiti Sains Malaysia |
building |
Hamzah Sendut Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Sains Malaysia |
content_source |
USM Institutional Repository |
url_provider |
http://eprints.usm.my/ |
language |
English |
topic |
QA75.5-76.95 Electronic computers. Computer science |
spellingShingle |
QA75.5-76.95 Electronic computers. Computer science Ridzwan, Mohamad Ikhwan Zaini Optimal Design Of Femoral Hip Prosthesis Using Topology Optimisation To Reduce Stress Shielding |
description |
Kemasukan implan ke dalam tulang paha telah mengurangkan agihan beban
semulajadi kepada tulang.
Introducing an implant into a femur might reduce the natural stress distribution of the
femur |
format |
Thesis |
author |
Ridzwan, Mohamad Ikhwan Zaini |
author_facet |
Ridzwan, Mohamad Ikhwan Zaini |
author_sort |
Ridzwan, Mohamad Ikhwan Zaini |
title |
Optimal Design Of Femoral Hip Prosthesis Using Topology
Optimisation To Reduce Stress Shielding |
title_short |
Optimal Design Of Femoral Hip Prosthesis Using Topology
Optimisation To Reduce Stress Shielding |
title_full |
Optimal Design Of Femoral Hip Prosthesis Using Topology
Optimisation To Reduce Stress Shielding |
title_fullStr |
Optimal Design Of Femoral Hip Prosthesis Using Topology
Optimisation To Reduce Stress Shielding |
title_full_unstemmed |
Optimal Design Of Femoral Hip Prosthesis Using Topology
Optimisation To Reduce Stress Shielding |
title_sort |
optimal design of femoral hip prosthesis using topology
optimisation to reduce stress shielding |
publishDate |
2005 |
url |
http://eprints.usm.my/29634/1/Optimal_design_of_femoral_hip_prosthesis_using_topology_optimisation_to_reduce_stress_shielding.pdf http://eprints.usm.my/29634/ |
_version_ |
1643706950859358208 |
score |
13.160551 |