Reaction of 2,6-dichloroquinone-4-chloroimide (Gibbs reagent) with permethrin - an optical sensor for rapid detection of permethrin in treated wood
Background: A novel optical sensor for the rapid and direct determination of permethrin preservatives in treated wood was designed. The optical sensor was fabricated from the immobilisation of 2,6-dichloro-p-benzoquinone-4-chloroimide (Gibbs reagent) in nafion/sol-gel hybrid film and the mode of det...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Biomed Central Ltd
2015
|
Subjects: | |
Online Access: | http://ddms.usim.edu.my/handle/123456789/8388 http://journal.chemistrycentral.com/content/pdf/1752-153X-7-122.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.usim-8388 |
---|---|
record_format |
dspace |
spelling |
my.usim-83882015-12-29T03:52:43Z Reaction of 2,6-dichloroquinone-4-chloroimide (Gibbs reagent) with permethrin - an optical sensor for rapid detection of permethrin in treated wood Mohamad Nasir, Mat Arip, Lee Yook, Heng, Siti Aishah, Hasbullah, Musa, Ahmad, Preservation Methods Composite Assay Background: A novel optical sensor for the rapid and direct determination of permethrin preservatives in treated wood was designed. The optical sensor was fabricated from the immobilisation of 2,6-dichloro-p-benzoquinone-4-chloroimide (Gibbs reagent) in nafion/sol-gel hybrid film and the mode of detection was based on absorption spectrophotometry. Physical entrapment was employed as a method of immobilisation. Results: The sensor gave a linear response range of permethrin between 2.56-383.00 mu M with detection limit of 2.5 mu M and demonstrated good repeatability with relative standard deviation (RSD) for 10 mu M at 5.3%, 100 mu M at 2.7%, and 200 mu M at 1.8%. The response time of the sensor was 40 s with an optimum response at pH 11. Conclusions: The sensor was useful for rapid screening of wood or treated wood products before detailed analysis using tedious procedure is performed. The validation study of the optical sensor against standard method HPLC successfully showed that the permethrin sensor tended to overestimate the permethrin concentration determined. 2015-06-16T03:46:09Z 2015-06-16T03:46:09Z 2013 Article 1752-153X http://ddms.usim.edu.my/handle/123456789/8388 http://journal.chemistrycentral.com/content/pdf/1752-153X-7-122.pdf en Biomed Central Ltd |
institution |
Universiti Sains Islam Malaysia |
building |
USIM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universit Sains Islam i Malaysia |
content_source |
USIM Institutional Repository |
url_provider |
http://ddms.usim.edu.my/ |
language |
English |
topic |
Preservation Methods Composite Assay |
spellingShingle |
Preservation Methods Composite Assay Mohamad Nasir, Mat Arip, Lee Yook, Heng, Siti Aishah, Hasbullah, Musa, Ahmad, Reaction of 2,6-dichloroquinone-4-chloroimide (Gibbs reagent) with permethrin - an optical sensor for rapid detection of permethrin in treated wood |
description |
Background: A novel optical sensor for the rapid and direct determination of permethrin preservatives in treated wood was designed. The optical sensor was fabricated from the immobilisation of 2,6-dichloro-p-benzoquinone-4-chloroimide (Gibbs reagent) in nafion/sol-gel hybrid film and the mode of detection was based on absorption spectrophotometry. Physical entrapment was employed as a method of immobilisation. Results: The sensor gave a linear response range of permethrin between 2.56-383.00 mu M with detection limit of 2.5 mu M and demonstrated good repeatability with relative standard deviation (RSD) for 10 mu M at 5.3%, 100 mu M at 2.7%, and 200 mu M at 1.8%. The response time of the sensor was 40 s with an optimum response at pH 11. Conclusions: The sensor was useful for rapid screening of wood or treated wood products before detailed analysis using tedious procedure is performed. The validation study of the optical sensor against standard method HPLC successfully showed that the permethrin sensor tended to overestimate the permethrin concentration determined. |
format |
Article |
author |
Mohamad Nasir, Mat Arip, Lee Yook, Heng, Siti Aishah, Hasbullah, Musa, Ahmad, |
author_facet |
Mohamad Nasir, Mat Arip, Lee Yook, Heng, Siti Aishah, Hasbullah, Musa, Ahmad, |
author_sort |
Mohamad Nasir, Mat Arip, |
title |
Reaction of 2,6-dichloroquinone-4-chloroimide (Gibbs reagent) with permethrin - an optical sensor for rapid detection of permethrin in treated wood |
title_short |
Reaction of 2,6-dichloroquinone-4-chloroimide (Gibbs reagent) with permethrin - an optical sensor for rapid detection of permethrin in treated wood |
title_full |
Reaction of 2,6-dichloroquinone-4-chloroimide (Gibbs reagent) with permethrin - an optical sensor for rapid detection of permethrin in treated wood |
title_fullStr |
Reaction of 2,6-dichloroquinone-4-chloroimide (Gibbs reagent) with permethrin - an optical sensor for rapid detection of permethrin in treated wood |
title_full_unstemmed |
Reaction of 2,6-dichloroquinone-4-chloroimide (Gibbs reagent) with permethrin - an optical sensor for rapid detection of permethrin in treated wood |
title_sort |
reaction of 2,6-dichloroquinone-4-chloroimide (gibbs reagent) with permethrin - an optical sensor for rapid detection of permethrin in treated wood |
publisher |
Biomed Central Ltd |
publishDate |
2015 |
url |
http://ddms.usim.edu.my/handle/123456789/8388 http://journal.chemistrycentral.com/content/pdf/1752-153X-7-122.pdf |
_version_ |
1645152407539154944 |
score |
13.214268 |