G-quadruplex microspheres-based optical RNA biosensor for arthropod-borne virus pathogen detection: A proof-of-concept with dengue serotype 2

Dengue virus (DENV) is a positive-sense single-stranded RNA virus and that the detection of viral RNA itself is highly desirable, which can be achieved by using RNA biosensor diagnostic method. Herein, acrylic micropolymer-based optical RNA biosensor was developed by binding anionic copper(II) phtha...

Full description

Saved in:
Bibliographic Details
Main Authors: Jamaluddin, Nur Diyana, Mazlan, Nur-Fadhilah, Tan, Ling Ling, Mohd Yusof, Nurul Yuziana, Khalid, Bahariah
Format: Article
Language:English
Published: Elsevier 2021
Online Access:http://psasir.upm.edu.my/id/eprint/97466/1/ABSTRACT.pdf
http://psasir.upm.edu.my/id/eprint/97466/
https://www.sciencedirect.com/science/article/pii/S0141813021026702
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.97466
record_format eprints
spelling my.upm.eprints.974662022-07-27T04:29:21Z http://psasir.upm.edu.my/id/eprint/97466/ G-quadruplex microspheres-based optical RNA biosensor for arthropod-borne virus pathogen detection: A proof-of-concept with dengue serotype 2 Jamaluddin, Nur Diyana Mazlan, Nur-Fadhilah Tan, Ling Ling Mohd Yusof, Nurul Yuziana Khalid, Bahariah Dengue virus (DENV) is a positive-sense single-stranded RNA virus and that the detection of viral RNA itself is highly desirable, which can be achieved by using RNA biosensor diagnostic method. Herein, acrylic micropolymer-based optical RNA biosensor was developed by binding anionic copper(II) phthalocyanine (CPC) planar aromatic ligand to the G-quadruplex DNA probe via end-stacking with π-system of the guanine (G) quartet, and a blue coloration was developed on the G-quadruplex microspheres. Hybridization of G-quadruplex DNA probe with target DENV serotype 2 (DENV2) RNA unfolded the G-quadruplex, and rendering release of the CPC planar optical label, causing discoloration of the G-quadruplex microbiosensor. Optical characterization of the RNA biosensor was performed by means of fiber optic reflectance spectrophotometer at maximum reflectance wavelength of 774 nm. The reflectance response enhancement of the RNA-responsive G-quadruplex-based reflectometric biosensor was linearly proportional to the target oligo DENV2 RNA concentration in the range of 2 zM–2 μM, with a 0.447 zM limit of detection and a rapid response time of 30 min. Heightening in the reflectance signal based on structural transition of G-quadruplex in response to target RNA was successfully implemented in real-time DENV2 detection in non-invasive human fluid samples (i.e. saliva and urine) under informed consent. Elsevier 2021 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/97466/1/ABSTRACT.pdf Jamaluddin, Nur Diyana and Mazlan, Nur-Fadhilah and Tan, Ling Ling and Mohd Yusof, Nurul Yuziana and Khalid, Bahariah (2021) G-quadruplex microspheres-based optical RNA biosensor for arthropod-borne virus pathogen detection: A proof-of-concept with dengue serotype 2. International Journal of Biological Macromolecules, 199 (2022). pp. 1-9. ISSN 0141-8130 (Submitted) https://www.sciencedirect.com/science/article/pii/S0141813021026702 10.1016/j.ijbiomac.2021.12.047
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description Dengue virus (DENV) is a positive-sense single-stranded RNA virus and that the detection of viral RNA itself is highly desirable, which can be achieved by using RNA biosensor diagnostic method. Herein, acrylic micropolymer-based optical RNA biosensor was developed by binding anionic copper(II) phthalocyanine (CPC) planar aromatic ligand to the G-quadruplex DNA probe via end-stacking with π-system of the guanine (G) quartet, and a blue coloration was developed on the G-quadruplex microspheres. Hybridization of G-quadruplex DNA probe with target DENV serotype 2 (DENV2) RNA unfolded the G-quadruplex, and rendering release of the CPC planar optical label, causing discoloration of the G-quadruplex microbiosensor. Optical characterization of the RNA biosensor was performed by means of fiber optic reflectance spectrophotometer at maximum reflectance wavelength of 774 nm. The reflectance response enhancement of the RNA-responsive G-quadruplex-based reflectometric biosensor was linearly proportional to the target oligo DENV2 RNA concentration in the range of 2 zM–2 μM, with a 0.447 zM limit of detection and a rapid response time of 30 min. Heightening in the reflectance signal based on structural transition of G-quadruplex in response to target RNA was successfully implemented in real-time DENV2 detection in non-invasive human fluid samples (i.e. saliva and urine) under informed consent.
format Article
author Jamaluddin, Nur Diyana
Mazlan, Nur-Fadhilah
Tan, Ling Ling
Mohd Yusof, Nurul Yuziana
Khalid, Bahariah
spellingShingle Jamaluddin, Nur Diyana
Mazlan, Nur-Fadhilah
Tan, Ling Ling
Mohd Yusof, Nurul Yuziana
Khalid, Bahariah
G-quadruplex microspheres-based optical RNA biosensor for arthropod-borne virus pathogen detection: A proof-of-concept with dengue serotype 2
author_facet Jamaluddin, Nur Diyana
Mazlan, Nur-Fadhilah
Tan, Ling Ling
Mohd Yusof, Nurul Yuziana
Khalid, Bahariah
author_sort Jamaluddin, Nur Diyana
title G-quadruplex microspheres-based optical RNA biosensor for arthropod-borne virus pathogen detection: A proof-of-concept with dengue serotype 2
title_short G-quadruplex microspheres-based optical RNA biosensor for arthropod-borne virus pathogen detection: A proof-of-concept with dengue serotype 2
title_full G-quadruplex microspheres-based optical RNA biosensor for arthropod-borne virus pathogen detection: A proof-of-concept with dengue serotype 2
title_fullStr G-quadruplex microspheres-based optical RNA biosensor for arthropod-borne virus pathogen detection: A proof-of-concept with dengue serotype 2
title_full_unstemmed G-quadruplex microspheres-based optical RNA biosensor for arthropod-borne virus pathogen detection: A proof-of-concept with dengue serotype 2
title_sort g-quadruplex microspheres-based optical rna biosensor for arthropod-borne virus pathogen detection: a proof-of-concept with dengue serotype 2
publisher Elsevier
publishDate 2021
url http://psasir.upm.edu.my/id/eprint/97466/1/ABSTRACT.pdf
http://psasir.upm.edu.my/id/eprint/97466/
https://www.sciencedirect.com/science/article/pii/S0141813021026702
_version_ 1739829901861584896
score 13.251813