Transient fault detection and location in power distribution network: a review of current practices and challenges in Malaysia

An auto-restoration tool to minimize the impact of faults is one of the critical requirements in a power distribution system. A fault-monitoring system is needed for practical remote supervision to identify faults and reduce their impacts, and thus reduce economic losses. An effective fault-monitori...

Full description

Saved in:
Bibliographic Details
Main Authors: Asman, Saidatul Habsah, Ab Aziz, Nur Fadilah, Ungku Amirulddin Al Amin, Ungku Anisa, Ab Kadir, Mohd Zainal Abidin
Format: Article
Published: MDPI 2021
Online Access:http://psasir.upm.edu.my/id/eprint/93420/
https://www.mdpi.com/1996-1073/14/11/2988
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.93420
record_format eprints
spelling my.upm.eprints.934202023-01-12T06:26:14Z http://psasir.upm.edu.my/id/eprint/93420/ Transient fault detection and location in power distribution network: a review of current practices and challenges in Malaysia Asman, Saidatul Habsah Ab Aziz, Nur Fadilah Ungku Amirulddin Al Amin, Ungku Anisa Ab Kadir, Mohd Zainal Abidin An auto-restoration tool to minimize the impact of faults is one of the critical requirements in a power distribution system. A fault-monitoring system is needed for practical remote supervision to identify faults and reduce their impacts, and thus reduce economic losses. An effective fault-monitoring system is beneficial to improve the reliability of a protection system when faults evolve. Therefore, fault monitoring could play an important role in enhancing the safety standards of systems. Among the various fault occurrences, the transient fault is a prominent cause in Malaysia power systems but gains less attention due to its ability of self-clearance, although sometimes it unnecessarily triggers the operation of protection systems. However, the transient fault is an issue that must be addressed based on its effect that can lead to outages and short-circuits if prolonged. In this study, the authors summarize the guidelines and related standards of fault interaction associated with a monitoring system. The necessity of transient fault detection and location techniques and their limitations, the need for signal processing, as well as recommended practices, are also discussed in this paper. Some of the practices from local power utility are also shared, indicating the current approaches, key challenges, and the opportunities for improvement of fault-monitoring systems due to transient fault, which can be correlated with the reviews provided. MDPI 2021-05-21 Article PeerReviewed Asman, Saidatul Habsah and Ab Aziz, Nur Fadilah and Ungku Amirulddin Al Amin, Ungku Anisa and Ab Kadir, Mohd Zainal Abidin (2021) Transient fault detection and location in power distribution network: a review of current practices and challenges in Malaysia. Energies, 14 (11). pp. 1-37. ISSN 1996-1073 https://www.mdpi.com/1996-1073/14/11/2988 10.3390/en14112988
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
description An auto-restoration tool to minimize the impact of faults is one of the critical requirements in a power distribution system. A fault-monitoring system is needed for practical remote supervision to identify faults and reduce their impacts, and thus reduce economic losses. An effective fault-monitoring system is beneficial to improve the reliability of a protection system when faults evolve. Therefore, fault monitoring could play an important role in enhancing the safety standards of systems. Among the various fault occurrences, the transient fault is a prominent cause in Malaysia power systems but gains less attention due to its ability of self-clearance, although sometimes it unnecessarily triggers the operation of protection systems. However, the transient fault is an issue that must be addressed based on its effect that can lead to outages and short-circuits if prolonged. In this study, the authors summarize the guidelines and related standards of fault interaction associated with a monitoring system. The necessity of transient fault detection and location techniques and their limitations, the need for signal processing, as well as recommended practices, are also discussed in this paper. Some of the practices from local power utility are also shared, indicating the current approaches, key challenges, and the opportunities for improvement of fault-monitoring systems due to transient fault, which can be correlated with the reviews provided.
format Article
author Asman, Saidatul Habsah
Ab Aziz, Nur Fadilah
Ungku Amirulddin Al Amin, Ungku Anisa
Ab Kadir, Mohd Zainal Abidin
spellingShingle Asman, Saidatul Habsah
Ab Aziz, Nur Fadilah
Ungku Amirulddin Al Amin, Ungku Anisa
Ab Kadir, Mohd Zainal Abidin
Transient fault detection and location in power distribution network: a review of current practices and challenges in Malaysia
author_facet Asman, Saidatul Habsah
Ab Aziz, Nur Fadilah
Ungku Amirulddin Al Amin, Ungku Anisa
Ab Kadir, Mohd Zainal Abidin
author_sort Asman, Saidatul Habsah
title Transient fault detection and location in power distribution network: a review of current practices and challenges in Malaysia
title_short Transient fault detection and location in power distribution network: a review of current practices and challenges in Malaysia
title_full Transient fault detection and location in power distribution network: a review of current practices and challenges in Malaysia
title_fullStr Transient fault detection and location in power distribution network: a review of current practices and challenges in Malaysia
title_full_unstemmed Transient fault detection and location in power distribution network: a review of current practices and challenges in Malaysia
title_sort transient fault detection and location in power distribution network: a review of current practices and challenges in malaysia
publisher MDPI
publishDate 2021
url http://psasir.upm.edu.my/id/eprint/93420/
https://www.mdpi.com/1996-1073/14/11/2988
_version_ 1755873895039107072
score 13.211869