Thermal diffusivity measurement using photoacoustic and thermal lens techniques

The open photoacoustic cell (OPC) technique was used for measuring thermal diffusivity of solid samples. It is based upon the measurement of the photoacoustic signal as a function of the modulation frequency in the region where the thermal diffusion length equals to the-sample thickness. The meas...

Full description

Saved in:
Bibliographic Details
Main Author: Chin, Fanny Yee Ju
Format: Thesis
Language:English
English
Published: 2000
Subjects:
Online Access:http://psasir.upm.edu.my/id/eprint/9105/1/FSAS_2000_30%20IR.pdf
http://psasir.upm.edu.my/id/eprint/9105/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.9105
record_format eprints
spelling my.upm.eprints.91052024-03-27T04:46:51Z http://psasir.upm.edu.my/id/eprint/9105/ Thermal diffusivity measurement using photoacoustic and thermal lens techniques Chin, Fanny Yee Ju The open photoacoustic cell (OPC) technique was used for measuring thermal diffusivity of solid samples. It is based upon the measurement of the photoacoustic signal as a function of the modulation frequency in the region where the thermal diffusion length equals to the-sample thickness. The measurements were carried out at room temperature for samples metal, alloy, semiconductor, polymer and superconductor. The measured thermal diffusivity values for metal, semiconductor and polymer samples are in good agreement with the values reported previously by other researchers. The thermal diffusivity values of the AgxAu1-x alloys decrease from 1.48 cm2/s (pure Ag) to a minimum value at around x = 0.70 before increasing towards the value of 1.28 cm2/s (pure Au). In AuxCu(l00-x)07Ag(l00-x)O.3 alloy system, the thermal diffusivity values decrease with the increasing of the weight fraction x and reaching a minimum at around x = 90 composition. Then, the thermal diffusivity values tend to increase to the value of 1.28 cm2/s for the pure Au metal. For superconductor samples in the normal state, the measured thermal diffusivity decreases with the increase of Zn content in the BbPbo.6Sr2Ca2-xZnxCu30o system, However, the thermal diffusivity values increase with the increasing of Ba dopant in the Bi2Pbo.6Sr2Ca2-xBaxCu30o system. The OPC detection was also used to monitor the evaporation time of the liquid samples. The evaporation time for 10.60 mm3 of acetone, chloroform, methanol and ethanol samples were recorded as 236.7s, 578.8s, 436.2s and 869.2s respectively. The results also show that the liquid evaporation time is inversely proportional to the laser power. The laser beam power in the range of (2-16) m W was monitored by using OPC, closed photoacoustic cell (CPC) and piezoelectric (PZT) detections. In each case, the photoacoustic (PA) signals were found to be linear up to the laser power of 16 m W. In comparison, the power meter responsivity for CPC detection always higher than OPC and followed by PZT detection. Finally, the thermal lens technique was used to determine the thermal diffusivity of liquid samples. The phenomenon of thermal lensing is due to the refractive index change with temperature in a liquid medium causes by the periodic photothermal heating. The change of the refractive index will turn the heated medium into a lens. By measuring the time dependence of the laser intensity change after passed though the thermal lens, the thermal diffusivity of the sample can be obtained. In this work, the measurements were carried out for various solvents, fuel, palm oils and chitosan at different concentration. It was found that the thermal lens technique was suitable for measuring thermal diffusivity value of liquids in the range of (9.09 x 10-4 - 12. 1 X 10-4) cm2/s. 2000-05 Thesis NonPeerReviewed text en http://psasir.upm.edu.my/id/eprint/9105/1/FSAS_2000_30%20IR.pdf Chin, Fanny Yee Ju (2000) Thermal diffusivity measurement using photoacoustic and thermal lens techniques. Masters thesis, Universiti Putra Malaysia. Thermal diffusivity - Measurements Optoacoustic spectroscopy English
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
English
topic Thermal diffusivity - Measurements
Optoacoustic spectroscopy
spellingShingle Thermal diffusivity - Measurements
Optoacoustic spectroscopy
Chin, Fanny Yee Ju
Thermal diffusivity measurement using photoacoustic and thermal lens techniques
description The open photoacoustic cell (OPC) technique was used for measuring thermal diffusivity of solid samples. It is based upon the measurement of the photoacoustic signal as a function of the modulation frequency in the region where the thermal diffusion length equals to the-sample thickness. The measurements were carried out at room temperature for samples metal, alloy, semiconductor, polymer and superconductor. The measured thermal diffusivity values for metal, semiconductor and polymer samples are in good agreement with the values reported previously by other researchers. The thermal diffusivity values of the AgxAu1-x alloys decrease from 1.48 cm2/s (pure Ag) to a minimum value at around x = 0.70 before increasing towards the value of 1.28 cm2/s (pure Au). In AuxCu(l00-x)07Ag(l00-x)O.3 alloy system, the thermal diffusivity values decrease with the increasing of the weight fraction x and reaching a minimum at around x = 90 composition. Then, the thermal diffusivity values tend to increase to the value of 1.28 cm2/s for the pure Au metal. For superconductor samples in the normal state, the measured thermal diffusivity decreases with the increase of Zn content in the BbPbo.6Sr2Ca2-xZnxCu30o system, However, the thermal diffusivity values increase with the increasing of Ba dopant in the Bi2Pbo.6Sr2Ca2-xBaxCu30o system. The OPC detection was also used to monitor the evaporation time of the liquid samples. The evaporation time for 10.60 mm3 of acetone, chloroform, methanol and ethanol samples were recorded as 236.7s, 578.8s, 436.2s and 869.2s respectively. The results also show that the liquid evaporation time is inversely proportional to the laser power. The laser beam power in the range of (2-16) m W was monitored by using OPC, closed photoacoustic cell (CPC) and piezoelectric (PZT) detections. In each case, the photoacoustic (PA) signals were found to be linear up to the laser power of 16 m W. In comparison, the power meter responsivity for CPC detection always higher than OPC and followed by PZT detection. Finally, the thermal lens technique was used to determine the thermal diffusivity of liquid samples. The phenomenon of thermal lensing is due to the refractive index change with temperature in a liquid medium causes by the periodic photothermal heating. The change of the refractive index will turn the heated medium into a lens. By measuring the time dependence of the laser intensity change after passed though the thermal lens, the thermal diffusivity of the sample can be obtained. In this work, the measurements were carried out for various solvents, fuel, palm oils and chitosan at different concentration. It was found that the thermal lens technique was suitable for measuring thermal diffusivity value of liquids in the range of (9.09 x 10-4 - 12. 1 X 10-4) cm2/s.
format Thesis
author Chin, Fanny Yee Ju
author_facet Chin, Fanny Yee Ju
author_sort Chin, Fanny Yee Ju
title Thermal diffusivity measurement using photoacoustic and thermal lens techniques
title_short Thermal diffusivity measurement using photoacoustic and thermal lens techniques
title_full Thermal diffusivity measurement using photoacoustic and thermal lens techniques
title_fullStr Thermal diffusivity measurement using photoacoustic and thermal lens techniques
title_full_unstemmed Thermal diffusivity measurement using photoacoustic and thermal lens techniques