Catheter-related infections and microbiological characteristics in coiled versus straight peritoneal dialysis catheters in Malaysia
Background: Catheter-related infections remain a threat in peritoneal dialysis (PD) patients. Attempts to improve catheter insertion techniques and catheter type with best infectious outcomes yield heterogenous results. We seek to determine catheter-related infections in two different types of cathe...
Saved in:
Main Authors: | Abdul Rashid, Anna Misya'il, Lim, Christopher Thiam Seong |
---|---|
Format: | Article |
Language: | English |
Published: |
Medknow Publications
2020
|
Online Access: | http://psasir.upm.edu.my/id/eprint/88097/1/ABSTRACT.pdf http://psasir.upm.edu.my/id/eprint/88097/ https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8722545/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
Peritoneal dialysis catheter insertion techniques by the nephrologist
by: Goh, Bak Leong, et al.
Published: (2024) -
Enterobacter gergoviae peritonitis in a patient on chronic ambulatory peritoneal dialysis - first reported case
by: Abdul Rashid, Anna Misya'il, et al.
Published: (2017) -
Pregnancy and peritoneal dialysis: an updated review
by: Thiam, Christopher Seong Lim, et al.
Published: (2018) -
A rare case of streptococcus gordonii peritonitis in a patient on peritoneal dialysis
by: Lim, Christopher Thiam Seong, et al.
Published: (2017) -
Acute hydrothorax from peritoneal dialysis successfully treated with new dialysis regime
by: Lim, Christopher Thiam Seong, et al.
Published: (2015)