Development of sandwich and label-free electrochemical immunosensor for detection of HER2 breast cancer biomarker

An electrochemical immunosensor for determination of HER2 biomarker was developed using two different types of immunoreaction, which are label-free and sandwich assay. The fabrication of label-free immunosensor involved several steps; (1) pre-treatment of screen printed carbon electrode (SPCE) (2) t...

Full description

Saved in:
Bibliographic Details
Main Author: Lah, Zur Mira Azizah @ Nor Haiza
Format: Thesis
Language:English
Published: 2018
Subjects:
Online Access:http://psasir.upm.edu.my/id/eprint/83184/1/FS%202019%2072%20ir.pdf
http://psasir.upm.edu.my/id/eprint/83184/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.83184
record_format eprints
spelling my.upm.eprints.831842022-01-10T03:26:22Z http://psasir.upm.edu.my/id/eprint/83184/ Development of sandwich and label-free electrochemical immunosensor for detection of HER2 breast cancer biomarker Lah, Zur Mira Azizah @ Nor Haiza An electrochemical immunosensor for determination of HER2 biomarker was developed using two different types of immunoreaction, which are label-free and sandwich assay. The fabrication of label-free immunosensor involved several steps; (1) pre-treatment of screen printed carbon electrode (SPCE) (2) the binding of primary anti-HER2 antibody to pre-treated SPCE via EDC/NHS (3) bovine serum albumin (BSA) blocking (4) the binding of HER2 antigen (5) electroanalytical performance of the label-free immunosensor. While, in sandwich immunosensor, lead sulphide quantum dots coated with secondary antibodies (Ab2-PbS QDs) were used as a label and the fabrication involved additional several steps which were; (1) synthesis and bioconjugation of PbS QDs with secondary onto-HER2 antibody (2) the sandwich of Ab2-PbS QDs onto label-free immunosensor (3) acid dissolution of Pb2+ from label and detection via square wave voltammetry (SWV). The electrochemical properties of the developed immunosensors were analysed by cyclic voltammetry (CV) and electron impedance spectroscopy (EIS) using Fe(CN)6 -3/-4 as a redox probe. Under optimal condition, label-free and sandwich immunosensors were assessed by using differential pulse voltammetry (DPV) and SWV, respectively. The analytical performances revealed that both immunosensor give satisfactory sensitivity, selectivity and reproducibility towards HER2 cancer biomarker. For a linear range of 0.04- 2.0 ng/ml of label-free immunosensor, the limit of detection obtained was 0.01 ng/ml while for sandwich immunosensor, the limit of detection obtained was 1.1 ng/ml for a linear range of 2.0-10 ng/ml Furthermore, excellent recovery also obtained in human serum sample for both label-free and sandwich immunosensor. It was discovered that the recovery percentage of HER2 antigen in sandwich immunosensor was 102.06 % with RSD percentage of 7.51 %, while for label-free immunosensor, the percentage recovery is 97.10 % with RSD percentage of 10.89 %. 2018-08 Thesis NonPeerReviewed text en http://psasir.upm.edu.my/id/eprint/83184/1/FS%202019%2072%20ir.pdf Lah, Zur Mira Azizah @ Nor Haiza (2018) Development of sandwich and label-free electrochemical immunosensor for detection of HER2 breast cancer biomarker. Masters thesis, Universiti Putra Malaysia. Electrochemical sensors Tumor markers
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
topic Electrochemical sensors
Tumor markers
spellingShingle Electrochemical sensors
Tumor markers
Lah, Zur Mira Azizah @ Nor Haiza
Development of sandwich and label-free electrochemical immunosensor for detection of HER2 breast cancer biomarker
description An electrochemical immunosensor for determination of HER2 biomarker was developed using two different types of immunoreaction, which are label-free and sandwich assay. The fabrication of label-free immunosensor involved several steps; (1) pre-treatment of screen printed carbon electrode (SPCE) (2) the binding of primary anti-HER2 antibody to pre-treated SPCE via EDC/NHS (3) bovine serum albumin (BSA) blocking (4) the binding of HER2 antigen (5) electroanalytical performance of the label-free immunosensor. While, in sandwich immunosensor, lead sulphide quantum dots coated with secondary antibodies (Ab2-PbS QDs) were used as a label and the fabrication involved additional several steps which were; (1) synthesis and bioconjugation of PbS QDs with secondary onto-HER2 antibody (2) the sandwich of Ab2-PbS QDs onto label-free immunosensor (3) acid dissolution of Pb2+ from label and detection via square wave voltammetry (SWV). The electrochemical properties of the developed immunosensors were analysed by cyclic voltammetry (CV) and electron impedance spectroscopy (EIS) using Fe(CN)6 -3/-4 as a redox probe. Under optimal condition, label-free and sandwich immunosensors were assessed by using differential pulse voltammetry (DPV) and SWV, respectively. The analytical performances revealed that both immunosensor give satisfactory sensitivity, selectivity and reproducibility towards HER2 cancer biomarker. For a linear range of 0.04- 2.0 ng/ml of label-free immunosensor, the limit of detection obtained was 0.01 ng/ml while for sandwich immunosensor, the limit of detection obtained was 1.1 ng/ml for a linear range of 2.0-10 ng/ml Furthermore, excellent recovery also obtained in human serum sample for both label-free and sandwich immunosensor. It was discovered that the recovery percentage of HER2 antigen in sandwich immunosensor was 102.06 % with RSD percentage of 7.51 %, while for label-free immunosensor, the percentage recovery is 97.10 % with RSD percentage of 10.89 %.
format Thesis
author Lah, Zur Mira Azizah @ Nor Haiza
author_facet Lah, Zur Mira Azizah @ Nor Haiza
author_sort Lah, Zur Mira Azizah @ Nor Haiza
title Development of sandwich and label-free electrochemical immunosensor for detection of HER2 breast cancer biomarker
title_short Development of sandwich and label-free electrochemical immunosensor for detection of HER2 breast cancer biomarker
title_full Development of sandwich and label-free electrochemical immunosensor for detection of HER2 breast cancer biomarker
title_fullStr Development of sandwich and label-free electrochemical immunosensor for detection of HER2 breast cancer biomarker
title_full_unstemmed Development of sandwich and label-free electrochemical immunosensor for detection of HER2 breast cancer biomarker
title_sort development of sandwich and label-free electrochemical immunosensor for detection of her2 breast cancer biomarker
publishDate 2018
url http://psasir.upm.edu.my/id/eprint/83184/1/FS%202019%2072%20ir.pdf
http://psasir.upm.edu.my/id/eprint/83184/
_version_ 1724075374760951808
score 13.15806