Ventilation Parameters and Thermal Comfort of Naturally and Mechanically Ventilated Offices

This paper discusses thermal comfort for a postgraduate study office room in the Mechanical Engineering Department of University Putra Malaysia (UPM), which maybe either naturally ventilated or air-conditioned. Thermal comfort variables were assessed by survey of sensation of the indoor climate. Tra...

Full description

Saved in:
Bibliographic Details
Main Authors: Daghigh, Roonak, Adam, Nor Mariah, Sahari, Barkawi
Format: Article
Language:English
English
Published: SAGE Publications 2009
Online Access:http://psasir.upm.edu.my/id/eprint/8237/1/Ventilation%20Parameters%20and%20Thermal%20Comfort%20of%20Naturally%20and%20Mechanically%20Ventilated%20Offices.pdf
http://psasir.upm.edu.my/id/eprint/8237/
http://dx.doi.org/10.1177/1420326X09103013
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.8237
record_format eprints
spelling my.upm.eprints.82372015-11-12T03:58:47Z http://psasir.upm.edu.my/id/eprint/8237/ Ventilation Parameters and Thermal Comfort of Naturally and Mechanically Ventilated Offices Daghigh, Roonak Adam, Nor Mariah Sahari, Barkawi This paper discusses thermal comfort for a postgraduate study office room in the Mechanical Engineering Department of University Putra Malaysia (UPM), which maybe either naturally ventilated or air-conditioned. Thermal comfort variables were assessed by survey of sensation of the indoor climate. Tracer gas analysis, based on the concentration decay method, was employed to determine air exchange rate, age of air, and air exchange effectiveness (AEE). When the air conditioner was working the study office had conditions within the comfort zone of the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Standard 55; and the occupants reported they were "slightly cool." Objective data analysis showed that the office was thermally comfortable. Under naturally ventilated conditions objective results showed that the office was uncomfortable but a subjective study revealed that students found the conditions to be "slightly warm." The neutral temperature showed a wider thermal comfort range for Malaysian students than that suggested by ASHRAE Standard 55-1992, which indicates that Malaysians are acclimatized to higher environmental temperatures. However, the result is in line with the current version of ASHRAE Standard 55-2004 that includes an adaptive comfort standard that allows warmer indoor temperatures for warmer climate zones. The results of a ventilation study indicated air flow patterns in the occupied zones, which approximated to "perfect mixing" under both ventilation conditions. The measured air exchange rate also indicated that the provision of outside air for ventilation was adequate when the room was mechanically ventilated (air-conditioned). Results of over 50 survey responses to thermal comfort questions in the study room at UPM are given. SAGE Publications 2009 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/8237/1/Ventilation%20Parameters%20and%20Thermal%20Comfort%20of%20Naturally%20and%20Mechanically%20Ventilated%20Offices.pdf Daghigh, Roonak and Adam, Nor Mariah and Sahari, Barkawi (2009) Ventilation Parameters and Thermal Comfort of Naturally and Mechanically Ventilated Offices. Indoor and Built Environment, 18 (2). pp. 113-122. ISSN 1420-326X http://dx.doi.org/10.1177/1420326X09103013 10.1177/1420326X09103013 English
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
English
description This paper discusses thermal comfort for a postgraduate study office room in the Mechanical Engineering Department of University Putra Malaysia (UPM), which maybe either naturally ventilated or air-conditioned. Thermal comfort variables were assessed by survey of sensation of the indoor climate. Tracer gas analysis, based on the concentration decay method, was employed to determine air exchange rate, age of air, and air exchange effectiveness (AEE). When the air conditioner was working the study office had conditions within the comfort zone of the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Standard 55; and the occupants reported they were "slightly cool." Objective data analysis showed that the office was thermally comfortable. Under naturally ventilated conditions objective results showed that the office was uncomfortable but a subjective study revealed that students found the conditions to be "slightly warm." The neutral temperature showed a wider thermal comfort range for Malaysian students than that suggested by ASHRAE Standard 55-1992, which indicates that Malaysians are acclimatized to higher environmental temperatures. However, the result is in line with the current version of ASHRAE Standard 55-2004 that includes an adaptive comfort standard that allows warmer indoor temperatures for warmer climate zones. The results of a ventilation study indicated air flow patterns in the occupied zones, which approximated to "perfect mixing" under both ventilation conditions. The measured air exchange rate also indicated that the provision of outside air for ventilation was adequate when the room was mechanically ventilated (air-conditioned). Results of over 50 survey responses to thermal comfort questions in the study room at UPM are given.
format Article
author Daghigh, Roonak
Adam, Nor Mariah
Sahari, Barkawi
spellingShingle Daghigh, Roonak
Adam, Nor Mariah
Sahari, Barkawi
Ventilation Parameters and Thermal Comfort of Naturally and Mechanically Ventilated Offices
author_facet Daghigh, Roonak
Adam, Nor Mariah
Sahari, Barkawi
author_sort Daghigh, Roonak
title Ventilation Parameters and Thermal Comfort of Naturally and Mechanically Ventilated Offices
title_short Ventilation Parameters and Thermal Comfort of Naturally and Mechanically Ventilated Offices
title_full Ventilation Parameters and Thermal Comfort of Naturally and Mechanically Ventilated Offices
title_fullStr Ventilation Parameters and Thermal Comfort of Naturally and Mechanically Ventilated Offices
title_full_unstemmed Ventilation Parameters and Thermal Comfort of Naturally and Mechanically Ventilated Offices
title_sort ventilation parameters and thermal comfort of naturally and mechanically ventilated offices
publisher SAGE Publications
publishDate 2009
url http://psasir.upm.edu.my/id/eprint/8237/1/Ventilation%20Parameters%20and%20Thermal%20Comfort%20of%20Naturally%20and%20Mechanically%20Ventilated%20Offices.pdf
http://psasir.upm.edu.my/id/eprint/8237/
http://dx.doi.org/10.1177/1420326X09103013
_version_ 1643823958604120064
score 13.18916