Ge-doped silica fibre proton beam measurements: thermoluminescence dose-response and glow curve characteristics

Present investigations concern germanium (Ge) doped (2.3 and 6.0 mol%) silica preforms fabricated into cylindrical- and flat-shaped fibre radiation dosimeters. When subjected to 150-MeV proton beam irradiation, the fibres are observed to produce sensitive dose response. The fibres are fabricated...

Full description

Saved in:
Bibliographic Details
Main Authors: Hassan, M. F., Rahman, W. N. W. A., Kadir, A. B. A., Isa, N. M., Tominaga, T., Geso, M., Akasaka, H., Bradley, D. A., Noor, N. M.
Format: Article
Published: Universiti Malaysia Perlis 2019
Online Access:http://psasir.upm.edu.my/id/eprint/79972/
https://ijneam.unimap.edu.my/index.php/vol-11-dec-2018-special-issue-bond21