Frequency response of transformer winding to investigate the influence of RLC

Frequency response measurements are used for power transformer winding failures detection. The variation between frequency responses indicate mechanical changes in the transformer winding. One method to investigate winding failures in transformer is to develop a reliable circuit model which can simu...

Full description

Saved in:
Bibliographic Details
Main Authors: Al-Ameri, S., Yousof, M. F. M., Azis, Norhafiz, Avinash S., Talib, M. A., Salem, Ali. A.
Format: Article
Published: Institute of Advanced Engineering and Science 2019
Online Access:http://psasir.upm.edu.my/id/eprint/79952/
https://ijeecs.iaescore.com/index.php/IJEECS/article/view/16791
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.79952
record_format eprints
spelling my.upm.eprints.799522023-04-03T02:39:39Z http://psasir.upm.edu.my/id/eprint/79952/ Frequency response of transformer winding to investigate the influence of RLC Al-Ameri, S. Yousof, M. F. M. Azis, Norhafiz Avinash S. Talib, M. A. Salem, Ali. A. Frequency response measurements are used for power transformer winding failures detection. The variation between frequency responses indicate mechanical changes in the transformer winding. One method to investigate winding failures in transformer is to develop a reliable circuit model which can simulate the frequency response of an actual winding. The main reason to use the model is because it is expensive to create damages on an actual winding. This paper proposes n-stages circuit ladder network to simulate the response of a winding which has unique design. It presents a new technique to calculate the resistance, inductance and capacitance of the winding. Then, the relationship between the RLC parameters and the frequency response is studied. The winding chosen in this investigation is a single phase 33kV transformer winding. The simulated frequency response was compared with the measured response to verify the proposed model. The model can give a comprehensive understanding about the effect of RLC parameters on the frequency response. Institute of Advanced Engineering and Science 2019 Article PeerReviewed Al-Ameri, S. and Yousof, M. F. M. and Azis, Norhafiz and Avinash S. and Talib, M. A. and Salem, Ali. A. (2019) Frequency response of transformer winding to investigate the influence of RLC. Indonesian Journal of Electrical Engineering and Computer Science, 14 (1). pp. 219-229. ISSN 2502-4752; ESSN: 2502-4760 https://ijeecs.iaescore.com/index.php/IJEECS/article/view/16791 10.11591/ijeecs.v14.i1.pp219-229
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
description Frequency response measurements are used for power transformer winding failures detection. The variation between frequency responses indicate mechanical changes in the transformer winding. One method to investigate winding failures in transformer is to develop a reliable circuit model which can simulate the frequency response of an actual winding. The main reason to use the model is because it is expensive to create damages on an actual winding. This paper proposes n-stages circuit ladder network to simulate the response of a winding which has unique design. It presents a new technique to calculate the resistance, inductance and capacitance of the winding. Then, the relationship between the RLC parameters and the frequency response is studied. The winding chosen in this investigation is a single phase 33kV transformer winding. The simulated frequency response was compared with the measured response to verify the proposed model. The model can give a comprehensive understanding about the effect of RLC parameters on the frequency response.
format Article
author Al-Ameri, S.
Yousof, M. F. M.
Azis, Norhafiz
Avinash S.
Talib, M. A.
Salem, Ali. A.
spellingShingle Al-Ameri, S.
Yousof, M. F. M.
Azis, Norhafiz
Avinash S.
Talib, M. A.
Salem, Ali. A.
Frequency response of transformer winding to investigate the influence of RLC
author_facet Al-Ameri, S.
Yousof, M. F. M.
Azis, Norhafiz
Avinash S.
Talib, M. A.
Salem, Ali. A.
author_sort Al-Ameri, S.
title Frequency response of transformer winding to investigate the influence of RLC
title_short Frequency response of transformer winding to investigate the influence of RLC
title_full Frequency response of transformer winding to investigate the influence of RLC
title_fullStr Frequency response of transformer winding to investigate the influence of RLC
title_full_unstemmed Frequency response of transformer winding to investigate the influence of RLC
title_sort frequency response of transformer winding to investigate the influence of rlc
publisher Institute of Advanced Engineering and Science
publishDate 2019
url http://psasir.upm.edu.my/id/eprint/79952/
https://ijeecs.iaescore.com/index.php/IJEECS/article/view/16791
_version_ 1762394201623887872
score 13.211869