Dosimetric response of fabricated Ge-doped optical fibres in computed tomography RQT beam quality x-ray beams

Novel germanium (Ge)-doped silica glass fibres tailor-made in Malaysia are fast gaining recognition as potential media for thermoluminescence (TL) dosimetry, with active research ongoing into exploitation of their various beneficial characteristics. Investigation is made herein of the capability of...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohd Rais, Nur Nadiah, Bradley, David A., Hashim, Asmaliza, Mohd Isa, Nur Ayuni, Osman, Noor Diyana, Itam @ Ismail, Iskasymar, Abu Hassan, Hasyma, Mohd Noor, Noramaliza
Format: Article
Language:English
Published: IOP Publishing 2019
Online Access:http://psasir.upm.edu.my/id/eprint/79445/1/Dosimetric%20response%20of%20fabricated%20.pdf
http://psasir.upm.edu.my/id/eprint/79445/
https://pubmed.ncbi.nlm.nih.gov/31018196/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.79445
record_format eprints
spelling my.upm.eprints.794452021-04-08T00:45:25Z http://psasir.upm.edu.my/id/eprint/79445/ Dosimetric response of fabricated Ge-doped optical fibres in computed tomography RQT beam quality x-ray beams Mohd Rais, Nur Nadiah Bradley, David A. Hashim, Asmaliza Mohd Isa, Nur Ayuni Osman, Noor Diyana Itam @ Ismail, Iskasymar Abu Hassan, Hasyma Mohd Noor, Noramaliza Novel germanium (Ge)-doped silica glass fibres tailor-made in Malaysia are fast gaining recognition as potential media for thermoluminescence (TL) dosimetry, with active research ongoing into exploitation of their various beneficial characteristics. Investigation is made herein of the capability of these media for use in diagnostic imaging dosimetry, specifically at the radiation dose levels typically obtained in conduct of Computed Tomography (CT). As a first step within such efforts, there is need to investigate the performance of the fibres using tightly defined spectra, use being made of a Philips constant potential industrial x-ray facility, Model MG165, located at the Malaysian Nuclear Agency Secondary Standards Dosimetry Lab (SSDL). Standard radiation beam qualities (termed RQT) have been established for CT, in accord with IEC 61267: 2003 and IAEA Technical Reports Series No. 457: 2007. A calibrated ionisation chamber has also been utilised, forming a component part of the SSDL equipment. The fabricated fibres used in this study are 2.3 mol% flat fibre (FF) of dimensions 643 × 356 μm2 and 2.3 mol% cylindrical fibre (CF) of 481 μm diameter, while the commercial fibre used is 4 mol% with core diameter of 50 μm. The dopant concentrations are nominal preform values. The fibres have been irradiated to doses of 20, 30 and 40 milligray (mGy) for each of the beam qualities RQT 8, RQT 9 and RQT 10. For x-rays generated at constant potential values from 100 to 150 kV, a discernible energy-dependent response is seen, comparisons being made with that of lithium fluoride (LiF) thermoluminescence dosimeters (TLD-100). TL yield versus dose has also been investigated for x-ray doses from 2 to 40 mGy, all exhibiting linearity. Compared to TLD-100, greater sensitivity is observed for the fibres. IOP Publishing 2019 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/79445/1/Dosimetric%20response%20of%20fabricated%20.pdf Mohd Rais, Nur Nadiah and Bradley, David A. and Hashim, Asmaliza and Mohd Isa, Nur Ayuni and Osman, Noor Diyana and Itam @ Ismail, Iskasymar and Abu Hassan, Hasyma and Mohd Noor, Noramaliza (2019) Dosimetric response of fabricated Ge-doped optical fibres in computed tomography RQT beam quality x-ray beams. Journal of Radiological Protection, 39 (3). pp. 8-18. ISSN 0952-4746; ESSN: 1361-6498 https://pubmed.ncbi.nlm.nih.gov/31018196/ 10.1088/1361-6498/ab1c16
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description Novel germanium (Ge)-doped silica glass fibres tailor-made in Malaysia are fast gaining recognition as potential media for thermoluminescence (TL) dosimetry, with active research ongoing into exploitation of their various beneficial characteristics. Investigation is made herein of the capability of these media for use in diagnostic imaging dosimetry, specifically at the radiation dose levels typically obtained in conduct of Computed Tomography (CT). As a first step within such efforts, there is need to investigate the performance of the fibres using tightly defined spectra, use being made of a Philips constant potential industrial x-ray facility, Model MG165, located at the Malaysian Nuclear Agency Secondary Standards Dosimetry Lab (SSDL). Standard radiation beam qualities (termed RQT) have been established for CT, in accord with IEC 61267: 2003 and IAEA Technical Reports Series No. 457: 2007. A calibrated ionisation chamber has also been utilised, forming a component part of the SSDL equipment. The fabricated fibres used in this study are 2.3 mol% flat fibre (FF) of dimensions 643 × 356 μm2 and 2.3 mol% cylindrical fibre (CF) of 481 μm diameter, while the commercial fibre used is 4 mol% with core diameter of 50 μm. The dopant concentrations are nominal preform values. The fibres have been irradiated to doses of 20, 30 and 40 milligray (mGy) for each of the beam qualities RQT 8, RQT 9 and RQT 10. For x-rays generated at constant potential values from 100 to 150 kV, a discernible energy-dependent response is seen, comparisons being made with that of lithium fluoride (LiF) thermoluminescence dosimeters (TLD-100). TL yield versus dose has also been investigated for x-ray doses from 2 to 40 mGy, all exhibiting linearity. Compared to TLD-100, greater sensitivity is observed for the fibres.
format Article
author Mohd Rais, Nur Nadiah
Bradley, David A.
Hashim, Asmaliza
Mohd Isa, Nur Ayuni
Osman, Noor Diyana
Itam @ Ismail, Iskasymar
Abu Hassan, Hasyma
Mohd Noor, Noramaliza
spellingShingle Mohd Rais, Nur Nadiah
Bradley, David A.
Hashim, Asmaliza
Mohd Isa, Nur Ayuni
Osman, Noor Diyana
Itam @ Ismail, Iskasymar
Abu Hassan, Hasyma
Mohd Noor, Noramaliza
Dosimetric response of fabricated Ge-doped optical fibres in computed tomography RQT beam quality x-ray beams
author_facet Mohd Rais, Nur Nadiah
Bradley, David A.
Hashim, Asmaliza
Mohd Isa, Nur Ayuni
Osman, Noor Diyana
Itam @ Ismail, Iskasymar
Abu Hassan, Hasyma
Mohd Noor, Noramaliza
author_sort Mohd Rais, Nur Nadiah
title Dosimetric response of fabricated Ge-doped optical fibres in computed tomography RQT beam quality x-ray beams
title_short Dosimetric response of fabricated Ge-doped optical fibres in computed tomography RQT beam quality x-ray beams
title_full Dosimetric response of fabricated Ge-doped optical fibres in computed tomography RQT beam quality x-ray beams
title_fullStr Dosimetric response of fabricated Ge-doped optical fibres in computed tomography RQT beam quality x-ray beams
title_full_unstemmed Dosimetric response of fabricated Ge-doped optical fibres in computed tomography RQT beam quality x-ray beams
title_sort dosimetric response of fabricated ge-doped optical fibres in computed tomography rqt beam quality x-ray beams
publisher IOP Publishing
publishDate 2019
url http://psasir.upm.edu.my/id/eprint/79445/1/Dosimetric%20response%20of%20fabricated%20.pdf
http://psasir.upm.edu.my/id/eprint/79445/
https://pubmed.ncbi.nlm.nih.gov/31018196/
_version_ 1696977673806413824
score 13.160551