Response modification factors for reinforced concrete structures equipped with viscous damper devices

The response modification factor is one of the seismic design parameters that determine the nonlinear performance of building structures during strong earthquakes. Most seismic design codes lead to reduced loads. Nevertheless, an extensive review of related literature indicates that the effect of vi...

Full description

Saved in:
Bibliographic Details
Main Authors: Abdi, Heshmatollah, Hejazi, Farzad, Jaafar, Mohd Saleh, Abd Karim, Izian
Format: Article
Language:English
Published: Budapest University of Technology and Economics 2018
Online Access:http://psasir.upm.edu.my/id/eprint/73777/1/Response%20modification%20factors%20for%20reinforced%20concrete%20structures%20equipped%20with%20viscous%20damper%20devices.pdf
http://psasir.upm.edu.my/id/eprint/73777/
https://pp.bme.hu/ci/article/view/8311
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.73777
record_format eprints
spelling my.upm.eprints.737772020-05-08T16:01:45Z http://psasir.upm.edu.my/id/eprint/73777/ Response modification factors for reinforced concrete structures equipped with viscous damper devices Abdi, Heshmatollah Hejazi, Farzad Jaafar, Mohd Saleh Abd Karim, Izian The response modification factor is one of the seismic design parameters that determine the nonlinear performance of building structures during strong earthquakes. Most seismic design codes lead to reduced loads. Nevertheless, an extensive review of related literature indicates that the effect of viscous dampers on the response modification factor is no longer considered. In this study, the effect of implementing viscous damper devices in reinforced concrete structures on the response modification factor was investigated. Reinforced concrete structures with different stories were considered to evaluate the values of the response modification factors. A nonlinear statistic analysis was performed with finite element software. The values of the response modification factors were evaluated and formulated on the basis of three factors: strength, ductility, and redundancy. Results revealed that the response modification factors for reinforced concrete structures equipped with viscous damper devices are higher than those for structures without viscous damper devices. The number of damper devices and the height of buildings have significant effects on response modification factors. In view of the analytical results across different cases, we proposed an equation according to the values of damping coefficients to determine the response modification factors for reinforced concrete structures furnished with viscous damper devices. Budapest University of Technology and Economics 2018 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/73777/1/Response%20modification%20factors%20for%20reinforced%20concrete%20structures%20equipped%20with%20viscous%20damper%20devices.pdf Abdi, Heshmatollah and Hejazi, Farzad and Jaafar, Mohd Saleh and Abd Karim, Izian (2018) Response modification factors for reinforced concrete structures equipped with viscous damper devices. Periodica Polytechnica-Civil Engineering, 62 (1). pp. 11-25. ISSN ESSN: 1587-3773 https://pp.bme.hu/ci/article/view/8311 10.3311/PPci.8311
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description The response modification factor is one of the seismic design parameters that determine the nonlinear performance of building structures during strong earthquakes. Most seismic design codes lead to reduced loads. Nevertheless, an extensive review of related literature indicates that the effect of viscous dampers on the response modification factor is no longer considered. In this study, the effect of implementing viscous damper devices in reinforced concrete structures on the response modification factor was investigated. Reinforced concrete structures with different stories were considered to evaluate the values of the response modification factors. A nonlinear statistic analysis was performed with finite element software. The values of the response modification factors were evaluated and formulated on the basis of three factors: strength, ductility, and redundancy. Results revealed that the response modification factors for reinforced concrete structures equipped with viscous damper devices are higher than those for structures without viscous damper devices. The number of damper devices and the height of buildings have significant effects on response modification factors. In view of the analytical results across different cases, we proposed an equation according to the values of damping coefficients to determine the response modification factors for reinforced concrete structures furnished with viscous damper devices.
format Article
author Abdi, Heshmatollah
Hejazi, Farzad
Jaafar, Mohd Saleh
Abd Karim, Izian
spellingShingle Abdi, Heshmatollah
Hejazi, Farzad
Jaafar, Mohd Saleh
Abd Karim, Izian
Response modification factors for reinforced concrete structures equipped with viscous damper devices
author_facet Abdi, Heshmatollah
Hejazi, Farzad
Jaafar, Mohd Saleh
Abd Karim, Izian
author_sort Abdi, Heshmatollah
title Response modification factors for reinforced concrete structures equipped with viscous damper devices
title_short Response modification factors for reinforced concrete structures equipped with viscous damper devices
title_full Response modification factors for reinforced concrete structures equipped with viscous damper devices
title_fullStr Response modification factors for reinforced concrete structures equipped with viscous damper devices
title_full_unstemmed Response modification factors for reinforced concrete structures equipped with viscous damper devices
title_sort response modification factors for reinforced concrete structures equipped with viscous damper devices
publisher Budapest University of Technology and Economics
publishDate 2018
url http://psasir.upm.edu.my/id/eprint/73777/1/Response%20modification%20factors%20for%20reinforced%20concrete%20structures%20equipped%20with%20viscous%20damper%20devices.pdf
http://psasir.upm.edu.my/id/eprint/73777/
https://pp.bme.hu/ci/article/view/8311
_version_ 1669008831384911872
score 13.160551