Fourier analysis of motor current for diagnosis of broken bars in squirrel-cage induction machines

Condition monitoring, signal processing and data analysis are the key parts of the induction machine (IM) fault detection scheme. Frequency analysis of the signal acquired through the condition monitoring is commonly applied for motor fault detection. This paper is intended to investigate the abilit...

Full description

Saved in:
Bibliographic Details
Main Authors: Mehrjou, Mohammad Rezazadeh, Mariun, Norman, Marhaban, Mohammad Hamiruce, Misron, Norhisam
Format: Conference or Workshop Item
Language:English
Published: IEEE 2010
Online Access:http://psasir.upm.edu.my/id/eprint/68759/1/Fourier%20analysis%20of%20motor%20current%20for%20diagnosis%20of%20broken%20bars%20in%20squirrel-cage%20induction%20machines.pdf
http://psasir.upm.edu.my/id/eprint/68759/