Performance of various connection system for IBS structure subjected to cyclic load

Nowadays, application of precast constructions is increasing, due to benefit of the industrialized building systems, specially the performance of this type of construction structures when effects of dynamic loads are considered. Precast beam column connection is mostly the critical part in the struc...

Full description

Saved in:
Bibliographic Details
Main Authors: Sadeq, Iman, Hejazi, Farzad, Jabbar, Sarah
Format: Conference or Workshop Item
Language:English
Published: Springer Nature Singapore 2017
Online Access:http://psasir.upm.edu.my/id/eprint/64614/1/Performance%20of%20various%20connection%20system%20for%20IBS%20structure%20subjected%20to%20cyclic%20load.pdf
http://psasir.upm.edu.my/id/eprint/64614/
https://link.springer.com/chapter/10.1007/978-981-10-8016-6_43
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.64614
record_format eprints
spelling my.upm.eprints.646142018-08-13T03:10:21Z http://psasir.upm.edu.my/id/eprint/64614/ Performance of various connection system for IBS structure subjected to cyclic load Sadeq, Iman Hejazi, Farzad Jabbar, Sarah Nowadays, application of precast constructions is increasing, due to benefit of the industrialized building systems, specially the performance of this type of construction structures when effects of dynamic loads are considered. Precast beam column connection is mostly the critical part in the structures to resist the loads, so that the attention must be paid while designing such connections. Therefore, the aim of this study is to evaluate the efficiency of the precast concrete beam–column connection comparing with the conventional joints. Three-dimensional nonlinear analysis was conducted using finite element method with five beam–column connections under the effect of cyclic load, bearing pad, steel dowel, and steel angle cleat were used to improve the connections performance. The results indicated that the using of steel angle cleat and dowel together and doubling angle cleat have improved the lateral resistance of the precast connections as well as the lateral stiffness and the ability to dissipate damage energy when comparing with the conventional joint performance. Springer Nature Singapore 2017 Conference or Workshop Item PeerReviewed text en http://psasir.upm.edu.my/id/eprint/64614/1/Performance%20of%20various%20connection%20system%20for%20IBS%20structure%20subjected%20to%20cyclic%20load.pdf Sadeq, Iman and Hejazi, Farzad and Jabbar, Sarah (2017) Performance of various connection system for IBS structure subjected to cyclic load. In: Global Civil Engineering Conference (GCEC 2017), 25-28 July 2017, Kuala Lumpur, Malaysia. (pp. 543-559). https://link.springer.com/chapter/10.1007/978-981-10-8016-6_43 10.1007/978-981-10-8016-6_43
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description Nowadays, application of precast constructions is increasing, due to benefit of the industrialized building systems, specially the performance of this type of construction structures when effects of dynamic loads are considered. Precast beam column connection is mostly the critical part in the structures to resist the loads, so that the attention must be paid while designing such connections. Therefore, the aim of this study is to evaluate the efficiency of the precast concrete beam–column connection comparing with the conventional joints. Three-dimensional nonlinear analysis was conducted using finite element method with five beam–column connections under the effect of cyclic load, bearing pad, steel dowel, and steel angle cleat were used to improve the connections performance. The results indicated that the using of steel angle cleat and dowel together and doubling angle cleat have improved the lateral resistance of the precast connections as well as the lateral stiffness and the ability to dissipate damage energy when comparing with the conventional joint performance.
format Conference or Workshop Item
author Sadeq, Iman
Hejazi, Farzad
Jabbar, Sarah
spellingShingle Sadeq, Iman
Hejazi, Farzad
Jabbar, Sarah
Performance of various connection system for IBS structure subjected to cyclic load
author_facet Sadeq, Iman
Hejazi, Farzad
Jabbar, Sarah
author_sort Sadeq, Iman
title Performance of various connection system for IBS structure subjected to cyclic load
title_short Performance of various connection system for IBS structure subjected to cyclic load
title_full Performance of various connection system for IBS structure subjected to cyclic load
title_fullStr Performance of various connection system for IBS structure subjected to cyclic load
title_full_unstemmed Performance of various connection system for IBS structure subjected to cyclic load
title_sort performance of various connection system for ibs structure subjected to cyclic load
publisher Springer Nature Singapore
publishDate 2017
url http://psasir.upm.edu.my/id/eprint/64614/1/Performance%20of%20various%20connection%20system%20for%20IBS%20structure%20subjected%20to%20cyclic%20load.pdf
http://psasir.upm.edu.my/id/eprint/64614/
https://link.springer.com/chapter/10.1007/978-981-10-8016-6_43
_version_ 1643838074024624128
score 13.18916