Significant insights into the operation of DC-link voltage control of a shunt active power filter using different control algorithms: a comparative study

A comparative study between a conventional DC-link voltage control algorithm (CDVCA) and a self-charging DC-link voltage control algorithm (SDVCA) is presented. It focuses on the principle operation of both algorithms and their impacts on the performance of a shunt active power filter (SAPF) operati...

Full description

Saved in:
Bibliographic Details
Main Authors: Abdul Rahman, Nor Farahaida, Mohd Radzi, Mohd Amran, Che Soh, Azura, Mariun, Norman, Abd Rahim, Nasrudin
Format: Article
Language:English
Published: Scientific and Technological Research Council of Turkey 2017
Online Access:http://psasir.upm.edu.my/id/eprint/63213/1/Significant%20insights%20into%20the%20operation%20of%20DC-link%20voltage%20control%20of%20a%20shunt%20active%20power%20.pdf
http://psasir.upm.edu.my/id/eprint/63213/
http://journals.tubitak.gov.tr/elektrik/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.63213
record_format eprints
spelling my.upm.eprints.632132018-08-20T06:24:11Z http://psasir.upm.edu.my/id/eprint/63213/ Significant insights into the operation of DC-link voltage control of a shunt active power filter using different control algorithms: a comparative study Abdul Rahman, Nor Farahaida Mohd Radzi, Mohd Amran Che Soh, Azura Mariun, Norman Abd Rahim, Nasrudin A comparative study between a conventional DC-link voltage control algorithm (CDVCA) and a self-charging DC-link voltage control algorithm (SDVCA) is presented. It focuses on the principle operation of both algorithms and their impacts on the performance of a shunt active power filter (SAPF) operation. All analyses are based on the step response of DC-link voltages under different start-up times of the SAPF and different initial DC-link voltage values. Other considered parameters are the ripple factor (RP) of DC-link voltages, estimated and measured DC-link charging currents, and total harmonic distortion (THD) value of supply currents. Thus, this study provides new insights into the operation of DC-link voltage control using different control algorithms. According to the simulation results, the SAPF using the SDVCA has shown better performance than using the CDVCA. By using the SDVCA, the charging process of a DC-link capacitor starts almost instantaneously. Additionally, the overshoot, settling time, and RF of DC-link voltages are reduced. Other than that, THD values of supply currents are improved, by generating low ripple of estimated DC-link charging currents. Experimental validation of the SAPF using the SDVCA is also presented. Scientific and Technological Research Council of Turkey 2017 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/63213/1/Significant%20insights%20into%20the%20operation%20of%20DC-link%20voltage%20control%20of%20a%20shunt%20active%20power%20.pdf Abdul Rahman, Nor Farahaida and Mohd Radzi, Mohd Amran and Che Soh, Azura and Mariun, Norman and Abd Rahim, Nasrudin (2017) Significant insights into the operation of DC-link voltage control of a shunt active power filter using different control algorithms: a comparative study. Turkish Journal of Electrical Engineering & Computer Sciences, 25 (3). pp. 2033-2043. ISSN 1300-0632; ESSN: 1303-6203 http://journals.tubitak.gov.tr/elektrik/ 10.3906/elk-1504-17
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description A comparative study between a conventional DC-link voltage control algorithm (CDVCA) and a self-charging DC-link voltage control algorithm (SDVCA) is presented. It focuses on the principle operation of both algorithms and their impacts on the performance of a shunt active power filter (SAPF) operation. All analyses are based on the step response of DC-link voltages under different start-up times of the SAPF and different initial DC-link voltage values. Other considered parameters are the ripple factor (RP) of DC-link voltages, estimated and measured DC-link charging currents, and total harmonic distortion (THD) value of supply currents. Thus, this study provides new insights into the operation of DC-link voltage control using different control algorithms. According to the simulation results, the SAPF using the SDVCA has shown better performance than using the CDVCA. By using the SDVCA, the charging process of a DC-link capacitor starts almost instantaneously. Additionally, the overshoot, settling time, and RF of DC-link voltages are reduced. Other than that, THD values of supply currents are improved, by generating low ripple of estimated DC-link charging currents. Experimental validation of the SAPF using the SDVCA is also presented.
format Article
author Abdul Rahman, Nor Farahaida
Mohd Radzi, Mohd Amran
Che Soh, Azura
Mariun, Norman
Abd Rahim, Nasrudin
spellingShingle Abdul Rahman, Nor Farahaida
Mohd Radzi, Mohd Amran
Che Soh, Azura
Mariun, Norman
Abd Rahim, Nasrudin
Significant insights into the operation of DC-link voltage control of a shunt active power filter using different control algorithms: a comparative study
author_facet Abdul Rahman, Nor Farahaida
Mohd Radzi, Mohd Amran
Che Soh, Azura
Mariun, Norman
Abd Rahim, Nasrudin
author_sort Abdul Rahman, Nor Farahaida
title Significant insights into the operation of DC-link voltage control of a shunt active power filter using different control algorithms: a comparative study
title_short Significant insights into the operation of DC-link voltage control of a shunt active power filter using different control algorithms: a comparative study
title_full Significant insights into the operation of DC-link voltage control of a shunt active power filter using different control algorithms: a comparative study
title_fullStr Significant insights into the operation of DC-link voltage control of a shunt active power filter using different control algorithms: a comparative study
title_full_unstemmed Significant insights into the operation of DC-link voltage control of a shunt active power filter using different control algorithms: a comparative study
title_sort significant insights into the operation of dc-link voltage control of a shunt active power filter using different control algorithms: a comparative study
publisher Scientific and Technological Research Council of Turkey
publishDate 2017
url http://psasir.upm.edu.my/id/eprint/63213/1/Significant%20insights%20into%20the%20operation%20of%20DC-link%20voltage%20control%20of%20a%20shunt%20active%20power%20.pdf
http://psasir.upm.edu.my/id/eprint/63213/
http://journals.tubitak.gov.tr/elektrik/
_version_ 1643837747814727680
score 13.211869