Fabrication of Polypyrrole-Mcm41 Nanocomposites Using Electrodeposition Method
Purely siliceous MCM-4 1 (SiMCM-4 1) and aluminium-containing MCM-4 1 (AIMCM-41) with different ratios of AVSi were synthesized following a modified procedure of Ryoo and Kim (1 995). PolypyrroleJMCM-4 1 (PPyJMCM-4 1) conductive polymer nanocomposite films was electrochemically prepared on Indium...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English English |
Published: |
2006
|
Subjects: | |
Online Access: | http://psasir.upm.edu.my/id/eprint/6297/1/FS_2006_33.pdf http://psasir.upm.edu.my/id/eprint/6297/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.upm.eprints.6297 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.62972023-10-20T08:54:24Z http://psasir.upm.edu.my/id/eprint/6297/ Fabrication of Polypyrrole-Mcm41 Nanocomposites Using Electrodeposition Method Yahaya, Rozita Purely siliceous MCM-4 1 (SiMCM-4 1) and aluminium-containing MCM-4 1 (AIMCM-41) with different ratios of AVSi were synthesized following a modified procedure of Ryoo and Kim (1 995). PolypyrroleJMCM-4 1 (PPyJMCM-4 1) conductive polymer nanocomposite films was electrochemically prepared on Indium Tin Oxide (ITO) glass electrode from an aqueous solution of pyrrole monomer and ptoluene sulfonate dopant in a suspension of prepared MCM-41. Various PPy/MCM- 41 nanocomposite films were obtained by varying the experimental conditions with the objective of producing conductive polymer nanocomposites with enhanced thermal and conductivity properties. The prepared nanocomposite films were characterized by Fourier Transform Infrared (FTIR) Spectroscopy, X-ray diffraction (XRD) analysis, Thermogravimetric Analysis, Scanning Electron Microscopy (SEM), Transmission Electron Microscopy (TEM) and conductivity measurements. From observations of the XRD patterns, nanocomposites prepared at low AVSi ratio (PPyJA130 and PPyJA140) and PPyJSiMCM-41 showed better crystallinity compared to those prepared at high AlJSi ratio (PPyJA160 and PPyJA180) which was observed to be amorphous. FTIR and XRD studies showed that the PPy and SiMCM-41 are the most compatible for the formation of PPyJSiMCM-41 nanocomposite. The TGA analysis and conductivity studies showed that the best nanocomposite was PPyJSiMCM-41 which was found to be the most thermally stable with the highest conductivity of 5.24 SJcm. This sample was obtained with optimum condition with 0.5 M pyrrole, 0.1 M p-toluene sulfonate and 3 g/dm3 MCM-41 at 1.2 volt (vs SCE). 2006-04 Thesis NonPeerReviewed text en http://psasir.upm.edu.my/id/eprint/6297/1/FS_2006_33.pdf Yahaya, Rozita (2006) Fabrication of Polypyrrole-Mcm41 Nanocomposites Using Electrodeposition Method. Masters thesis, Universiti Putra Malaysia. Nanocomposites (Materials) Alloy plating English |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English English |
topic |
Nanocomposites (Materials) Alloy plating |
spellingShingle |
Nanocomposites (Materials) Alloy plating Yahaya, Rozita Fabrication of Polypyrrole-Mcm41 Nanocomposites Using Electrodeposition Method |
description |
Purely siliceous MCM-4 1 (SiMCM-4 1) and aluminium-containing MCM-4 1
(AIMCM-41) with different ratios of AVSi were synthesized following a modified
procedure of Ryoo and Kim (1 995). PolypyrroleJMCM-4 1 (PPyJMCM-4 1)
conductive polymer nanocomposite films was electrochemically prepared on Indium
Tin Oxide (ITO) glass electrode from an aqueous solution of pyrrole monomer and ptoluene
sulfonate dopant in a suspension of prepared MCM-41. Various PPy/MCM-
41 nanocomposite films were obtained by varying the experimental conditions with
the objective of producing conductive polymer nanocomposites with enhanced
thermal and conductivity properties. The prepared nanocomposite films were
characterized by Fourier Transform Infrared (FTIR) Spectroscopy, X-ray diffraction
(XRD) analysis, Thermogravimetric Analysis, Scanning Electron Microscopy (SEM),
Transmission Electron Microscopy (TEM) and conductivity measurements. From observations of the XRD patterns, nanocomposites prepared at low AVSi ratio
(PPyJA130 and PPyJA140) and PPyJSiMCM-41 showed better crystallinity compared
to those prepared at high AlJSi ratio (PPyJA160 and PPyJA180) which was observed to
be amorphous. FTIR and XRD studies showed that the PPy and SiMCM-41 are the
most compatible for the formation of PPyJSiMCM-41 nanocomposite. The TGA
analysis and conductivity studies showed that the best nanocomposite was
PPyJSiMCM-41 which was found to be the most thermally stable with the highest
conductivity of 5.24 SJcm. This sample was obtained with optimum condition with
0.5 M pyrrole, 0.1 M p-toluene sulfonate and 3 g/dm3 MCM-41 at 1.2 volt (vs SCE). |
format |
Thesis |
author |
Yahaya, Rozita |
author_facet |
Yahaya, Rozita |
author_sort |
Yahaya, Rozita |
title |
Fabrication of Polypyrrole-Mcm41 Nanocomposites Using Electrodeposition Method |
title_short |
Fabrication of Polypyrrole-Mcm41 Nanocomposites Using Electrodeposition Method |
title_full |
Fabrication of Polypyrrole-Mcm41 Nanocomposites Using Electrodeposition Method |
title_fullStr |
Fabrication of Polypyrrole-Mcm41 Nanocomposites Using Electrodeposition Method |
title_full_unstemmed |
Fabrication of Polypyrrole-Mcm41 Nanocomposites Using Electrodeposition Method |
title_sort |
fabrication of polypyrrole-mcm41 nanocomposites using electrodeposition method |
publishDate |
2006 |
url |
http://psasir.upm.edu.my/id/eprint/6297/1/FS_2006_33.pdf http://psasir.upm.edu.my/id/eprint/6297/ |
_version_ |
1781706623342870528 |
score |