Detection of fastener loosening in simple lap joint based on ultrasonic wavefield imaging

Joints in aero-mechanical structures are critical elements that ensure the structural integrity but they are prone to damages. Inspection of such joints that have no prior baseline data is really challenging but it can be possibly done using the Ultrasonic Propagation Imager (UPI). The feasibility o...

Full description

Saved in:
Bibliographic Details
Main Authors: Gooda Sahib, Muhammad Isfaaq, Leong, Shii Jang, Chia, Chen Ciang, Mustapha, Faizal
Format: Conference or Workshop Item
Language:English
Published: IOP Publishing 2017
Online Access:http://psasir.upm.edu.my/id/eprint/61409/1/Detection%20of%20fastener%20loosening%20in%20simple%20lap%20joint%20.pdf
http://psasir.upm.edu.my/id/eprint/61409/
http://iopscience.iop.org/article/10.1088/1757-899X/270/1/012035
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.61409
record_format eprints
spelling my.upm.eprints.614092018-10-09T06:23:00Z http://psasir.upm.edu.my/id/eprint/61409/ Detection of fastener loosening in simple lap joint based on ultrasonic wavefield imaging Gooda Sahib, Muhammad Isfaaq Leong, Shii Jang Chia, Chen Ciang Mustapha, Faizal Joints in aero-mechanical structures are critical elements that ensure the structural integrity but they are prone to damages. Inspection of such joints that have no prior baseline data is really challenging but it can be possibly done using the Ultrasonic Propagation Imager (UPI). The feasibility of applying UPI for detection of loosened fastener is investigated in this study. A simple lap joint specimen made by connecting two pieces of 2.5mm thick SAE304 stainless steel plates using five M6 screws and nuts has been used in this study. All fasteners are tightened to 10Nm but one of them is completely loosened to simulate the damage. The wavefield data is processed into ultrasonic wavefield propagation video and a series of spectral amplitude images. The spectral images showed noticeable amplitude difference at the loosened fastener, hence confirmed the feasibility of using UPI for structural joints inspection. A simple contrast maximization method is also introduced to improve the result. IOP Publishing 2017 Conference or Workshop Item PeerReviewed text en http://psasir.upm.edu.my/id/eprint/61409/1/Detection%20of%20fastener%20loosening%20in%20simple%20lap%20joint%20.pdf Gooda Sahib, Muhammad Isfaaq and Leong, Shii Jang and Chia, Chen Ciang and Mustapha, Faizal (2017) Detection of fastener loosening in simple lap joint based on ultrasonic wavefield imaging. In: AEROS Conference 2017, 12 Dec. 2017, Shangri-La Hotel, Putrajaya, Malaysia. (pp. 1-7). http://iopscience.iop.org/article/10.1088/1757-899X/270/1/012035 10.1088/1757-899X/270/1/012035
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description Joints in aero-mechanical structures are critical elements that ensure the structural integrity but they are prone to damages. Inspection of such joints that have no prior baseline data is really challenging but it can be possibly done using the Ultrasonic Propagation Imager (UPI). The feasibility of applying UPI for detection of loosened fastener is investigated in this study. A simple lap joint specimen made by connecting two pieces of 2.5mm thick SAE304 stainless steel plates using five M6 screws and nuts has been used in this study. All fasteners are tightened to 10Nm but one of them is completely loosened to simulate the damage. The wavefield data is processed into ultrasonic wavefield propagation video and a series of spectral amplitude images. The spectral images showed noticeable amplitude difference at the loosened fastener, hence confirmed the feasibility of using UPI for structural joints inspection. A simple contrast maximization method is also introduced to improve the result.
format Conference or Workshop Item
author Gooda Sahib, Muhammad Isfaaq
Leong, Shii Jang
Chia, Chen Ciang
Mustapha, Faizal
spellingShingle Gooda Sahib, Muhammad Isfaaq
Leong, Shii Jang
Chia, Chen Ciang
Mustapha, Faizal
Detection of fastener loosening in simple lap joint based on ultrasonic wavefield imaging
author_facet Gooda Sahib, Muhammad Isfaaq
Leong, Shii Jang
Chia, Chen Ciang
Mustapha, Faizal
author_sort Gooda Sahib, Muhammad Isfaaq
title Detection of fastener loosening in simple lap joint based on ultrasonic wavefield imaging
title_short Detection of fastener loosening in simple lap joint based on ultrasonic wavefield imaging
title_full Detection of fastener loosening in simple lap joint based on ultrasonic wavefield imaging
title_fullStr Detection of fastener loosening in simple lap joint based on ultrasonic wavefield imaging
title_full_unstemmed Detection of fastener loosening in simple lap joint based on ultrasonic wavefield imaging
title_sort detection of fastener loosening in simple lap joint based on ultrasonic wavefield imaging
publisher IOP Publishing
publishDate 2017
url http://psasir.upm.edu.my/id/eprint/61409/1/Detection%20of%20fastener%20loosening%20in%20simple%20lap%20joint%20.pdf
http://psasir.upm.edu.my/id/eprint/61409/
http://iopscience.iop.org/article/10.1088/1757-899X/270/1/012035
_version_ 1643837544682487808
score 13.188404