Performance evaluation of Modified Widrow-Hoff ADALINE under effect of photovoltaic with shunt active power filter

This paper investigates performances of Modified Widrow-Hoff ADALINE as harmonics extraction algorithm under effect of photovoltaic (PV) integrated with shunt active power filter (SAPF). Integration of PV with SAPF gives high advantages in terms of energy source and power quality. The dependable on...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohd Zainuri, Muhammad Ammirrul Atiqi, Mohd Radzi, Mohd Amran, Che Soh, Azura, Mariun, Norman, Abd Rahim, Nasrudin
Format: Conference or Workshop Item
Language:English
Published: IEEE 2016
Online Access:http://psasir.upm.edu.my/id/eprint/59423/1/Performance%20evaluation%20of%20Modified%20Widrow-Hoff%20ADALINE%20under%20effect%20of%20photovoltaic%20with%20shunt%20active%20power%20filter.pdf
http://psasir.upm.edu.my/id/eprint/59423/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.59423
record_format eprints
spelling my.upm.eprints.594232018-03-02T04:13:20Z http://psasir.upm.edu.my/id/eprint/59423/ Performance evaluation of Modified Widrow-Hoff ADALINE under effect of photovoltaic with shunt active power filter Mohd Zainuri, Muhammad Ammirrul Atiqi Mohd Radzi, Mohd Amran Che Soh, Azura Mariun, Norman Abd Rahim, Nasrudin This paper investigates performances of Modified Widrow-Hoff ADALINE as harmonics extraction algorithm under effect of photovoltaic (PV) integrated with shunt active power filter (SAPF). Integration of PV with SAPF gives high advantages in terms of energy source and power quality. The dependable on grid supply current reduces as PV current may support good amount of current to the load. However, with off-on operation and various irradiance levels of the PV, a good harmonics extraction algorithm is needed. Meanwhile, Modified Widrow-Hoff ADALINE is already proven before in SAPF functionality, however, its performance should further be evaluated under integration of PV with SAPF. Therefore, this algorithm is proposed, and further designed and developed for PV based SAPF, as simulated in MATLAB/Simulink. From the simulation results, the Modified Widrow-Hoff algorithm shows good performances for PV based SAPF with low THD values, fast response times and reduced source power from the grid under various levels of irradiance. IEEE 2016 Conference or Workshop Item PeerReviewed text en http://psasir.upm.edu.my/id/eprint/59423/1/Performance%20evaluation%20of%20Modified%20Widrow-Hoff%20ADALINE%20under%20effect%20of%20photovoltaic%20with%20shunt%20active%20power%20filter.pdf Mohd Zainuri, Muhammad Ammirrul Atiqi and Mohd Radzi, Mohd Amran and Che Soh, Azura and Mariun, Norman and Abd Rahim, Nasrudin (2016) Performance evaluation of Modified Widrow-Hoff ADALINE under effect of photovoltaic with shunt active power filter. In: 2016 IEEE Industrial Electronics and Applications Conference (IEACon 2016), 20-22 Nov. 2016, Kota Kinabalu, Sabah. (pp. 128-132). 10.1109/IEACON.2016.8067368
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description This paper investigates performances of Modified Widrow-Hoff ADALINE as harmonics extraction algorithm under effect of photovoltaic (PV) integrated with shunt active power filter (SAPF). Integration of PV with SAPF gives high advantages in terms of energy source and power quality. The dependable on grid supply current reduces as PV current may support good amount of current to the load. However, with off-on operation and various irradiance levels of the PV, a good harmonics extraction algorithm is needed. Meanwhile, Modified Widrow-Hoff ADALINE is already proven before in SAPF functionality, however, its performance should further be evaluated under integration of PV with SAPF. Therefore, this algorithm is proposed, and further designed and developed for PV based SAPF, as simulated in MATLAB/Simulink. From the simulation results, the Modified Widrow-Hoff algorithm shows good performances for PV based SAPF with low THD values, fast response times and reduced source power from the grid under various levels of irradiance.
format Conference or Workshop Item
author Mohd Zainuri, Muhammad Ammirrul Atiqi
Mohd Radzi, Mohd Amran
Che Soh, Azura
Mariun, Norman
Abd Rahim, Nasrudin
spellingShingle Mohd Zainuri, Muhammad Ammirrul Atiqi
Mohd Radzi, Mohd Amran
Che Soh, Azura
Mariun, Norman
Abd Rahim, Nasrudin
Performance evaluation of Modified Widrow-Hoff ADALINE under effect of photovoltaic with shunt active power filter
author_facet Mohd Zainuri, Muhammad Ammirrul Atiqi
Mohd Radzi, Mohd Amran
Che Soh, Azura
Mariun, Norman
Abd Rahim, Nasrudin
author_sort Mohd Zainuri, Muhammad Ammirrul Atiqi
title Performance evaluation of Modified Widrow-Hoff ADALINE under effect of photovoltaic with shunt active power filter
title_short Performance evaluation of Modified Widrow-Hoff ADALINE under effect of photovoltaic with shunt active power filter
title_full Performance evaluation of Modified Widrow-Hoff ADALINE under effect of photovoltaic with shunt active power filter
title_fullStr Performance evaluation of Modified Widrow-Hoff ADALINE under effect of photovoltaic with shunt active power filter
title_full_unstemmed Performance evaluation of Modified Widrow-Hoff ADALINE under effect of photovoltaic with shunt active power filter
title_sort performance evaluation of modified widrow-hoff adaline under effect of photovoltaic with shunt active power filter
publisher IEEE
publishDate 2016
url http://psasir.upm.edu.my/id/eprint/59423/1/Performance%20evaluation%20of%20Modified%20Widrow-Hoff%20ADALINE%20under%20effect%20of%20photovoltaic%20with%20shunt%20active%20power%20filter.pdf
http://psasir.upm.edu.my/id/eprint/59423/
_version_ 1643837068017664000
score 13.211869