Development of a flow-through optosensor for determination of Co(II)
A flow-through optical fibre chemical sensor for the determination of Co(II) at trace level using immobilised 2-(4-pyridylazo)resorcinol (PAR) as the reagent phase is proposed. PAR is physically adsorbed onto XAD-7. This method provided a great sensitivity and simplicity with wide linear response ra...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English English |
Published: |
Elsevier
2008
|
Online Access: | http://psasir.upm.edu.my/id/eprint/5826/1/Development%20of%20a%20flow-through%20optosensor%20for%20determination%20of%20Co%28II%29.pdf http://psasir.upm.edu.my/id/eprint/5826/ http://dx.doi.org/10.1016/j.saa.2007.04.015 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.upm.eprints.5826 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.58262015-11-11T01:13:42Z http://psasir.upm.edu.my/id/eprint/5826/ Development of a flow-through optosensor for determination of Co(II) Yusof, Nor Azah Ahmad, Musa A flow-through optical fibre chemical sensor for the determination of Co(II) at trace level using immobilised 2-(4-pyridylazo)resorcinol (PAR) as the reagent phase is proposed. PAR is physically adsorbed onto XAD-7. This method provided a great sensitivity and simplicity with wide linear response range from 1 × 10−2 to 1 × 103 ppm and detection limit of 20 ppb. This method also showed a reproducible result with relative standard deviation (R.S.D.) of 1.78% and response time of 5 min. The response towards Co(II) was also reversible using acidified KCl as the regenerating solution. Interference studies showed that Cr(III) significantly interfered during the determination. Excellent agreement with reference to inductively coupled plasma optical emission spectroscopy (ICPOES) method was achieved when the developed sensor was applied for determination of Co(II) in aqueous samples. Elsevier 2008 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/5826/1/Development%20of%20a%20flow-through%20optosensor%20for%20determination%20of%20Co%28II%29.pdf Yusof, Nor Azah and Ahmad, Musa (2008) Development of a flow-through optosensor for determination of Co(II). Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 69 (2). pp. 413-418. ISSN 0584-8539 http://dx.doi.org/10.1016/j.saa.2007.04.015 10.1016/j.saa.2007.04.015 English |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English English |
description |
A flow-through optical fibre chemical sensor for the determination of Co(II) at trace level using immobilised 2-(4-pyridylazo)resorcinol (PAR) as the reagent phase is proposed. PAR is physically adsorbed onto XAD-7. This method provided a great sensitivity and simplicity with wide linear response range from 1 × 10−2 to 1 × 103 ppm and detection limit of 20 ppb. This method also showed a reproducible result with relative standard deviation (R.S.D.) of 1.78% and response time of 5 min. The response towards Co(II) was also reversible using acidified KCl as the regenerating solution. Interference studies showed that Cr(III) significantly interfered during the determination. Excellent agreement with reference to inductively coupled plasma optical emission spectroscopy (ICPOES) method was achieved when the developed sensor was applied for determination of Co(II) in aqueous samples.
|
format |
Article |
author |
Yusof, Nor Azah Ahmad, Musa |
spellingShingle |
Yusof, Nor Azah Ahmad, Musa Development of a flow-through optosensor for determination of Co(II) |
author_facet |
Yusof, Nor Azah Ahmad, Musa |
author_sort |
Yusof, Nor Azah |
title |
Development of a flow-through optosensor for determination of Co(II) |
title_short |
Development of a flow-through optosensor for determination of Co(II) |
title_full |
Development of a flow-through optosensor for determination of Co(II) |
title_fullStr |
Development of a flow-through optosensor for determination of Co(II) |
title_full_unstemmed |
Development of a flow-through optosensor for determination of Co(II) |
title_sort |
development of a flow-through optosensor for determination of co(ii) |
publisher |
Elsevier |
publishDate |
2008 |
url |
http://psasir.upm.edu.my/id/eprint/5826/1/Development%20of%20a%20flow-through%20optosensor%20for%20determination%20of%20Co%28II%29.pdf http://psasir.upm.edu.my/id/eprint/5826/ http://dx.doi.org/10.1016/j.saa.2007.04.015 |
_version_ |
1643823305514287104 |
score |
13.214268 |