Sensitivity study of graphene nanoribbon with NH3 at room temperature

This study presents the sensitivity of graphene nanoribbon (GNR) when exposed to ammonia gas at room temperature. Alumina were used as a substrate and coated with GNR as sensing film for ammonia gas detection. Four different concentration of GNR in the category of maximum, high, low, and minimum wer...

Full description

Saved in:
Bibliographic Details
Main Authors: Hamidon, Mohd Nizar, Sim, Guan Ling, Usman, Kamilu Iman
Format: Article
Language:English
Published: Universiti Putra Malaysia Press 2017
Online Access:http://psasir.upm.edu.my/id/eprint/55888/1/30-JTS%28S%29-0144-2016-4thProof.pdf
http://psasir.upm.edu.my/id/eprint/55888/
http://www.pertanika.upm.edu.my/Pertanika%20PAPERS/JST%20Vol.%2025%20(S)%20Feb.%202017/30-JTS(S)-0144-2016-4thProof.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.55888
record_format eprints
spelling my.upm.eprints.558882017-07-05T03:32:50Z http://psasir.upm.edu.my/id/eprint/55888/ Sensitivity study of graphene nanoribbon with NH3 at room temperature Hamidon, Mohd Nizar Sim, Guan Ling Usman, Kamilu Iman This study presents the sensitivity of graphene nanoribbon (GNR) when exposed to ammonia gas at room temperature. Alumina were used as a substrate and coated with GNR as sensing film for ammonia gas detection. Four different concentration of GNR in the category of maximum, high, low, and minimum were prepared. Each category of GNR will be dispersed on alumina substrate with area of 1cm² and 4cm². 30nm of gold contacts are sputtered on both ends of the sensing film. The ammonia gas can be detected by measuring the changes in resistance. The GNR as ammonia sensor shows good responses at room temperature. In repeatability test, maximum GNR shows least variation when exposed to ammonia with the value of 1.01% (4cm²) and 2.12% (1cm²). In a sensitivity test, 0.25% to 1.00% of ammonia gas was used and tested on maximum GNR. Maximum GNR on 4cm² substrate shows higher sensitivity as compared to 1cm². Reaction time of GNR on ammonia gas decreased as the concentration of ammonia increased. Larger surface area of sensing element required lesser reaction time. Universiti Putra Malaysia Press 2017 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/55888/1/30-JTS%28S%29-0144-2016-4thProof.pdf Hamidon, Mohd Nizar and Sim, Guan Ling and Usman, Kamilu Iman (2017) Sensitivity study of graphene nanoribbon with NH3 at room temperature. Pertanika Journal of Science & Technology, 25 (spec. Feb.). pp. 259-266. ISSN 0128-7680; ESSN: 2231-8526 http://www.pertanika.upm.edu.my/Pertanika%20PAPERS/JST%20Vol.%2025%20(S)%20Feb.%202017/30-JTS(S)-0144-2016-4thProof.pdf
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description This study presents the sensitivity of graphene nanoribbon (GNR) when exposed to ammonia gas at room temperature. Alumina were used as a substrate and coated with GNR as sensing film for ammonia gas detection. Four different concentration of GNR in the category of maximum, high, low, and minimum were prepared. Each category of GNR will be dispersed on alumina substrate with area of 1cm² and 4cm². 30nm of gold contacts are sputtered on both ends of the sensing film. The ammonia gas can be detected by measuring the changes in resistance. The GNR as ammonia sensor shows good responses at room temperature. In repeatability test, maximum GNR shows least variation when exposed to ammonia with the value of 1.01% (4cm²) and 2.12% (1cm²). In a sensitivity test, 0.25% to 1.00% of ammonia gas was used and tested on maximum GNR. Maximum GNR on 4cm² substrate shows higher sensitivity as compared to 1cm². Reaction time of GNR on ammonia gas decreased as the concentration of ammonia increased. Larger surface area of sensing element required lesser reaction time.
format Article
author Hamidon, Mohd Nizar
Sim, Guan Ling
Usman, Kamilu Iman
spellingShingle Hamidon, Mohd Nizar
Sim, Guan Ling
Usman, Kamilu Iman
Sensitivity study of graphene nanoribbon with NH3 at room temperature
author_facet Hamidon, Mohd Nizar
Sim, Guan Ling
Usman, Kamilu Iman
author_sort Hamidon, Mohd Nizar
title Sensitivity study of graphene nanoribbon with NH3 at room temperature
title_short Sensitivity study of graphene nanoribbon with NH3 at room temperature
title_full Sensitivity study of graphene nanoribbon with NH3 at room temperature
title_fullStr Sensitivity study of graphene nanoribbon with NH3 at room temperature
title_full_unstemmed Sensitivity study of graphene nanoribbon with NH3 at room temperature
title_sort sensitivity study of graphene nanoribbon with nh3 at room temperature
publisher Universiti Putra Malaysia Press
publishDate 2017
url http://psasir.upm.edu.my/id/eprint/55888/1/30-JTS%28S%29-0144-2016-4thProof.pdf
http://psasir.upm.edu.my/id/eprint/55888/
http://www.pertanika.upm.edu.my/Pertanika%20PAPERS/JST%20Vol.%2025%20(S)%20Feb.%202017/30-JTS(S)-0144-2016-4thProof.pdf
_version_ 1643836027622653952
score 13.160551