DC-link capacitor voltage regulation with effort-reduction fuzzy logic control for three-level inverter-based shunt active power filter

Shunt active power filter (SAPF) is the most effective solution for current harmonics. In its controller, DC-link capacitor voltage regulation algorithm with either proportional-integral (PI) or fuzzy logic control (FLC) technique has played a significant role in maintaining a constant DC voltage ac...

Full description

Saved in:
Bibliographic Details
Main Authors: Mailah, Nashiren Farzilah, Yap, Hoon, Mohd Radzi, Mohd Amran
Format: Article
Language:English
Published: Universiti Putra Malaysia Press 2017
Online Access:http://psasir.upm.edu.my/id/eprint/55863/1/2-JTS%28S%29-0116-2016-4thProof.pdf
http://psasir.upm.edu.my/id/eprint/55863/
http://www.pertanika.upm.edu.my/Pertanika%20PAPERS/JST%20Vol.%2025%20(S)%20Feb.%202017/2-JTS(S)-0116-2016-4thProof.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.55863
record_format eprints
spelling my.upm.eprints.558632017-06-30T09:49:49Z http://psasir.upm.edu.my/id/eprint/55863/ DC-link capacitor voltage regulation with effort-reduction fuzzy logic control for three-level inverter-based shunt active power filter Mailah, Nashiren Farzilah Yap, Hoon Mohd Radzi, Mohd Amran Shunt active power filter (SAPF) is the most effective solution for current harmonics. In its controller, DC-link capacitor voltage regulation algorithm with either proportional-integral (PI) or fuzzy logic control (FLC) technique has played a significant role in maintaining a constant DC voltage across all the DC-link capacitors. However, PI technique performs poorly with high overshoot and significant time delay under dynamic state conditions, as its parameters are difficult to be tuned without requiring complete knowledge of the designated system. Although FLC technique has been developed to overcome limitations of PI technique, it is mostly developed with high complexity thereby increases computational burden of the designed controller. This paper presents a fuzzy-based DC-link capacitor voltage regulation algorithm with reduced computational efforts to enhance performance of three-phase three-level neutral-point diode clamped (NPC) inverter-based SAPF in overall DC-link voltage regulation. The proposed method is called effort-reduction FLC technique. The proposed algorithm is developed and evaluated in MATLAB-Simulink. Moreover, conventional algorithm with PI technique is tested for comparison purposes. Simulation results have confirmed improvement achieved by the proposed algorithm in comparison to the conventional algorithm. Universiti Putra Malaysia Press 2017 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/55863/1/2-JTS%28S%29-0116-2016-4thProof.pdf Mailah, Nashiren Farzilah and Yap, Hoon and Mohd Radzi, Mohd Amran (2017) DC-link capacitor voltage regulation with effort-reduction fuzzy logic control for three-level inverter-based shunt active power filter. Pertanika Journal of Science & Technology, 25 (spec. Feb.). pp. 11-20. ISSN 0128-7680; ESSN: 2231-8526 http://www.pertanika.upm.edu.my/Pertanika%20PAPERS/JST%20Vol.%2025%20(S)%20Feb.%202017/2-JTS(S)-0116-2016-4thProof.pdf
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description Shunt active power filter (SAPF) is the most effective solution for current harmonics. In its controller, DC-link capacitor voltage regulation algorithm with either proportional-integral (PI) or fuzzy logic control (FLC) technique has played a significant role in maintaining a constant DC voltage across all the DC-link capacitors. However, PI technique performs poorly with high overshoot and significant time delay under dynamic state conditions, as its parameters are difficult to be tuned without requiring complete knowledge of the designated system. Although FLC technique has been developed to overcome limitations of PI technique, it is mostly developed with high complexity thereby increases computational burden of the designed controller. This paper presents a fuzzy-based DC-link capacitor voltage regulation algorithm with reduced computational efforts to enhance performance of three-phase three-level neutral-point diode clamped (NPC) inverter-based SAPF in overall DC-link voltage regulation. The proposed method is called effort-reduction FLC technique. The proposed algorithm is developed and evaluated in MATLAB-Simulink. Moreover, conventional algorithm with PI technique is tested for comparison purposes. Simulation results have confirmed improvement achieved by the proposed algorithm in comparison to the conventional algorithm.
format Article
author Mailah, Nashiren Farzilah
Yap, Hoon
Mohd Radzi, Mohd Amran
spellingShingle Mailah, Nashiren Farzilah
Yap, Hoon
Mohd Radzi, Mohd Amran
DC-link capacitor voltage regulation with effort-reduction fuzzy logic control for three-level inverter-based shunt active power filter
author_facet Mailah, Nashiren Farzilah
Yap, Hoon
Mohd Radzi, Mohd Amran
author_sort Mailah, Nashiren Farzilah
title DC-link capacitor voltage regulation with effort-reduction fuzzy logic control for three-level inverter-based shunt active power filter
title_short DC-link capacitor voltage regulation with effort-reduction fuzzy logic control for three-level inverter-based shunt active power filter
title_full DC-link capacitor voltage regulation with effort-reduction fuzzy logic control for three-level inverter-based shunt active power filter
title_fullStr DC-link capacitor voltage regulation with effort-reduction fuzzy logic control for three-level inverter-based shunt active power filter
title_full_unstemmed DC-link capacitor voltage regulation with effort-reduction fuzzy logic control for three-level inverter-based shunt active power filter
title_sort dc-link capacitor voltage regulation with effort-reduction fuzzy logic control for three-level inverter-based shunt active power filter
publisher Universiti Putra Malaysia Press
publishDate 2017
url http://psasir.upm.edu.my/id/eprint/55863/1/2-JTS%28S%29-0116-2016-4thProof.pdf
http://psasir.upm.edu.my/id/eprint/55863/
http://www.pertanika.upm.edu.my/Pertanika%20PAPERS/JST%20Vol.%2025%20(S)%20Feb.%202017/2-JTS(S)-0116-2016-4thProof.pdf
_version_ 1643836020611874816
score 13.160551