Weakest bus frequency identification of power system via TFDI

One of the concerns in power system preventive control and security assessment is to find the point where the voltage and frequency collapse and when the system forces a severe disturbance. Identifying the weakest bus in a power system is an essential aspect of planning, optimising and post-event an...

Full description

Saved in:
Bibliographic Details
Main Authors: Al Mentefik, Athraa Iessa Shaaban, Abdul Wahab, Noor Izzri, Mariun, Norman
Format: Article
Language:English
Published: Universiti Putra Malaysia Press 2017
Online Access:http://psasir.upm.edu.my/id/eprint/55850/1/12-JTS%28S%29-0126-2016-4thProof.pdf
http://psasir.upm.edu.my/id/eprint/55850/
http://www.pertanika.upm.edu.my/Pertanika%20PAPERS/JST%20Vol.%2025%20(S)%20Feb.%202017/12-JTS(S)-0126-2016-4thProof.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.55850
record_format eprints
spelling my.upm.eprints.558502017-07-05T03:57:12Z http://psasir.upm.edu.my/id/eprint/55850/ Weakest bus frequency identification of power system via TFDI Al Mentefik, Athraa Iessa Shaaban Abdul Wahab, Noor Izzri Mariun, Norman One of the concerns in power system preventive control and security assessment is to find the point where the voltage and frequency collapse and when the system forces a severe disturbance. Identifying the weakest bus in a power system is an essential aspect of planning, optimising and post-event analysing procedures. This paper proposes an approach to identify the weakest bus from the frequency security viewpoint. The transient frequency deviation index for the individual buses is used as the weakest bus identification as well as a frequency security indicator. This approach will help to determine the bus with the worst deviation, which helps to analyse the system disturbance, takes proper control action to prevent frequency failure, and most importantly, observes consumer frequency. The approach is applied to the WSCC 9 bus test system to show the feasibility of the method. Universiti Putra Malaysia Press 2017 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/55850/1/12-JTS%28S%29-0126-2016-4thProof.pdf Al Mentefik, Athraa Iessa Shaaban and Abdul Wahab, Noor Izzri and Mariun, Norman (2017) Weakest bus frequency identification of power system via TFDI. Pertanika Journal of Science & Technology, 25 (spec. Feb.). pp. 97-104. ISSN 0128-7680; ESSN: 2231-8526 http://www.pertanika.upm.edu.my/Pertanika%20PAPERS/JST%20Vol.%2025%20(S)%20Feb.%202017/12-JTS(S)-0126-2016-4thProof.pdf
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description One of the concerns in power system preventive control and security assessment is to find the point where the voltage and frequency collapse and when the system forces a severe disturbance. Identifying the weakest bus in a power system is an essential aspect of planning, optimising and post-event analysing procedures. This paper proposes an approach to identify the weakest bus from the frequency security viewpoint. The transient frequency deviation index for the individual buses is used as the weakest bus identification as well as a frequency security indicator. This approach will help to determine the bus with the worst deviation, which helps to analyse the system disturbance, takes proper control action to prevent frequency failure, and most importantly, observes consumer frequency. The approach is applied to the WSCC 9 bus test system to show the feasibility of the method.
format Article
author Al Mentefik, Athraa Iessa Shaaban
Abdul Wahab, Noor Izzri
Mariun, Norman
spellingShingle Al Mentefik, Athraa Iessa Shaaban
Abdul Wahab, Noor Izzri
Mariun, Norman
Weakest bus frequency identification of power system via TFDI
author_facet Al Mentefik, Athraa Iessa Shaaban
Abdul Wahab, Noor Izzri
Mariun, Norman
author_sort Al Mentefik, Athraa Iessa Shaaban
title Weakest bus frequency identification of power system via TFDI
title_short Weakest bus frequency identification of power system via TFDI
title_full Weakest bus frequency identification of power system via TFDI
title_fullStr Weakest bus frequency identification of power system via TFDI
title_full_unstemmed Weakest bus frequency identification of power system via TFDI
title_sort weakest bus frequency identification of power system via tfdi
publisher Universiti Putra Malaysia Press
publishDate 2017
url http://psasir.upm.edu.my/id/eprint/55850/1/12-JTS%28S%29-0126-2016-4thProof.pdf
http://psasir.upm.edu.my/id/eprint/55850/
http://www.pertanika.upm.edu.my/Pertanika%20PAPERS/JST%20Vol.%2025%20(S)%20Feb.%202017/12-JTS(S)-0126-2016-4thProof.pdf
_version_ 1643836016737386496
score 13.211869