Fluorometric immunoassay for detecting the plant virus Citrus tristeza using carbon nanoparticles acting as quenchers and antibodies labeled with CdTe quantum dots

Cadmium-telluride quantum dots (QDs) were conjugated to an antibody (Ab) against Citrus tristeza virus (CTV), while the coat protein (CP) of the CTV was immobilized on the surface of carbon nanoparticles (CNPs). Following immunobinding of the QD-Ab and the CP-loaded CNPs, the fluorescence of the CdT...

Full description

Saved in:
Bibliographic Details
Main Authors: Shojaei, Taha Roodbar, Mohd Salleh, Mohamad Amran, Sijam, Kamaruzaman, Abdul Rahim, Raha, Mohsenifar, Afshin, Safarnejad, Reza, Tabatabaei, Meisam
Format: Article
Language:English
Published: Springer Verlag 2016
Online Access:http://psasir.upm.edu.my/id/eprint/54334/1/Fluorometric%20immunoassay%20for%20detecting%20the%20plant%20virus%20Citrus%20tristeza%20.pdf
http://psasir.upm.edu.my/id/eprint/54334/
https://link.springer.com/article/10.1007/s00604-016-1867-7
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.54334
record_format eprints
spelling my.upm.eprints.543342018-03-14T01:11:12Z http://psasir.upm.edu.my/id/eprint/54334/ Fluorometric immunoassay for detecting the plant virus Citrus tristeza using carbon nanoparticles acting as quenchers and antibodies labeled with CdTe quantum dots Shojaei, Taha Roodbar Mohd Salleh, Mohamad Amran Sijam, Kamaruzaman Abdul Rahim, Raha Mohsenifar, Afshin Safarnejad, Reza Tabatabaei, Meisam Cadmium-telluride quantum dots (QDs) were conjugated to an antibody (Ab) against Citrus tristeza virus (CTV), while the coat protein (CP) of the CTV was immobilized on the surface of carbon nanoparticles (CNPs). Following immunobinding of the QD-Ab and the CP-loaded CNPs, the fluorescence of the CdTe QDs was quenched by the CNPs. This effect was exploited to design a detection assay for the CTV which was found more sensitive and specific than the existing enzyme linked immunosorbent assay (ELISA). The limit of detection was measured at about 220 ng⋅ mL‾1 of CTV. The Stern-Volmer plot of the CNPs-QD quencher pair showed a positive deviation from linearity which was ascribed to the presence of both static and dynamic quenching. Springer Verlag 2016-07 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/54334/1/Fluorometric%20immunoassay%20for%20detecting%20the%20plant%20virus%20Citrus%20tristeza%20.pdf Shojaei, Taha Roodbar and Mohd Salleh, Mohamad Amran and Sijam, Kamaruzaman and Abdul Rahim, Raha and Mohsenifar, Afshin and Safarnejad, Reza and Tabatabaei, Meisam (2016) Fluorometric immunoassay for detecting the plant virus Citrus tristeza using carbon nanoparticles acting as quenchers and antibodies labeled with CdTe quantum dots. Microchimica Acta, 183 (7/July). pp. 2277-2287. ISSN 0026-3672; ESSN:1436-5073 https://link.springer.com/article/10.1007/s00604-016-1867-7 10.1007/s00604-016-1867-7
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description Cadmium-telluride quantum dots (QDs) were conjugated to an antibody (Ab) against Citrus tristeza virus (CTV), while the coat protein (CP) of the CTV was immobilized on the surface of carbon nanoparticles (CNPs). Following immunobinding of the QD-Ab and the CP-loaded CNPs, the fluorescence of the CdTe QDs was quenched by the CNPs. This effect was exploited to design a detection assay for the CTV which was found more sensitive and specific than the existing enzyme linked immunosorbent assay (ELISA). The limit of detection was measured at about 220 ng⋅ mL‾1 of CTV. The Stern-Volmer plot of the CNPs-QD quencher pair showed a positive deviation from linearity which was ascribed to the presence of both static and dynamic quenching.
format Article
author Shojaei, Taha Roodbar
Mohd Salleh, Mohamad Amran
Sijam, Kamaruzaman
Abdul Rahim, Raha
Mohsenifar, Afshin
Safarnejad, Reza
Tabatabaei, Meisam
spellingShingle Shojaei, Taha Roodbar
Mohd Salleh, Mohamad Amran
Sijam, Kamaruzaman
Abdul Rahim, Raha
Mohsenifar, Afshin
Safarnejad, Reza
Tabatabaei, Meisam
Fluorometric immunoassay for detecting the plant virus Citrus tristeza using carbon nanoparticles acting as quenchers and antibodies labeled with CdTe quantum dots
author_facet Shojaei, Taha Roodbar
Mohd Salleh, Mohamad Amran
Sijam, Kamaruzaman
Abdul Rahim, Raha
Mohsenifar, Afshin
Safarnejad, Reza
Tabatabaei, Meisam
author_sort Shojaei, Taha Roodbar
title Fluorometric immunoassay for detecting the plant virus Citrus tristeza using carbon nanoparticles acting as quenchers and antibodies labeled with CdTe quantum dots
title_short Fluorometric immunoassay for detecting the plant virus Citrus tristeza using carbon nanoparticles acting as quenchers and antibodies labeled with CdTe quantum dots
title_full Fluorometric immunoassay for detecting the plant virus Citrus tristeza using carbon nanoparticles acting as quenchers and antibodies labeled with CdTe quantum dots
title_fullStr Fluorometric immunoassay for detecting the plant virus Citrus tristeza using carbon nanoparticles acting as quenchers and antibodies labeled with CdTe quantum dots
title_full_unstemmed Fluorometric immunoassay for detecting the plant virus Citrus tristeza using carbon nanoparticles acting as quenchers and antibodies labeled with CdTe quantum dots
title_sort fluorometric immunoassay for detecting the plant virus citrus tristeza using carbon nanoparticles acting as quenchers and antibodies labeled with cdte quantum dots
publisher Springer Verlag
publishDate 2016
url http://psasir.upm.edu.my/id/eprint/54334/1/Fluorometric%20immunoassay%20for%20detecting%20the%20plant%20virus%20Citrus%20tristeza%20.pdf
http://psasir.upm.edu.my/id/eprint/54334/
https://link.springer.com/article/10.1007/s00604-016-1867-7
_version_ 1643835617193230336
score 13.18916