Influence Of Air Exchange Effectiveness On Thermal Comfort In Malaysia

Influence of air exchange rate and air exchange effectiveness on thermal comfort has not been investigated in the world at all and are, therefore, not well understood. The main objective of this research is to investigate effects of ventilation parameters on thermal comfort and assessing these influ...

Full description

Saved in:
Bibliographic Details
Main Author: Daghigh, Roonak
Format: Thesis
Language:English
English
Published: 2008
Online Access:http://psasir.upm.edu.my/id/eprint/5347/1/FK_2008_6.pdf
http://psasir.upm.edu.my/id/eprint/5347/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.5347
record_format eprints
spelling my.upm.eprints.53472013-05-27T07:22:10Z http://psasir.upm.edu.my/id/eprint/5347/ Influence Of Air Exchange Effectiveness On Thermal Comfort In Malaysia Daghigh, Roonak Influence of air exchange rate and air exchange effectiveness on thermal comfort has not been investigated in the world at all and are, therefore, not well understood. The main objective of this research is to investigate effects of ventilation parameters on thermal comfort and assessing these influences through the variable windows-door opening arrangements. To determine the windows-door opening performance in terms of ventilation air flow rate 28 opening configurations have been considered. The combination of windows-door opening arrangements was carried out in office room. Thermal comfort field experiments and ventilation study were conducted in both naturally ventilated and air conditioned office. Age of air, Air exchange rate (ACH), Air exchange effectiveness (AEE), Predicted Mean Vote (PMV) and predicted Percentage of Dissatisfied (PPD) for each condition were calculated. Apart from common thermal comfort factors such as air dry bulb temperature, relative humidity,mean radiant temperature, air velocity, metabolic rate and thermal resistance, two new factors were considered, i.e., ACH and AEE. The subjective survey involved questions on the thermal environmental perception and indoor air quality for office occupants. The results yielded from subjective and objective approach were used to formulate a method for simulation of office buildings to include the effects of opening arrangements and ventilation parameters on thermal comfort. These results showed that for naturally ventilated and air conditioned office room twelve linear regression equations of PMV versus ACH and AEE can be derived. Through those yielded equations it has been determined that the Coefficient of Correlation (R2) obtained for PMV average, maximum and minimum versus ACH are 96.5, 93.9, 97.3% and 94.3, 89.9, 86.6%, respectively. The Coefficient of Correlation (R2) obtained for PMV average, maximum and minimum versus AEE are 74.9, 70.7, 76.9% and 88.7, 76.5, 86.7%, respectively for naturally and mechanically ventilated office room. P values (significance levels) for ANOVA test and t-test are less than 0.05, which means that the variation explained by these equations not due to chance and there are significant correlation between PMV and ACH and high correlation between PMV and AEE in naturally and mechanically ventilated office room. It has been observed that with increment in ACH in order to meet ASHRAE Standard 62 requirements, PMV values are closed to ISO 7730 comfort range, and by approaching the AEE to value of one, PMV values are again closed to ISO 7730 comfort range in naturally and mechanically ventilated office room. This study has shown that there are relationship between ACH, AEE and thermal comfort. Thermal comfort is to a great extent influenced by ACH and AEE which go beyond the six factors which have been taken into account in PMV modeling. It is believed that they have contributed in some positive ways to the higher level of thermal comfort. 2008 Thesis NonPeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/5347/1/FK_2008_6.pdf Daghigh, Roonak (2008) Influence Of Air Exchange Effectiveness On Thermal Comfort In Malaysia. Masters thesis, Universiti Putra Malaysia. English
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
English
description Influence of air exchange rate and air exchange effectiveness on thermal comfort has not been investigated in the world at all and are, therefore, not well understood. The main objective of this research is to investigate effects of ventilation parameters on thermal comfort and assessing these influences through the variable windows-door opening arrangements. To determine the windows-door opening performance in terms of ventilation air flow rate 28 opening configurations have been considered. The combination of windows-door opening arrangements was carried out in office room. Thermal comfort field experiments and ventilation study were conducted in both naturally ventilated and air conditioned office. Age of air, Air exchange rate (ACH), Air exchange effectiveness (AEE), Predicted Mean Vote (PMV) and predicted Percentage of Dissatisfied (PPD) for each condition were calculated. Apart from common thermal comfort factors such as air dry bulb temperature, relative humidity,mean radiant temperature, air velocity, metabolic rate and thermal resistance, two new factors were considered, i.e., ACH and AEE. The subjective survey involved questions on the thermal environmental perception and indoor air quality for office occupants. The results yielded from subjective and objective approach were used to formulate a method for simulation of office buildings to include the effects of opening arrangements and ventilation parameters on thermal comfort. These results showed that for naturally ventilated and air conditioned office room twelve linear regression equations of PMV versus ACH and AEE can be derived. Through those yielded equations it has been determined that the Coefficient of Correlation (R2) obtained for PMV average, maximum and minimum versus ACH are 96.5, 93.9, 97.3% and 94.3, 89.9, 86.6%, respectively. The Coefficient of Correlation (R2) obtained for PMV average, maximum and minimum versus AEE are 74.9, 70.7, 76.9% and 88.7, 76.5, 86.7%, respectively for naturally and mechanically ventilated office room. P values (significance levels) for ANOVA test and t-test are less than 0.05, which means that the variation explained by these equations not due to chance and there are significant correlation between PMV and ACH and high correlation between PMV and AEE in naturally and mechanically ventilated office room. It has been observed that with increment in ACH in order to meet ASHRAE Standard 62 requirements, PMV values are closed to ISO 7730 comfort range, and by approaching the AEE to value of one, PMV values are again closed to ISO 7730 comfort range in naturally and mechanically ventilated office room. This study has shown that there are relationship between ACH, AEE and thermal comfort. Thermal comfort is to a great extent influenced by ACH and AEE which go beyond the six factors which have been taken into account in PMV modeling. It is believed that they have contributed in some positive ways to the higher level of thermal comfort.
format Thesis
author Daghigh, Roonak
spellingShingle Daghigh, Roonak
Influence Of Air Exchange Effectiveness On Thermal Comfort In Malaysia
author_facet Daghigh, Roonak
author_sort Daghigh, Roonak
title Influence Of Air Exchange Effectiveness On Thermal Comfort In Malaysia
title_short Influence Of Air Exchange Effectiveness On Thermal Comfort In Malaysia
title_full Influence Of Air Exchange Effectiveness On Thermal Comfort In Malaysia
title_fullStr Influence Of Air Exchange Effectiveness On Thermal Comfort In Malaysia
title_full_unstemmed Influence Of Air Exchange Effectiveness On Thermal Comfort In Malaysia
title_sort influence of air exchange effectiveness on thermal comfort in malaysia
publishDate 2008
url http://psasir.upm.edu.my/id/eprint/5347/1/FK_2008_6.pdf
http://psasir.upm.edu.my/id/eprint/5347/
_version_ 1643823163630419968