Application of the pyroelectric sensor for study of porosity effect on thermal diffusivity of nickel copper zink ferrite

An investigation was carried out to study the effect of the porosity on thermal diffusivity of Nickel Copper Zinc Ferrite. The experimental technique employed to measure thermal diffusivity was the photoflash technique, and the measurements were carried out at room temperature. The heating source co...

Full description

Saved in:
Bibliographic Details
Main Authors: Grozescu, Ionel Valeriu, Abd. Moksin, Mohd Maarof, Haydari, Mehdi, Yahaya, N., Mat Yunus, Wan Mahmood
Format: Conference or Workshop Item
Language:English
Published: IEEE 2003
Online Access:http://psasir.upm.edu.my/id/eprint/48308/1/Application%20of%20the%20pyroelectric%20sensor%20for%20study%20of%20porosity%20effect%20on%20thermal%20diffusivity%20of%20nickel%20copper%20zink%20ferrite.pdf
http://psasir.upm.edu.my/id/eprint/48308/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.48308
record_format eprints
spelling my.upm.eprints.483082016-09-22T08:43:11Z http://psasir.upm.edu.my/id/eprint/48308/ Application of the pyroelectric sensor for study of porosity effect on thermal diffusivity of nickel copper zink ferrite Grozescu, Ionel Valeriu Abd. Moksin, Mohd Maarof Haydari, Mehdi Yahaya, N. Mat Yunus, Wan Mahmood An investigation was carried out to study the effect of the porosity on thermal diffusivity of Nickel Copper Zinc Ferrite. The experimental technique employed to measure thermal diffusivity was the photoflash technique, and the measurements were carried out at room temperature. The heating source consists of camera flash having approximately 5ms pulse duration and a thin film of polyvinylidene difluoride (PVDF) attached to the back of the samples was used as detector. Six different porosity levels were obtained by varying the grinding time following the presintering process and preceding the sintering process at 1350°C. The porosity range obtained for the Ni0.3Cu0.1Zn0.6Fe2O4 samples was 1.8-7%. The thermal diffusivity was determined from the experimental thermal transient signal. For the fitting of the experimental results, the analytical model used was based on the approximation that the pulse duration of the camera flash can be considered as Dirac-δ function. Thermal diffusivity values for Ni0.3Cu0.1Zn0.6Fe2O4 samples were in the range (7.8-8.7) × 10-7 m2/s. IEEE 2003 Conference or Workshop Item PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/48308/1/Application%20of%20the%20pyroelectric%20sensor%20for%20study%20of%20porosity%20effect%20on%20thermal%20diffusivity%20of%20nickel%20copper%20zink%20ferrite.pdf Grozescu, Ionel Valeriu and Abd. Moksin, Mohd Maarof and Haydari, Mehdi and Yahaya, N. and Mat Yunus, Wan Mahmood (2003) Application of the pyroelectric sensor for study of porosity effect on thermal diffusivity of nickel copper zink ferrite. In: 2003 Asian Conference on Sensors (AsiaSENSE 2003), Malaysia. (pp. 65-68). 10.1109/ASENSE.2003.1224994
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description An investigation was carried out to study the effect of the porosity on thermal diffusivity of Nickel Copper Zinc Ferrite. The experimental technique employed to measure thermal diffusivity was the photoflash technique, and the measurements were carried out at room temperature. The heating source consists of camera flash having approximately 5ms pulse duration and a thin film of polyvinylidene difluoride (PVDF) attached to the back of the samples was used as detector. Six different porosity levels were obtained by varying the grinding time following the presintering process and preceding the sintering process at 1350°C. The porosity range obtained for the Ni0.3Cu0.1Zn0.6Fe2O4 samples was 1.8-7%. The thermal diffusivity was determined from the experimental thermal transient signal. For the fitting of the experimental results, the analytical model used was based on the approximation that the pulse duration of the camera flash can be considered as Dirac-δ function. Thermal diffusivity values for Ni0.3Cu0.1Zn0.6Fe2O4 samples were in the range (7.8-8.7) × 10-7 m2/s.
format Conference or Workshop Item
author Grozescu, Ionel Valeriu
Abd. Moksin, Mohd Maarof
Haydari, Mehdi
Yahaya, N.
Mat Yunus, Wan Mahmood
spellingShingle Grozescu, Ionel Valeriu
Abd. Moksin, Mohd Maarof
Haydari, Mehdi
Yahaya, N.
Mat Yunus, Wan Mahmood
Application of the pyroelectric sensor for study of porosity effect on thermal diffusivity of nickel copper zink ferrite
author_facet Grozescu, Ionel Valeriu
Abd. Moksin, Mohd Maarof
Haydari, Mehdi
Yahaya, N.
Mat Yunus, Wan Mahmood
author_sort Grozescu, Ionel Valeriu
title Application of the pyroelectric sensor for study of porosity effect on thermal diffusivity of nickel copper zink ferrite
title_short Application of the pyroelectric sensor for study of porosity effect on thermal diffusivity of nickel copper zink ferrite
title_full Application of the pyroelectric sensor for study of porosity effect on thermal diffusivity of nickel copper zink ferrite
title_fullStr Application of the pyroelectric sensor for study of porosity effect on thermal diffusivity of nickel copper zink ferrite
title_full_unstemmed Application of the pyroelectric sensor for study of porosity effect on thermal diffusivity of nickel copper zink ferrite
title_sort application of the pyroelectric sensor for study of porosity effect on thermal diffusivity of nickel copper zink ferrite
publisher IEEE
publishDate 2003
url http://psasir.upm.edu.my/id/eprint/48308/1/Application%20of%20the%20pyroelectric%20sensor%20for%20study%20of%20porosity%20effect%20on%20thermal%20diffusivity%20of%20nickel%20copper%20zink%20ferrite.pdf
http://psasir.upm.edu.my/id/eprint/48308/
_version_ 1643834136982454272
score 13.160551