Study of EDC/NHS immobilization for plumbous detection using surface plasmon resonance

The presence of plumbous (Pb2+) in Irrigation water is harmful for the environment as well as human health. Herein, a simple yet effective sensor for Pb2+ detection is presented utilizing a surface plasmon resonance technique. The proposed sensor consists of a combination of 1-ethyl-3-(3-dimethylami...

Full description

Saved in:
Bibliographic Details
Main Authors: Alwahib, Ali Abdulkhaleq, Sadrolhosseini, Amir Reza, Lim, Hong Ngee, Yaacob, Mohd Hanif, Abu Bakar, Muhammad Hafiz, Mahdi, Mohd Adzir
Format: Article
Language:English
Published: Penerbit UTM Press 2016
Online Access:http://psasir.upm.edu.my/id/eprint/47409/1/Study%20of%20EDCNHS%20immobilization%20for%20plumbous%20detection%20using%20surface%20plasmon%20resonance.pdf
http://psasir.upm.edu.my/id/eprint/47409/
http://www.jurnalteknologi.utm.my/index.php/jurnalteknologi/article/view/7526
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.47409
record_format eprints
spelling my.upm.eprints.474092016-05-19T07:13:24Z http://psasir.upm.edu.my/id/eprint/47409/ Study of EDC/NHS immobilization for plumbous detection using surface plasmon resonance Alwahib, Ali Abdulkhaleq Sadrolhosseini, Amir Reza Lim, Hong Ngee Yaacob, Mohd Hanif Abu Bakar, Muhammad Hafiz Mahdi, Mohd Adzir The presence of plumbous (Pb2+) in Irrigation water is harmful for the environment as well as human health. Herein, a simple yet effective sensor for Pb2+ detection is presented utilizing a surface plasmon resonance technique. The proposed sensor consists of a combination of 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS) were attached to a gold layer offers a new option for heavy metal detection. The EDC/NHS works as a sensing layer that able to detect Pb2+ down to 15 ppm that matches with the United States Environment Protection Agency. Penerbit UTM Press 2016 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/47409/1/Study%20of%20EDCNHS%20immobilization%20for%20plumbous%20detection%20using%20surface%20plasmon%20resonance.pdf Alwahib, Ali Abdulkhaleq and Sadrolhosseini, Amir Reza and Lim, Hong Ngee and Yaacob, Mohd Hanif and Abu Bakar, Muhammad Hafiz and Mahdi, Mohd Adzir (2016) Study of EDC/NHS immobilization for plumbous detection using surface plasmon resonance. Jurnal Teknologi (Sciences and Engineering), 78 (3). pp. 253-256. ISSN 0127-9696; ESSN: 2180-3722 http://www.jurnalteknologi.utm.my/index.php/jurnalteknologi/article/view/7526
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description The presence of plumbous (Pb2+) in Irrigation water is harmful for the environment as well as human health. Herein, a simple yet effective sensor for Pb2+ detection is presented utilizing a surface plasmon resonance technique. The proposed sensor consists of a combination of 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS) were attached to a gold layer offers a new option for heavy metal detection. The EDC/NHS works as a sensing layer that able to detect Pb2+ down to 15 ppm that matches with the United States Environment Protection Agency.
format Article
author Alwahib, Ali Abdulkhaleq
Sadrolhosseini, Amir Reza
Lim, Hong Ngee
Yaacob, Mohd Hanif
Abu Bakar, Muhammad Hafiz
Mahdi, Mohd Adzir
spellingShingle Alwahib, Ali Abdulkhaleq
Sadrolhosseini, Amir Reza
Lim, Hong Ngee
Yaacob, Mohd Hanif
Abu Bakar, Muhammad Hafiz
Mahdi, Mohd Adzir
Study of EDC/NHS immobilization for plumbous detection using surface plasmon resonance
author_facet Alwahib, Ali Abdulkhaleq
Sadrolhosseini, Amir Reza
Lim, Hong Ngee
Yaacob, Mohd Hanif
Abu Bakar, Muhammad Hafiz
Mahdi, Mohd Adzir
author_sort Alwahib, Ali Abdulkhaleq
title Study of EDC/NHS immobilization for plumbous detection using surface plasmon resonance
title_short Study of EDC/NHS immobilization for plumbous detection using surface plasmon resonance
title_full Study of EDC/NHS immobilization for plumbous detection using surface plasmon resonance
title_fullStr Study of EDC/NHS immobilization for plumbous detection using surface plasmon resonance
title_full_unstemmed Study of EDC/NHS immobilization for plumbous detection using surface plasmon resonance
title_sort study of edc/nhs immobilization for plumbous detection using surface plasmon resonance
publisher Penerbit UTM Press
publishDate 2016
url http://psasir.upm.edu.my/id/eprint/47409/1/Study%20of%20EDCNHS%20immobilization%20for%20plumbous%20detection%20using%20surface%20plasmon%20resonance.pdf
http://psasir.upm.edu.my/id/eprint/47409/
http://www.jurnalteknologi.utm.my/index.php/jurnalteknologi/article/view/7526
_version_ 1643833875141492736
score 13.160551