Pressure reduction on blood flow in aorta coronary sinus conduit

Numerical studies of blood flow system of aorta coronary sinus conduit were carried out using ANSYSTM CFD simulation. A different model of conduit, which differs in the inlet diameter, was investigated. The investigated inlet diameters are 3 mm, 4 mm and 5 mm. Pressure drop from 80 mmHg to 15 mmHg w...

Full description

Saved in:
Bibliographic Details
Main Authors: Hussain, Siti Aslina, Tan, Hong Tat, Abdul Hamid, Mohd Ismail, Abdullah, Norhafizah, Idris, Azni
Format: Article
Language:English
Published: Universiti Putra Malaysia Press 2012
Online Access:http://psasir.upm.edu.my/id/eprint/40477/1/19.%20Pressure%20Reduction%20on%20Blood%20Flow%20in%20Aorta%20Coronary.pdf
http://psasir.upm.edu.my/id/eprint/40477/
http://www.pertanika.upm.edu.my/Pertanika%20PAPERS/JST%20Vol.%2020%20%282%29%20Jul.%202012/13%20Pg%20347-353.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.40477
record_format eprints
spelling my.upm.eprints.404772015-11-04T04:33:10Z http://psasir.upm.edu.my/id/eprint/40477/ Pressure reduction on blood flow in aorta coronary sinus conduit Hussain, Siti Aslina Tan, Hong Tat Abdul Hamid, Mohd Ismail Abdullah, Norhafizah Idris, Azni Numerical studies of blood flow system of aorta coronary sinus conduit were carried out using ANSYSTM CFD simulation. A different model of conduit, which differs in the inlet diameter, was investigated. The investigated inlet diameters are 3 mm, 4 mm and 5 mm. Pressure drop from 80 mmHg to 15 mmHg was achieved for all the models. The comparison chart was produced to compare the pattern of pressure reduction as well as velocity distribution in each model. From the analysis of coronary sinus conduit, it was found that a narrow tube needs to be incorporated into the conduit produced. This is to induce a venturi effect to reduce the pressure drop of blood within a specific throat length. As conclusion, a model of 3 mm inlet and a throat diameter of 1.13 mm show satisfactory result for pressure reduction from 80 mmHg to 15 mmHg. This particular model also has a lower peak velocity at the inlet zone of the throat section, which is more preferable in terms of Reynolds number. Universiti Putra Malaysia Press 2012 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/40477/1/19.%20Pressure%20Reduction%20on%20Blood%20Flow%20in%20Aorta%20Coronary.pdf Hussain, Siti Aslina and Tan, Hong Tat and Abdul Hamid, Mohd Ismail and Abdullah, Norhafizah and Idris, Azni (2012) Pressure reduction on blood flow in aorta coronary sinus conduit. Pertanika Journal of Science & Technology, 20 (2). pp. 347-353. ISSN 0128-7680; ESSN: 2231-8526 http://www.pertanika.upm.edu.my/Pertanika%20PAPERS/JST%20Vol.%2020%20%282%29%20Jul.%202012/13%20Pg%20347-353.pdf
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description Numerical studies of blood flow system of aorta coronary sinus conduit were carried out using ANSYSTM CFD simulation. A different model of conduit, which differs in the inlet diameter, was investigated. The investigated inlet diameters are 3 mm, 4 mm and 5 mm. Pressure drop from 80 mmHg to 15 mmHg was achieved for all the models. The comparison chart was produced to compare the pattern of pressure reduction as well as velocity distribution in each model. From the analysis of coronary sinus conduit, it was found that a narrow tube needs to be incorporated into the conduit produced. This is to induce a venturi effect to reduce the pressure drop of blood within a specific throat length. As conclusion, a model of 3 mm inlet and a throat diameter of 1.13 mm show satisfactory result for pressure reduction from 80 mmHg to 15 mmHg. This particular model also has a lower peak velocity at the inlet zone of the throat section, which is more preferable in terms of Reynolds number.
format Article
author Hussain, Siti Aslina
Tan, Hong Tat
Abdul Hamid, Mohd Ismail
Abdullah, Norhafizah
Idris, Azni
spellingShingle Hussain, Siti Aslina
Tan, Hong Tat
Abdul Hamid, Mohd Ismail
Abdullah, Norhafizah
Idris, Azni
Pressure reduction on blood flow in aorta coronary sinus conduit
author_facet Hussain, Siti Aslina
Tan, Hong Tat
Abdul Hamid, Mohd Ismail
Abdullah, Norhafizah
Idris, Azni
author_sort Hussain, Siti Aslina
title Pressure reduction on blood flow in aorta coronary sinus conduit
title_short Pressure reduction on blood flow in aorta coronary sinus conduit
title_full Pressure reduction on blood flow in aorta coronary sinus conduit
title_fullStr Pressure reduction on blood flow in aorta coronary sinus conduit
title_full_unstemmed Pressure reduction on blood flow in aorta coronary sinus conduit
title_sort pressure reduction on blood flow in aorta coronary sinus conduit
publisher Universiti Putra Malaysia Press
publishDate 2012
url http://psasir.upm.edu.my/id/eprint/40477/1/19.%20Pressure%20Reduction%20on%20Blood%20Flow%20in%20Aorta%20Coronary.pdf
http://psasir.upm.edu.my/id/eprint/40477/
http://www.pertanika.upm.edu.my/Pertanika%20PAPERS/JST%20Vol.%2020%20%282%29%20Jul.%202012/13%20Pg%20347-353.pdf
_version_ 1643832727443603456
score 13.160551