Shunt active power filter: a review on phase synchronization control techniques

Owing to the destructive impacts of harmonic currents, the topic of reducing their impacts on power system has attracted tremendous research interests. In this regard, a shunt active power filter (SAPF) is recognized to be the most reliable instrument. It performs by first detecting the harmonic cur...

Full description

Saved in:
Bibliographic Details
Main Authors: Hoon, Yap, Mohd Radzi, Mohd Amran, Mohd Zainuri, Muhammad Ammirrul Atiqi, Md Zawawi, Mohamad Adzhar
Format: Article
Language:English
Published: MDPI 2019
Online Access:http://psasir.upm.edu.my/id/eprint/38327/1/38327.pdf
http://psasir.upm.edu.my/id/eprint/38327/
https://www.mdpi.com/2079-9292/8/7/791
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.38327
record_format eprints
spelling my.upm.eprints.383272020-05-04T16:17:45Z http://psasir.upm.edu.my/id/eprint/38327/ Shunt active power filter: a review on phase synchronization control techniques Hoon, Yap Mohd Radzi, Mohd Amran Mohd Zainuri, Muhammad Ammirrul Atiqi Md Zawawi, Mohamad Adzhar Owing to the destructive impacts of harmonic currents, the topic of reducing their impacts on power system has attracted tremendous research interests. In this regard, a shunt active power filter (SAPF) is recognized to be the most reliable instrument. It performs by first detecting the harmonic currents that are present in a harmonic-contaminated power system, and subsequently generates and injects corrective mitigation current back into the power system to cancel out all the detected harmonic currents. This means that other than the ability to generate corrective mitigation current itself, it is actually more important to make sure that the SAPF is able to operate in phase with the operating power system, so that the mitigation current can correctly be injected. Hence, proper synchronization technique needs to be integrated when designing the control algorithms of SAPF. This paper critically discusses and analyzes various types of existing phase synchronization techniques which have been applied to manage operation of SAPF; in terms of features, working principle, implementation and performance. The analysis provided can potentially serve as a guideline and provision of information on selecting the most suitable technique for synchronizing SAPF with the connected power system. MDPI 2019 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/38327/1/38327.pdf Hoon, Yap and Mohd Radzi, Mohd Amran and Mohd Zainuri, Muhammad Ammirrul Atiqi and Md Zawawi, Mohamad Adzhar (2019) Shunt active power filter: a review on phase synchronization control techniques. Electronics, 8 (7). art. no. 791. pp. 1-20. ISSN 2079-9292 https://www.mdpi.com/2079-9292/8/7/791 10.3390/electronics8070791
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description Owing to the destructive impacts of harmonic currents, the topic of reducing their impacts on power system has attracted tremendous research interests. In this regard, a shunt active power filter (SAPF) is recognized to be the most reliable instrument. It performs by first detecting the harmonic currents that are present in a harmonic-contaminated power system, and subsequently generates and injects corrective mitigation current back into the power system to cancel out all the detected harmonic currents. This means that other than the ability to generate corrective mitigation current itself, it is actually more important to make sure that the SAPF is able to operate in phase with the operating power system, so that the mitigation current can correctly be injected. Hence, proper synchronization technique needs to be integrated when designing the control algorithms of SAPF. This paper critically discusses and analyzes various types of existing phase synchronization techniques which have been applied to manage operation of SAPF; in terms of features, working principle, implementation and performance. The analysis provided can potentially serve as a guideline and provision of information on selecting the most suitable technique for synchronizing SAPF with the connected power system.
format Article
author Hoon, Yap
Mohd Radzi, Mohd Amran
Mohd Zainuri, Muhammad Ammirrul Atiqi
Md Zawawi, Mohamad Adzhar
spellingShingle Hoon, Yap
Mohd Radzi, Mohd Amran
Mohd Zainuri, Muhammad Ammirrul Atiqi
Md Zawawi, Mohamad Adzhar
Shunt active power filter: a review on phase synchronization control techniques
author_facet Hoon, Yap
Mohd Radzi, Mohd Amran
Mohd Zainuri, Muhammad Ammirrul Atiqi
Md Zawawi, Mohamad Adzhar
author_sort Hoon, Yap
title Shunt active power filter: a review on phase synchronization control techniques
title_short Shunt active power filter: a review on phase synchronization control techniques
title_full Shunt active power filter: a review on phase synchronization control techniques
title_fullStr Shunt active power filter: a review on phase synchronization control techniques
title_full_unstemmed Shunt active power filter: a review on phase synchronization control techniques
title_sort shunt active power filter: a review on phase synchronization control techniques
publisher MDPI
publishDate 2019
url http://psasir.upm.edu.my/id/eprint/38327/1/38327.pdf
http://psasir.upm.edu.my/id/eprint/38327/
https://www.mdpi.com/2079-9292/8/7/791
_version_ 1665895975618609152
score 13.211869