Strength Estimation of Concrete in Different Environments Using UPV
Deterioration of concrete in a structure is a result of several internal and external degradation mechanisms which decrease the strength or the integrity of the structure. This paper presents results of use of non-destructive ultrasonic pulse velocity tests (UPV) to determine the strength of concret...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English English |
Published: |
Universiti Putra Malaysia Press
2002
|
Online Access: | http://psasir.upm.edu.my/id/eprint/3780/1/Strength_Estimation_of_Concrete_in_Different.pdf http://psasir.upm.edu.my/id/eprint/3780/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.upm.eprints.3780 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.37802013-05-27T07:11:10Z http://psasir.upm.edu.my/id/eprint/3780/ Strength Estimation of Concrete in Different Environments Using UPV Jaafar, Mohd Saleh Thanoon, Waleed Abdulmalik Mohiuddin Khan, Shibli Russel Trikha, D. N. Deterioration of concrete in a structure is a result of several internal and external degradation mechanisms which decrease the strength or the integrity of the structure. This paper presents results of use of non-destructive ultrasonic pulse velocity tests (UPV) to determine the strength of concrete in three different environments, namely oven-dry, air-dry and saturated conditions, as the full potential of UPV in different environments is still not fully explored. Moisture is known to have a significant effect on ultrasonic pulse velocity. In order to improve the efficiency of UPV in estimating the concrete strength, the degree of moisture present in the concrete i.e. the physical condition of the concrete is to be considered. Pulse velocity path in the different physical conditions of concrete also has to be examined. In the present investigations, four different grades of concrete in three different environments were considered. Extensive series of tests were carried out in the laboratory to obtain a correlation of the UPV test results with the actual compressive strength of concrete. A total of 108 cubes were cast. The cement used was the ordinary Portland cement and the coarse aggregate consisted of granite with the maximum aggregate size of 19mm as is generally used in conventional RC structures. The DOE-method of mix-design was used to design four different grades of concrete in order to simulate concrete strengths found in practice. Test results indicated that the presence of moisture in concrete changes the UPV values significantly. The UPV tests through the direct transmission measurements display better estimates compared to the indirect measurements. Exponential expressions have been proposed for the strength estimation of concrete under oven dry and air dry conditions. Universiti Putra Malaysia Press 2002 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/3780/1/Strength_Estimation_of_Concrete_in_Different.pdf Jaafar, Mohd Saleh and Thanoon, Waleed Abdulmalik and Mohiuddin Khan, Shibli Russel and Trikha, D. N. (2002) Strength Estimation of Concrete in Different Environments Using UPV. Pertanika Journal of Science & Technology, 10 (2). pp. 179-186. ISSN 0128-7680 English |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English English |
description |
Deterioration of concrete in a structure is a result of several internal and external degradation mechanisms which decrease the strength or the integrity of the structure. This paper presents results of use of non-destructive ultrasonic pulse velocity tests (UPV) to determine the strength of concrete in three different environments, namely oven-dry, air-dry and saturated conditions, as
the full potential of UPV in different environments is still not fully explored. Moisture is known to have a significant effect on ultrasonic pulse velocity. In
order to improve the efficiency of UPV in estimating the concrete strength, the
degree of moisture present in the concrete i.e. the physical condition of the
concrete is to be considered. Pulse velocity path in the different physical conditions of concrete also has to be examined. In the present investigations, four different grades of concrete in three different environments were
considered. Extensive series of tests were carried out in the laboratory to obtain
a correlation of the UPV test results with the actual compressive strength of
concrete. A total of 108 cubes were cast. The cement used was the ordinary Portland cement and the coarse aggregate consisted of granite with the
maximum aggregate size of 19mm as is generally used in conventional RC
structures. The DOE-method of mix-design was used to design four different
grades of concrete in order to simulate concrete strengths found in practice.
Test results indicated that the presence of moisture in concrete changes the
UPV values significantly. The UPV tests through the direct transmission
measurements display better estimates compared to the indirect measurements.
Exponential expressions have been proposed for the strength estimation of
concrete under oven dry and air dry conditions. |
format |
Article |
author |
Jaafar, Mohd Saleh Thanoon, Waleed Abdulmalik Mohiuddin Khan, Shibli Russel Trikha, D. N. |
spellingShingle |
Jaafar, Mohd Saleh Thanoon, Waleed Abdulmalik Mohiuddin Khan, Shibli Russel Trikha, D. N. Strength Estimation of Concrete in Different Environments Using UPV |
author_facet |
Jaafar, Mohd Saleh Thanoon, Waleed Abdulmalik Mohiuddin Khan, Shibli Russel Trikha, D. N. |
author_sort |
Jaafar, Mohd Saleh |
title |
Strength Estimation of Concrete in Different
Environments Using UPV |
title_short |
Strength Estimation of Concrete in Different
Environments Using UPV |
title_full |
Strength Estimation of Concrete in Different
Environments Using UPV |
title_fullStr |
Strength Estimation of Concrete in Different
Environments Using UPV |
title_full_unstemmed |
Strength Estimation of Concrete in Different
Environments Using UPV |
title_sort |
strength estimation of concrete in different
environments using upv |
publisher |
Universiti Putra Malaysia Press |
publishDate |
2002 |
url |
http://psasir.upm.edu.my/id/eprint/3780/1/Strength_Estimation_of_Concrete_in_Different.pdf http://psasir.upm.edu.my/id/eprint/3780/ |
_version_ |
1643822710938140672 |
score |
13.211869 |