A hybrid method for endocardial contour extraction of right ventricle in 4-slices from 3D echocardiography dataset

This paper presents a hybrid method to extract endocardial contour of the right ventricular (RV) in 4-slices from 3D echocardiography dataset. The overall framework comprises four processing phases. In Phase I, the region of interest (ROI) is identified by estimating the cavity boundary. Speckle noi...

Full description

Saved in:
Bibliographic Details
Main Authors: Dawood, Faten Abed Ali, O. K. Rahmat, Rahmita Wirza, Kadiman, Suhaini, Abdullah, Lili Nurliyana, Dimon, Mohd Zamrin
Format: Article
Language:English
Published: Hindawi Publishing Corporation 2014
Online Access:http://psasir.upm.edu.my/id/eprint/36172/1/36172.pdf
http://psasir.upm.edu.my/id/eprint/36172/
https://www.hindawi.com/journals/abi/2014/207149/abs/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.36172
record_format eprints
spelling my.upm.eprints.361722017-10-30T03:17:30Z http://psasir.upm.edu.my/id/eprint/36172/ A hybrid method for endocardial contour extraction of right ventricle in 4-slices from 3D echocardiography dataset Dawood, Faten Abed Ali O. K. Rahmat, Rahmita Wirza Kadiman, Suhaini Abdullah, Lili Nurliyana Dimon, Mohd Zamrin This paper presents a hybrid method to extract endocardial contour of the right ventricular (RV) in 4-slices from 3D echocardiography dataset. The overall framework comprises four processing phases. In Phase I, the region of interest (ROI) is identified by estimating the cavity boundary. Speckle noise reduction and contrast enhancement were implemented in Phase II as preprocessing tasks. In Phase III, the RV cavity region was segmented by generating intensity threshold which was used for once for all frames. Finally, Phase IV is proposed to extract the RV endocardial contour in a complete cardiac cycle using a combination of shape-based contour detection and improved radial search algorithm. The proposed method was applied to 16 datasets of 3D echocardiography encompassing the RV in long-axis view. The accuracy of experimental results obtained by the proposed method was evaluated qualitatively and quantitatively. It has been done by comparing the segmentation results of RV cavity based on endocardial contour extraction with the ground truth. The comparative analysis results show that the proposed method performs efficiently in all datasets with overall performance of 95% and the root mean square distances (RMSD) measure in terms of mean ± SD was found to be 2.21 ± 0.35 mm for RV endocardial contours. Hindawi Publishing Corporation 2014 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/36172/1/36172.pdf Dawood, Faten Abed Ali and O. K. Rahmat, Rahmita Wirza and Kadiman, Suhaini and Abdullah, Lili Nurliyana and Dimon, Mohd Zamrin (2014) A hybrid method for endocardial contour extraction of right ventricle in 4-slices from 3D echocardiography dataset. Advances in Bioinformatics, 2014. art. no. 207149. pp. 1-15. ISSN 1687-8027; ESSN: 1687-8035 https://www.hindawi.com/journals/abi/2014/207149/abs/ 10.1155/2014/207149
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description This paper presents a hybrid method to extract endocardial contour of the right ventricular (RV) in 4-slices from 3D echocardiography dataset. The overall framework comprises four processing phases. In Phase I, the region of interest (ROI) is identified by estimating the cavity boundary. Speckle noise reduction and contrast enhancement were implemented in Phase II as preprocessing tasks. In Phase III, the RV cavity region was segmented by generating intensity threshold which was used for once for all frames. Finally, Phase IV is proposed to extract the RV endocardial contour in a complete cardiac cycle using a combination of shape-based contour detection and improved radial search algorithm. The proposed method was applied to 16 datasets of 3D echocardiography encompassing the RV in long-axis view. The accuracy of experimental results obtained by the proposed method was evaluated qualitatively and quantitatively. It has been done by comparing the segmentation results of RV cavity based on endocardial contour extraction with the ground truth. The comparative analysis results show that the proposed method performs efficiently in all datasets with overall performance of 95% and the root mean square distances (RMSD) measure in terms of mean ± SD was found to be 2.21 ± 0.35 mm for RV endocardial contours.
format Article
author Dawood, Faten Abed Ali
O. K. Rahmat, Rahmita Wirza
Kadiman, Suhaini
Abdullah, Lili Nurliyana
Dimon, Mohd Zamrin
spellingShingle Dawood, Faten Abed Ali
O. K. Rahmat, Rahmita Wirza
Kadiman, Suhaini
Abdullah, Lili Nurliyana
Dimon, Mohd Zamrin
A hybrid method for endocardial contour extraction of right ventricle in 4-slices from 3D echocardiography dataset
author_facet Dawood, Faten Abed Ali
O. K. Rahmat, Rahmita Wirza
Kadiman, Suhaini
Abdullah, Lili Nurliyana
Dimon, Mohd Zamrin
author_sort Dawood, Faten Abed Ali
title A hybrid method for endocardial contour extraction of right ventricle in 4-slices from 3D echocardiography dataset
title_short A hybrid method for endocardial contour extraction of right ventricle in 4-slices from 3D echocardiography dataset
title_full A hybrid method for endocardial contour extraction of right ventricle in 4-slices from 3D echocardiography dataset
title_fullStr A hybrid method for endocardial contour extraction of right ventricle in 4-slices from 3D echocardiography dataset
title_full_unstemmed A hybrid method for endocardial contour extraction of right ventricle in 4-slices from 3D echocardiography dataset
title_sort hybrid method for endocardial contour extraction of right ventricle in 4-slices from 3d echocardiography dataset
publisher Hindawi Publishing Corporation
publishDate 2014
url http://psasir.upm.edu.my/id/eprint/36172/1/36172.pdf
http://psasir.upm.edu.my/id/eprint/36172/
https://www.hindawi.com/journals/abi/2014/207149/abs/
_version_ 1643831669905424384
score 13.160551