A comparative study of three types of grid connected photovoltaic systems based on actual performance
In this study, three photovoltaic (PV) systems are evaluated based on actual performance. The energy generation of three types of PV systems namely concentrating PV system (6 units × 1 kWp), PV system with sun tracking flat (2 units × 1 kWp) and fixed flat PV system (2 units × 1 kWp) is analyzed in...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2014
|
Online Access: | http://psasir.upm.edu.my/id/eprint/36138/1/A%20comparative%20study%20of%20three%20types%20of%20grid%20connected%20photovoltaic%20systems%20based%20on%20actual%20performance.pdf http://psasir.upm.edu.my/id/eprint/36138/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.upm.eprints.36138 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.361382015-10-23T02:16:22Z http://psasir.upm.edu.my/id/eprint/36138/ A comparative study of three types of grid connected photovoltaic systems based on actual performance Ya’acob, Mohd Effendy Hizam, Hashim Khatib, Tamer Mohd Radzi, Mohd Amran In this study, three photovoltaic (PV) systems are evaluated based on actual performance. The energy generation of three types of PV systems namely concentrating PV system (6 units × 1 kWp), PV system with sun tracking flat (2 units × 1 kWp) and fixed flat PV system (2 units × 1 kWp) is analyzed in this research. Data analysis for ten consecutive months consisting of 12,190 samples of 15 min interval is done. The performance evaluation is done using energy yield, yield factor, capacity factor, power efficiency and PV array efficiency. Based on the experiment data, it is concluded that tracking flat PV system is the most suitable system for Malaysia in normal operation mode with average daily generation of 4.7 kW h (141 kW h as a monthly average), system efficiency of 11%, power efficiency of 85%, average daily yield factor of 2.3 kW h/kWp and capacity factor of 32%. This study also highlights the PV energy (EPV) models for each PV generators with respect to the environmental factors. The advantage of employing a tracking flat system as compared to the fixed flat system is considered based on the effectiveness of the dual-axis tracking mechanism tracking the sun for maximum power output. Elsevier 2014-02 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/36138/1/A%20comparative%20study%20of%20three%20types%20of%20grid%20connected%20photovoltaic%20systems%20based%20on%20actual%20performance.pdf Ya’acob, Mohd Effendy and Hizam, Hashim and Khatib, Tamer and Mohd Radzi, Mohd Amran (2014) A comparative study of three types of grid connected photovoltaic systems based on actual performance. Energy Conversion and Management, 78. pp. 8-13. ISSN 0196-8904; ESSN: 1879-2227 10.1016/j.enconman.2013.10.064 |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English |
description |
In this study, three photovoltaic (PV) systems are evaluated based on actual performance. The energy generation of three types of PV systems namely concentrating PV system (6 units × 1 kWp), PV system with sun tracking flat (2 units × 1 kWp) and fixed flat PV system (2 units × 1 kWp) is analyzed in this research. Data analysis for ten consecutive months consisting of 12,190 samples of 15 min interval is done. The performance evaluation is done using energy yield, yield factor, capacity factor, power efficiency and PV array efficiency. Based on the experiment data, it is concluded that tracking flat PV system is the most suitable system for Malaysia in normal operation mode with average daily generation of 4.7 kW h (141 kW h as a monthly average), system efficiency of 11%, power efficiency of 85%, average daily yield factor of 2.3 kW h/kWp and capacity factor of 32%. This study also highlights the PV energy (EPV) models for each PV generators with respect to the environmental factors. The advantage of employing a tracking flat system as compared to the fixed flat system is considered based on the effectiveness of the dual-axis tracking mechanism tracking the sun for maximum power output. |
format |
Article |
author |
Ya’acob, Mohd Effendy Hizam, Hashim Khatib, Tamer Mohd Radzi, Mohd Amran |
spellingShingle |
Ya’acob, Mohd Effendy Hizam, Hashim Khatib, Tamer Mohd Radzi, Mohd Amran A comparative study of three types of grid connected photovoltaic systems based on actual performance |
author_facet |
Ya’acob, Mohd Effendy Hizam, Hashim Khatib, Tamer Mohd Radzi, Mohd Amran |
author_sort |
Ya’acob, Mohd Effendy |
title |
A comparative study of three types of grid connected photovoltaic systems based on actual performance |
title_short |
A comparative study of three types of grid connected photovoltaic systems based on actual performance |
title_full |
A comparative study of three types of grid connected photovoltaic systems based on actual performance |
title_fullStr |
A comparative study of three types of grid connected photovoltaic systems based on actual performance |
title_full_unstemmed |
A comparative study of three types of grid connected photovoltaic systems based on actual performance |
title_sort |
comparative study of three types of grid connected photovoltaic systems based on actual performance |
publisher |
Elsevier |
publishDate |
2014 |
url |
http://psasir.upm.edu.my/id/eprint/36138/1/A%20comparative%20study%20of%20three%20types%20of%20grid%20connected%20photovoltaic%20systems%20based%20on%20actual%20performance.pdf http://psasir.upm.edu.my/id/eprint/36138/ |
_version_ |
1643831660231262208 |
score |
13.211869 |