Validation of flow impact to detect the energy loss in ball valve
Researchers especially from engineering field are using Computer Fluid Dynamic (CFD) software to simulate the three dimension (3D) model before they perform any experiments to prove their theories. The aim of this study is to develop a valve model in 3D using Solidworks software and to analyze inter...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Trans Tech Publications
2014
|
Online Access: | http://psasir.upm.edu.my/id/eprint/35960/1/Validation%20of%20flow%20impact%20to%20detect%20the%20energy%20loss%20in%20ball%20valve.pdf http://psasir.upm.edu.my/id/eprint/35960/ https://www.scientific.net/AMM.564.281 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.upm.eprints.35960 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.359602021-12-01T04:04:13Z http://psasir.upm.edu.my/id/eprint/35960/ Validation of flow impact to detect the energy loss in ball valve Yusof, N. S. B. Mohd Rafie, Azmin Shakrine Mohd Ariffin, Mohd. Khairol Anuar Othman, Norzila Researchers especially from engineering field are using Computer Fluid Dynamic (CFD) software to simulate the three dimension (3D) model before they perform any experiments to prove their theories. The aim of this study is to develop a valve model in 3D using Solidworks software and to analyze internal fluid flow using Solidworks Flow Simulation (SWF) software to prove that this software has the capability in performing fluid simulations for the ball valve. The SWF successfully calculates the value of outlet velocity for the ball valve at different closing angles and different pressures value. The results shown are significantly acceptable by referring to the outputs of practical experiment and simulation incidence’s error of Ozdamar model 2007. The average error in calculation for SWF is about 7.42%, unlike FLUENT which is around 11.09%. Therefore; the engineers can simulate their models with higher accuracy using SWF software. Trans Tech Publications 2014 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/35960/1/Validation%20of%20flow%20impact%20to%20detect%20the%20energy%20loss%20in%20ball%20valve.pdf Yusof, N. S. B. and Mohd Rafie, Azmin Shakrine and Mohd Ariffin, Mohd. Khairol Anuar and Othman, Norzila (2014) Validation of flow impact to detect the energy loss in ball valve. Applied Mechanics and Materials, 564. pp. 281-286. ISSN 1660-9336; ESSN: 1662-7482 https://www.scientific.net/AMM.564.281 10.4028/www.scientific.net/AMM.564.281 |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English |
description |
Researchers especially from engineering field are using Computer Fluid Dynamic (CFD) software to simulate the three dimension (3D) model before they perform any experiments to prove their theories. The aim of this study is to develop a valve model in 3D using Solidworks software and to analyze internal fluid flow using Solidworks Flow Simulation (SWF) software to prove that this software has the capability in performing fluid simulations for the ball valve. The SWF successfully calculates the value of outlet velocity for the ball valve at different closing angles and different pressures value. The results shown are significantly acceptable by referring to the outputs of practical experiment and simulation incidence’s error of Ozdamar model 2007. The average error in calculation for SWF is about 7.42%, unlike FLUENT which is around 11.09%. Therefore; the engineers can simulate their models with higher accuracy using SWF software. |
format |
Article |
author |
Yusof, N. S. B. Mohd Rafie, Azmin Shakrine Mohd Ariffin, Mohd. Khairol Anuar Othman, Norzila |
spellingShingle |
Yusof, N. S. B. Mohd Rafie, Azmin Shakrine Mohd Ariffin, Mohd. Khairol Anuar Othman, Norzila Validation of flow impact to detect the energy loss in ball valve |
author_facet |
Yusof, N. S. B. Mohd Rafie, Azmin Shakrine Mohd Ariffin, Mohd. Khairol Anuar Othman, Norzila |
author_sort |
Yusof, N. S. B. |
title |
Validation of flow impact to detect the energy loss in ball valve |
title_short |
Validation of flow impact to detect the energy loss in ball valve |
title_full |
Validation of flow impact to detect the energy loss in ball valve |
title_fullStr |
Validation of flow impact to detect the energy loss in ball valve |
title_full_unstemmed |
Validation of flow impact to detect the energy loss in ball valve |
title_sort |
validation of flow impact to detect the energy loss in ball valve |
publisher |
Trans Tech Publications |
publishDate |
2014 |
url |
http://psasir.upm.edu.my/id/eprint/35960/1/Validation%20of%20flow%20impact%20to%20detect%20the%20energy%20loss%20in%20ball%20valve.pdf http://psasir.upm.edu.my/id/eprint/35960/ https://www.scientific.net/AMM.564.281 |
_version_ |
1718927692579995648 |
score |
13.214268 |