Improving performance of automated coronary arterial tree center-line extraction, stent localization and tracking

Stent placement is a common procedure in Percutaneous Transluminal Coronary Angioplasty which helps many patients to avoid emergency heart bypass surgery or heart attack. In this procedure, a stent is implanted at the narrowing part of an artery to keep its lumen open allowing blood to flow normally...

Full description

Saved in:
Bibliographic Details
Main Author: Boroujeni, Farsad Zamani
Format: Thesis
Language:English
Published: 2012
Online Access:http://psasir.upm.edu.my/id/eprint/31411/1/FSKTM%202012%2028R.pdf
http://psasir.upm.edu.my/id/eprint/31411/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.31411
record_format eprints
spelling my.upm.eprints.314112015-02-12T01:07:53Z http://psasir.upm.edu.my/id/eprint/31411/ Improving performance of automated coronary arterial tree center-line extraction, stent localization and tracking Boroujeni, Farsad Zamani Stent placement is a common procedure in Percutaneous Transluminal Coronary Angioplasty which helps many patients to avoid emergency heart bypass surgery or heart attack. In this procedure, a stent is implanted at the narrowing part of an artery to keep its lumen open allowing blood to flow normally through the artery. A potential risk of this treatment is the inaccurate placement of the stent (geographic miss), which could result in serious complications for the patient such as development of new stenotic lesions, increasing the likelihood of blood clot formation and the need for revascularization. Over the last decade, many algorithms have been developed to address this problem. However, most of them either fail to meet the demanding requirements of real-time assistant systems or to provide quantitative analysis for erification of stent placement task. In this research work, we report on new contributions to the major parts of a computer assisted stent positioning system. The first contribution is automatic detection of seed points which serve as a prerequisite step for centerline extraction algorithm. The solution consists of an algorithm for automatic collection of candidate seed points using efficient grid line searching mechanism and a validation method which uses local geometric and intensity based features as effective validation rules to discriminate between the actual seed point and false alarms. The experimental results show that combining the advantages of the geometric based validation and contrast based filtering as well as avoiding large quantization errors, lead to significant enhancement in the performance of the seed point detection algorithm in terms of balancing between the precision and recall. The second contribution is related to the robust and accurate extraction of centerlines for all vessel segments of the arterial tree in the angiogram images. This problem is addressed by proposing an accurate and robust centerline extraction method. Starting at each detected seed point, the centerline extraction method utilizes eigenvalues and eigenvectors of Hessian matrix for the pixels located on a semi-circular scanning profile for robust estimation of the next centerline point. The experimental validations show that the use of Hessian matrix results in significant improvement in the robustness of the tracing algorithm. The stent localization and tracking in angiogram image sequence is the topic of the third contribution. The proposed method combines special fast filtering, region of interest processing and graph based trajectory analysis approach to localize and track the radioopaque markers of the stent in fluoroscopic frame sequences. The most interesting finding was that the validation of the potential markers prior to building tracks of marker pairs, causes the landmark detection process to avoid dealing with a large number of outliers and misdetections. In total, the current study found that the proposed algorithms outperform their well-established existing counterparts indicating their suitability to be adopted in practical computer assisted stent positioning systems. 2012-12 Thesis NonPeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/31411/1/FSKTM%202012%2028R.pdf Boroujeni, Farsad Zamani (2012) Improving performance of automated coronary arterial tree center-line extraction, stent localization and tracking. PhD thesis, Universiti Putra Malaysia.
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description Stent placement is a common procedure in Percutaneous Transluminal Coronary Angioplasty which helps many patients to avoid emergency heart bypass surgery or heart attack. In this procedure, a stent is implanted at the narrowing part of an artery to keep its lumen open allowing blood to flow normally through the artery. A potential risk of this treatment is the inaccurate placement of the stent (geographic miss), which could result in serious complications for the patient such as development of new stenotic lesions, increasing the likelihood of blood clot formation and the need for revascularization. Over the last decade, many algorithms have been developed to address this problem. However, most of them either fail to meet the demanding requirements of real-time assistant systems or to provide quantitative analysis for erification of stent placement task. In this research work, we report on new contributions to the major parts of a computer assisted stent positioning system. The first contribution is automatic detection of seed points which serve as a prerequisite step for centerline extraction algorithm. The solution consists of an algorithm for automatic collection of candidate seed points using efficient grid line searching mechanism and a validation method which uses local geometric and intensity based features as effective validation rules to discriminate between the actual seed point and false alarms. The experimental results show that combining the advantages of the geometric based validation and contrast based filtering as well as avoiding large quantization errors, lead to significant enhancement in the performance of the seed point detection algorithm in terms of balancing between the precision and recall. The second contribution is related to the robust and accurate extraction of centerlines for all vessel segments of the arterial tree in the angiogram images. This problem is addressed by proposing an accurate and robust centerline extraction method. Starting at each detected seed point, the centerline extraction method utilizes eigenvalues and eigenvectors of Hessian matrix for the pixels located on a semi-circular scanning profile for robust estimation of the next centerline point. The experimental validations show that the use of Hessian matrix results in significant improvement in the robustness of the tracing algorithm. The stent localization and tracking in angiogram image sequence is the topic of the third contribution. The proposed method combines special fast filtering, region of interest processing and graph based trajectory analysis approach to localize and track the radioopaque markers of the stent in fluoroscopic frame sequences. The most interesting finding was that the validation of the potential markers prior to building tracks of marker pairs, causes the landmark detection process to avoid dealing with a large number of outliers and misdetections. In total, the current study found that the proposed algorithms outperform their well-established existing counterparts indicating their suitability to be adopted in practical computer assisted stent positioning systems.
format Thesis
author Boroujeni, Farsad Zamani
spellingShingle Boroujeni, Farsad Zamani
Improving performance of automated coronary arterial tree center-line extraction, stent localization and tracking
author_facet Boroujeni, Farsad Zamani
author_sort Boroujeni, Farsad Zamani
title Improving performance of automated coronary arterial tree center-line extraction, stent localization and tracking
title_short Improving performance of automated coronary arterial tree center-line extraction, stent localization and tracking
title_full Improving performance of automated coronary arterial tree center-line extraction, stent localization and tracking
title_fullStr Improving performance of automated coronary arterial tree center-line extraction, stent localization and tracking
title_full_unstemmed Improving performance of automated coronary arterial tree center-line extraction, stent localization and tracking
title_sort improving performance of automated coronary arterial tree center-line extraction, stent localization and tracking
publishDate 2012
url http://psasir.upm.edu.my/id/eprint/31411/1/FSKTM%202012%2028R.pdf
http://psasir.upm.edu.my/id/eprint/31411/
_version_ 1643830318608678912
score 13.214268