Heat transfer to laminar flow over a double backward-facing step

Heat transfer and laminar air flow over a double backward-facing step numerically studied in this paper. The simulations was performed by using ANSYS ICEM for meshing process and using ANSYS fluent 14 (CFD) for solving. The k-ɛ standard model adopted with Reynolds number varied between 98.5 to 512 a...

Full description

Saved in:
Bibliographic Details
Main Authors: Togun, Hussein, Abdulrazzaq, Tuqa, Kazi, Md. Salim Newaz, Badarudin, A., Mohd Ariffin, Mohd Khairol Anuar
Format: Article
Language:English
Published: World Academy of Science, Engineering and Technology 2013
Online Access:http://psasir.upm.edu.my/id/eprint/28712/1/Heat%20transfer%20to%20laminar%20flow%20over%20a%20double%20backward.pdf
http://psasir.upm.edu.my/id/eprint/28712/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.28712
record_format eprints
spelling my.upm.eprints.287122015-12-29T04:13:28Z http://psasir.upm.edu.my/id/eprint/28712/ Heat transfer to laminar flow over a double backward-facing step Togun, Hussein Abdulrazzaq, Tuqa Kazi, Md. Salim Newaz Badarudin, A. Mohd Ariffin, Mohd Khairol Anuar Heat transfer and laminar air flow over a double backward-facing step numerically studied in this paper. The simulations was performed by using ANSYS ICEM for meshing process and using ANSYS fluent 14 (CFD) for solving. The k-ɛ standard model adopted with Reynolds number varied between 98.5 to 512 and three step height at constant heat flux (q=2000 W/m2). The top of wall and bottom of upstream are insulated with bottom of downstream is heated. The results show increase in Nusselt number with increases of Reynolds number for all cases and the maximum of Nusselt number happens at the first step in compared to the second step. Due to increase of cross section area of downstream to generate sudden expansion then Nusselt number decrease but the profile of Nusselt number keep same trend for all cases where increase after the first and second steps. Recirculation region after the first and second steps are denoted by contour of streamline velocity. The higher augmentation of heat transfer rate observed for case 1 at Reynolds number of 512 and heat flux q=2000 W/m2. World Academy of Science, Engineering and Technology 2013 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/28712/1/Heat%20transfer%20to%20laminar%20flow%20over%20a%20double%20backward.pdf Togun, Hussein and Abdulrazzaq, Tuqa and Kazi, Md. Salim Newaz and Badarudin, A. and Mohd Ariffin, Mohd Khairol Anuar (2013) Heat transfer to laminar flow over a double backward-facing step. International Journal of Mechanical, Aerospace, Industrial and Mechatronics Engineer, 7 (8). pp. 667-672. ISSN 2010-376X
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description Heat transfer and laminar air flow over a double backward-facing step numerically studied in this paper. The simulations was performed by using ANSYS ICEM for meshing process and using ANSYS fluent 14 (CFD) for solving. The k-ɛ standard model adopted with Reynolds number varied between 98.5 to 512 and three step height at constant heat flux (q=2000 W/m2). The top of wall and bottom of upstream are insulated with bottom of downstream is heated. The results show increase in Nusselt number with increases of Reynolds number for all cases and the maximum of Nusselt number happens at the first step in compared to the second step. Due to increase of cross section area of downstream to generate sudden expansion then Nusselt number decrease but the profile of Nusselt number keep same trend for all cases where increase after the first and second steps. Recirculation region after the first and second steps are denoted by contour of streamline velocity. The higher augmentation of heat transfer rate observed for case 1 at Reynolds number of 512 and heat flux q=2000 W/m2.
format Article
author Togun, Hussein
Abdulrazzaq, Tuqa
Kazi, Md. Salim Newaz
Badarudin, A.
Mohd Ariffin, Mohd Khairol Anuar
spellingShingle Togun, Hussein
Abdulrazzaq, Tuqa
Kazi, Md. Salim Newaz
Badarudin, A.
Mohd Ariffin, Mohd Khairol Anuar
Heat transfer to laminar flow over a double backward-facing step
author_facet Togun, Hussein
Abdulrazzaq, Tuqa
Kazi, Md. Salim Newaz
Badarudin, A.
Mohd Ariffin, Mohd Khairol Anuar
author_sort Togun, Hussein
title Heat transfer to laminar flow over a double backward-facing step
title_short Heat transfer to laminar flow over a double backward-facing step
title_full Heat transfer to laminar flow over a double backward-facing step
title_fullStr Heat transfer to laminar flow over a double backward-facing step
title_full_unstemmed Heat transfer to laminar flow over a double backward-facing step
title_sort heat transfer to laminar flow over a double backward-facing step
publisher World Academy of Science, Engineering and Technology
publishDate 2013
url http://psasir.upm.edu.my/id/eprint/28712/1/Heat%20transfer%20to%20laminar%20flow%20over%20a%20double%20backward.pdf
http://psasir.upm.edu.my/id/eprint/28712/
_version_ 1643829546129031168
score 13.160551