Low Cost front-end readout electronic for instrumentation used in Neutron experiments.

In the field of material characterization, the neutron scattering technique is found to be useful in so many applications. This technique requires a position sensitive neutron detector (PSND) and their front-end readouts (FER) electronic to detect the position of neutron interactions. Normally, the...

Full description

Saved in:
Bibliographic Details
Main Authors: Lombigit, Lojius, Hamidon, Mohd Nizar, Khalid, Mohd Ashhar, Sulaiman, Nasri
Format: Article
Language:English
English
Published: 2012
Online Access:http://psasir.upm.edu.my/id/eprint/23484/1/Low%20Cost%20front.pdf
http://psasir.upm.edu.my/id/eprint/23484/
http://www.academicjournals.org/journal/IJPS/edition/23_MAY
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.23484
record_format eprints
spelling my.upm.eprints.234842015-10-02T03:07:59Z http://psasir.upm.edu.my/id/eprint/23484/ Low Cost front-end readout electronic for instrumentation used in Neutron experiments. Lombigit, Lojius Hamidon, Mohd Nizar Khalid, Mohd Ashhar Sulaiman, Nasri In the field of material characterization, the neutron scattering technique is found to be useful in so many applications. This technique requires a position sensitive neutron detector (PSND) and their front-end readouts (FER) electronic to detect the position of neutron interactions. Normally, the PSND is designed for specific applications and has unique technical specifications. Therefore, it requires a customised electronic FER to match its specifications. Furthermore, a large active area requires a large number of FER electronic and, therefore, there is, also, an increased development cost. This paper presents a simple and low-cost design for FER electronic which consists of an eight channels preamplifier-shaper suitable for instrumentation used in neutron experiments. This FER was built entirely with low-noise FET-input operational amplifier (Op-amp) and passive components. The development cost is around U.S. $50/channel. Results have shown that it is capable of accepting a wide dynamic range input charge (20 to 600 fC) with an excellent output linearity (nonlinearity < 1%). It has a good equivalent noise charge (ENC) with a performance average of 2113 e- and is less sensitive to input capacitance variation (24 e-/pF). 2012 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/23484/1/Low%20Cost%20front.pdf Lombigit, Lojius and Hamidon, Mohd Nizar and Khalid, Mohd Ashhar and Sulaiman, Nasri (2012) Low Cost front-end readout electronic for instrumentation used in Neutron experiments. International Journal of the Physical Sciences, 7 (20). art. no. 141EF9019091. pp. 2812-2817. ISSN 1992-1950 http://www.academicjournals.org/journal/IJPS/edition/23_MAY 10.5897/IJPS12.090 English
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
English
description In the field of material characterization, the neutron scattering technique is found to be useful in so many applications. This technique requires a position sensitive neutron detector (PSND) and their front-end readouts (FER) electronic to detect the position of neutron interactions. Normally, the PSND is designed for specific applications and has unique technical specifications. Therefore, it requires a customised electronic FER to match its specifications. Furthermore, a large active area requires a large number of FER electronic and, therefore, there is, also, an increased development cost. This paper presents a simple and low-cost design for FER electronic which consists of an eight channels preamplifier-shaper suitable for instrumentation used in neutron experiments. This FER was built entirely with low-noise FET-input operational amplifier (Op-amp) and passive components. The development cost is around U.S. $50/channel. Results have shown that it is capable of accepting a wide dynamic range input charge (20 to 600 fC) with an excellent output linearity (nonlinearity < 1%). It has a good equivalent noise charge (ENC) with a performance average of 2113 e- and is less sensitive to input capacitance variation (24 e-/pF).
format Article
author Lombigit, Lojius
Hamidon, Mohd Nizar
Khalid, Mohd Ashhar
Sulaiman, Nasri
spellingShingle Lombigit, Lojius
Hamidon, Mohd Nizar
Khalid, Mohd Ashhar
Sulaiman, Nasri
Low Cost front-end readout electronic for instrumentation used in Neutron experiments.
author_facet Lombigit, Lojius
Hamidon, Mohd Nizar
Khalid, Mohd Ashhar
Sulaiman, Nasri
author_sort Lombigit, Lojius
title Low Cost front-end readout electronic for instrumentation used in Neutron experiments.
title_short Low Cost front-end readout electronic for instrumentation used in Neutron experiments.
title_full Low Cost front-end readout electronic for instrumentation used in Neutron experiments.
title_fullStr Low Cost front-end readout electronic for instrumentation used in Neutron experiments.
title_full_unstemmed Low Cost front-end readout electronic for instrumentation used in Neutron experiments.
title_sort low cost front-end readout electronic for instrumentation used in neutron experiments.
publishDate 2012
url http://psasir.upm.edu.my/id/eprint/23484/1/Low%20Cost%20front.pdf
http://psasir.upm.edu.my/id/eprint/23484/
http://www.academicjournals.org/journal/IJPS/edition/23_MAY
_version_ 1643828072381677568
score 13.160551