Transient stability emergency control using generator tripping based on tracking area-based rotor angle combined with UFLS.

This paper concerns with transient stability control which is part of transient stability assessment which needs to be considered so that the power systems remained intact when failures originating from faults occurred in power systems. Conventional under frequency load shedding (UFLS) system is des...

Full description

Saved in:
Bibliographic Details
Main Authors: Abdul Wahab, Noor Izzri, Mohamed, Azah
Format: Article
Language:English
English
Published: Federico II University 2010
Online Access:http://psasir.upm.edu.my/id/eprint/17476/1/Transient%20stability%20emergency%20control%20using%20generator%20tripping%20based%20on%20tracking%20area.pdf
http://psasir.upm.edu.my/id/eprint/17476/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.17476
record_format eprints
spelling my.upm.eprints.174762015-11-05T08:49:18Z http://psasir.upm.edu.my/id/eprint/17476/ Transient stability emergency control using generator tripping based on tracking area-based rotor angle combined with UFLS. Abdul Wahab, Noor Izzri Mohamed, Azah This paper concerns with transient stability control which is part of transient stability assessment which needs to be considered so that the power systems remained intact when failures originating from faults occurred in power systems. Conventional under frequency load shedding (UFLS) system is designed to retrieve the balance of generation and consumption following disturbances occurrences in the system. In UFLS method, whenever the system's frequency drops below a predetermined value, the system loads are shed in stages. An efficient UFLS method needs to be devised so as to reduce the impacts of transient disturbance on power systems and prevent total system blackout. In this paper, an emergency control scheme known as the combined UFLS and generator tripping is developed in order to stabilize the system when unstable faults occurred in a power system. The performance of the combined UFLS and generator tripping scheme is compared with the conventional UFLS control scheme. The results show that the combined control scheme performed better. Federico II University 2010 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/17476/1/Transient%20stability%20emergency%20control%20using%20generator%20tripping%20based%20on%20tracking%20area.pdf Abdul Wahab, Noor Izzri and Mohamed, Azah (2010) Transient stability emergency control using generator tripping based on tracking area-based rotor angle combined with UFLS. International Review of Electrical Engineering, 5 (5). pp. 2317-2326. ISSN 1827-6660 English
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
English
description This paper concerns with transient stability control which is part of transient stability assessment which needs to be considered so that the power systems remained intact when failures originating from faults occurred in power systems. Conventional under frequency load shedding (UFLS) system is designed to retrieve the balance of generation and consumption following disturbances occurrences in the system. In UFLS method, whenever the system's frequency drops below a predetermined value, the system loads are shed in stages. An efficient UFLS method needs to be devised so as to reduce the impacts of transient disturbance on power systems and prevent total system blackout. In this paper, an emergency control scheme known as the combined UFLS and generator tripping is developed in order to stabilize the system when unstable faults occurred in a power system. The performance of the combined UFLS and generator tripping scheme is compared with the conventional UFLS control scheme. The results show that the combined control scheme performed better.
format Article
author Abdul Wahab, Noor Izzri
Mohamed, Azah
spellingShingle Abdul Wahab, Noor Izzri
Mohamed, Azah
Transient stability emergency control using generator tripping based on tracking area-based rotor angle combined with UFLS.
author_facet Abdul Wahab, Noor Izzri
Mohamed, Azah
author_sort Abdul Wahab, Noor Izzri
title Transient stability emergency control using generator tripping based on tracking area-based rotor angle combined with UFLS.
title_short Transient stability emergency control using generator tripping based on tracking area-based rotor angle combined with UFLS.
title_full Transient stability emergency control using generator tripping based on tracking area-based rotor angle combined with UFLS.
title_fullStr Transient stability emergency control using generator tripping based on tracking area-based rotor angle combined with UFLS.
title_full_unstemmed Transient stability emergency control using generator tripping based on tracking area-based rotor angle combined with UFLS.
title_sort transient stability emergency control using generator tripping based on tracking area-based rotor angle combined with ufls.
publisher Federico II University
publishDate 2010
url http://psasir.upm.edu.my/id/eprint/17476/1/Transient%20stability%20emergency%20control%20using%20generator%20tripping%20based%20on%20tracking%20area.pdf
http://psasir.upm.edu.my/id/eprint/17476/
_version_ 1643826529135755264
score 13.18916