Reduction of stimulated Brillouin scattering threshold through pump recycling technique.

We demonstrate a simple method of stimulated Brillouin scattering (SBS) threshold reduction through a procedure of Brillouin pump recycling technique. High reflectivity optical mirror was incorporated onto our experimental structure in order to recycle the forward transmitted Brillouin pump signal b...

Full description

Saved in:
Bibliographic Details
Main Authors: Ajiya, Mohammed, Mahdi, Mohd Adzir, Al-Mansoori, Mohammed Hayder, Shee, Yu Gang, Hitam, Salasiah, Mokhtar, Makhfudzah
Format: Article
Language:English
Published: Wiley-VCH Verlag 2009
Online Access:http://psasir.upm.edu.my/id/eprint/16465/1/Reduction%20of%20stimulated%20Brillouin%20scattering%20threshold%20through%20pump%20recycling%20technique.pdf
http://psasir.upm.edu.my/id/eprint/16465/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.16465
record_format eprints
spelling my.upm.eprints.164652015-11-26T07:47:46Z http://psasir.upm.edu.my/id/eprint/16465/ Reduction of stimulated Brillouin scattering threshold through pump recycling technique. Ajiya, Mohammed Mahdi, Mohd Adzir Al-Mansoori, Mohammed Hayder Shee, Yu Gang Hitam, Salasiah Mokhtar, Makhfudzah We demonstrate a simple method of stimulated Brillouin scattering (SBS) threshold reduction through a procedure of Brillouin pump recycling technique. High reflectivity optical mirror was incorporated onto our experimental structure in order to recycle the forward transmitted Brillouin pump signal back into the Brillouin gain medium thereby increasing its effective gain. In a 5.0 km single mode fiber spool, our technique reduced SBS threshold by over 48% (measured at 8.5 mW of input signal against 16.5 mW in the conventional technique under same input signal conditions). In addition, the Stokes power was amplified to 9.2 dBm by our method against 4.3 dBm measured in the conventional technique in the 5.0 km single mode fiber spool. Result of different lengths has proved that our technique considerably reduced SBS threshold compared to the conventional method of SBS characterization under same pumping schemes. Wiley-VCH Verlag 2009 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/16465/1/Reduction%20of%20stimulated%20Brillouin%20scattering%20threshold%20through%20pump%20recycling%20technique.pdf Ajiya, Mohammed and Mahdi, Mohd Adzir and Al-Mansoori, Mohammed Hayder and Shee, Yu Gang and Hitam, Salasiah and Mokhtar, Makhfudzah (2009) Reduction of stimulated Brillouin scattering threshold through pump recycling technique. Laser Physics Letter, 6 (7). pp. 535-538. ISSN 1612-2011; ESSN: 1612-202X 10.1002/lapl.200910021
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description We demonstrate a simple method of stimulated Brillouin scattering (SBS) threshold reduction through a procedure of Brillouin pump recycling technique. High reflectivity optical mirror was incorporated onto our experimental structure in order to recycle the forward transmitted Brillouin pump signal back into the Brillouin gain medium thereby increasing its effective gain. In a 5.0 km single mode fiber spool, our technique reduced SBS threshold by over 48% (measured at 8.5 mW of input signal against 16.5 mW in the conventional technique under same input signal conditions). In addition, the Stokes power was amplified to 9.2 dBm by our method against 4.3 dBm measured in the conventional technique in the 5.0 km single mode fiber spool. Result of different lengths has proved that our technique considerably reduced SBS threshold compared to the conventional method of SBS characterization under same pumping schemes.
format Article
author Ajiya, Mohammed
Mahdi, Mohd Adzir
Al-Mansoori, Mohammed Hayder
Shee, Yu Gang
Hitam, Salasiah
Mokhtar, Makhfudzah
spellingShingle Ajiya, Mohammed
Mahdi, Mohd Adzir
Al-Mansoori, Mohammed Hayder
Shee, Yu Gang
Hitam, Salasiah
Mokhtar, Makhfudzah
Reduction of stimulated Brillouin scattering threshold through pump recycling technique.
author_facet Ajiya, Mohammed
Mahdi, Mohd Adzir
Al-Mansoori, Mohammed Hayder
Shee, Yu Gang
Hitam, Salasiah
Mokhtar, Makhfudzah
author_sort Ajiya, Mohammed
title Reduction of stimulated Brillouin scattering threshold through pump recycling technique.
title_short Reduction of stimulated Brillouin scattering threshold through pump recycling technique.
title_full Reduction of stimulated Brillouin scattering threshold through pump recycling technique.
title_fullStr Reduction of stimulated Brillouin scattering threshold through pump recycling technique.
title_full_unstemmed Reduction of stimulated Brillouin scattering threshold through pump recycling technique.
title_sort reduction of stimulated brillouin scattering threshold through pump recycling technique.
publisher Wiley-VCH Verlag
publishDate 2009
url http://psasir.upm.edu.my/id/eprint/16465/1/Reduction%20of%20stimulated%20Brillouin%20scattering%20threshold%20through%20pump%20recycling%20technique.pdf
http://psasir.upm.edu.my/id/eprint/16465/
_version_ 1643826221808615424
score 13.18916