Polymethacrylic Gel (Pmag) as a Point Dosimeter.

Polymethacrylic gel (PMAG) of different concentrations of MAA and BIS were irradiated using γ-rays produced by 60Co radionuclide with the absorbed doses ranging from 0 Gy to 19 Gy. Due to the radiation-induced polymerization processes, the formation of Polymethacrylic gel (PMAG) occurs, which causes...

Full description

Saved in:
Bibliographic Details
Main Authors: Saion, Elias, Iskandar, S.M., Azhar, A.R., Kadni, Taiman, Ab. Rahman, Mohamad Zaki
Format: Article
Language:English
Published: Malaysian Solid State Science and Technology Society (MASS) 2008
Online Access:http://psasir.upm.edu.my/id/eprint/16242/
http://mass-malaysia.net/webjournal/wp-content/uploads/2008/Journal%20MASS%202008%20Jilid%201%20pdf/E.B.%20Saion%20222-231.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.16242
record_format eprints
spelling my.upm.eprints.162422013-06-26T01:15:49Z http://psasir.upm.edu.my/id/eprint/16242/ Polymethacrylic Gel (Pmag) as a Point Dosimeter. Saion, Elias Iskandar, S.M. Azhar, A.R. Kadni, Taiman Ab. Rahman, Mohamad Zaki Polymethacrylic gel (PMAG) of different concentrations of MAA and BIS were irradiated using γ-rays produced by 60Co radionuclide with the absorbed doses ranging from 0 Gy to 19 Gy. Due to the radiation-induced polymerization processes, the formation of Polymethacrylic gel (PMAG) occurs, which causes the dose response mechanism increased in the Nuclear Magnetic Resonance (NMR) relaxation rates of protons. The relaxation rate R2 (1/T2) are fitted to the functional form y as a function of absorbed dose D was found to have a monoexponential expression in the form; y= y + A (1-e -D/D). The relaxation rate (ΔR2) dose sensitivity value (12.5 + 0.1 Gy) of MAA monomer by Lepage, et al 2001 is comparable with PMAAG experimental value gained which are 12.6 + 0.1 Gy. The dose sensitivity, D0 and half dose, D1/2 was found increasing with the concentrations of MAA monomer and BIS crosslinker. The slope parameter kBIS > kMAA indicates that consumption of crosslinker is much faster than monomer. Eventually, UV-Vis spectrophotometer was used to record PMAG degree of absorption. The PMAG has a mean value of absorption of 0.614 at 375 nm. The dose derived from PMAG is comparable to Fricke dosimeter and ionization chamber readings between 4.7 ± 0.1% and 11.6 ± 0.1%. The dose errors of less than 10 ± 0.1% are considered acceptable in radiation processing, an improvement of accuracy less than 5.0 ± 0.1% is acceptable in radiotherapy. This effort is to undertake the study of precision and accuracy associated with the use of Fricke and polymer gel in optimizing the usage of gels for dosimetry. Malaysian Solid State Science and Technology Society (MASS) 2008 Article PeerReviewed Saion, Elias and Iskandar, S.M. and Azhar, A.R. and Kadni, Taiman and Ab. Rahman, Mohamad Zaki (2008) Polymethacrylic Gel (Pmag) as a Point Dosimeter. Solid State Science and Technology, 16 (1). pp. 222-231. ISSN 0128-7389 http://mass-malaysia.net/webjournal/wp-content/uploads/2008/Journal%20MASS%202008%20Jilid%201%20pdf/E.B.%20Saion%20222-231.pdf English
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description Polymethacrylic gel (PMAG) of different concentrations of MAA and BIS were irradiated using γ-rays produced by 60Co radionuclide with the absorbed doses ranging from 0 Gy to 19 Gy. Due to the radiation-induced polymerization processes, the formation of Polymethacrylic gel (PMAG) occurs, which causes the dose response mechanism increased in the Nuclear Magnetic Resonance (NMR) relaxation rates of protons. The relaxation rate R2 (1/T2) are fitted to the functional form y as a function of absorbed dose D was found to have a monoexponential expression in the form; y= y + A (1-e -D/D). The relaxation rate (ΔR2) dose sensitivity value (12.5 + 0.1 Gy) of MAA monomer by Lepage, et al 2001 is comparable with PMAAG experimental value gained which are 12.6 + 0.1 Gy. The dose sensitivity, D0 and half dose, D1/2 was found increasing with the concentrations of MAA monomer and BIS crosslinker. The slope parameter kBIS > kMAA indicates that consumption of crosslinker is much faster than monomer. Eventually, UV-Vis spectrophotometer was used to record PMAG degree of absorption. The PMAG has a mean value of absorption of 0.614 at 375 nm. The dose derived from PMAG is comparable to Fricke dosimeter and ionization chamber readings between 4.7 ± 0.1% and 11.6 ± 0.1%. The dose errors of less than 10 ± 0.1% are considered acceptable in radiation processing, an improvement of accuracy less than 5.0 ± 0.1% is acceptable in radiotherapy. This effort is to undertake the study of precision and accuracy associated with the use of Fricke and polymer gel in optimizing the usage of gels for dosimetry.
format Article
author Saion, Elias
Iskandar, S.M.
Azhar, A.R.
Kadni, Taiman
Ab. Rahman, Mohamad Zaki
spellingShingle Saion, Elias
Iskandar, S.M.
Azhar, A.R.
Kadni, Taiman
Ab. Rahman, Mohamad Zaki
Polymethacrylic Gel (Pmag) as a Point Dosimeter.
author_facet Saion, Elias
Iskandar, S.M.
Azhar, A.R.
Kadni, Taiman
Ab. Rahman, Mohamad Zaki
author_sort Saion, Elias
title Polymethacrylic Gel (Pmag) as a Point Dosimeter.
title_short Polymethacrylic Gel (Pmag) as a Point Dosimeter.
title_full Polymethacrylic Gel (Pmag) as a Point Dosimeter.
title_fullStr Polymethacrylic Gel (Pmag) as a Point Dosimeter.
title_full_unstemmed Polymethacrylic Gel (Pmag) as a Point Dosimeter.
title_sort polymethacrylic gel (pmag) as a point dosimeter.
publisher Malaysian Solid State Science and Technology Society (MASS)
publishDate 2008
url http://psasir.upm.edu.my/id/eprint/16242/
http://mass-malaysia.net/webjournal/wp-content/uploads/2008/Journal%20MASS%202008%20Jilid%201%20pdf/E.B.%20Saion%20222-231.pdf
_version_ 1643826155773493248
score 13.159267