Optimisation of the determination of deoxynivalenol in wheat flour by HPLC and a comparison of four clean-up procedures.
The determination of deoxynivalenol (DON) in wheat flour by liquid chromatography with photodiode array (PDA) detection was optimised. Response surface methodology (RSM) was used to determine the optimum chromatographic conditions for the determination of DON. The influence of three variables, aceto...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English English |
Published: |
Taylor & Francis
2009
|
Online Access: | http://psasir.upm.edu.my/id/eprint/15989/1/Optimisation%20of%20the%20determination%20of%20deoxynivalenol%20in%20wheat%20flour%20by%20HPLC%20and%20a%20comparison%20of%20four%20clean.pdf http://psasir.upm.edu.my/id/eprint/15989/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.upm.eprints.15989 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.159892015-09-14T07:19:24Z http://psasir.upm.edu.my/id/eprint/15989/ Optimisation of the determination of deoxynivalenol in wheat flour by HPLC and a comparison of four clean-up procedures. E. F., Moazami Selamat, Jinap The determination of deoxynivalenol (DON) in wheat flour by liquid chromatography with photodiode array (PDA) detection was optimised. Response surface methodology (RSM) was used to determine the optimum chromatographic conditions for the determination of DON. The influence of three variables, acetonitrile (ACN) volume in mobile phase (9.5-24.5, v/v), flow rate (0.5-1.5 ml min-1) and wavelength (215-221 nm) on DON peak area was evaluated. The best separation was achieved using a symmetry column (150×3.9 mm; particle size 5 µm) by isocratic elution (1.0 ml min-1) and a mobile phase consisting of ACN/water in the ratio 17:83 (v/v). UV detection was performed at 218 nm. Linear calibration curves were constructed in the concentration range 1-1000 ng ml-1. The detection limit measured as the signal-to-noise ratio (3:1) was 0.03 ng ml-1. RSM results showed that the experimental data could be adequately fitted to a second-order polynomial model with multiple regression coefficients (R2) of 0.968. The efficiency of four clean-up procedures for wheat flour extract was compared. Recovery of DON using a Mycosep #225 column was highest with a value of 99%, while that of Mycosep #227 was 65%. In contrast, DON recovery using immunoaffinity columns (IAC) and an Oasis® HLB column was only 53 and 42%, respectively. The trueness of the method using the Mycosep #225 column was established with a certified reference material CRM 379. The result obtained from three replicates was 0.66±0.04 µg g-1 and the certified value was 0.67 µg g-1. Taylor & Francis 2009 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/15989/1/Optimisation%20of%20the%20determination%20of%20deoxynivalenol%20in%20wheat%20flour%20by%20HPLC%20and%20a%20comparison%20of%20four%20clean.pdf E. F., Moazami and Selamat, Jinap (2009) Optimisation of the determination of deoxynivalenol in wheat flour by HPLC and a comparison of four clean-up procedures. Food Additives & Contaminants: Part A, 26 (9). pp. 1290-1297. ISSN 1944-0049 10.1080/02652030903046682 English |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English English |
description |
The determination of deoxynivalenol (DON) in wheat flour by liquid chromatography with photodiode array (PDA) detection was optimised. Response surface methodology (RSM) was used to determine the optimum chromatographic conditions for the determination of DON. The influence of three variables, acetonitrile (ACN) volume in mobile phase (9.5-24.5, v/v), flow rate (0.5-1.5 ml min-1) and wavelength (215-221 nm) on DON peak area was evaluated. The best separation was achieved using a symmetry column (150×3.9 mm; particle size 5 µm) by isocratic elution (1.0 ml min-1) and a mobile phase consisting of ACN/water in the ratio 17:83 (v/v). UV detection was performed at 218 nm. Linear calibration curves were constructed in the concentration range 1-1000 ng ml-1. The detection limit measured as the signal-to-noise ratio (3:1) was 0.03 ng ml-1. RSM results showed that the experimental data could be adequately fitted to a second-order polynomial model with multiple regression coefficients (R2) of 0.968. The efficiency of four clean-up procedures for wheat flour extract was compared. Recovery of DON using a Mycosep #225 column was highest with a value of 99%, while that of Mycosep #227 was 65%. In contrast, DON recovery using immunoaffinity columns (IAC) and an Oasis® HLB column was only 53 and 42%, respectively. The trueness of the method using the Mycosep #225 column was established with a certified reference material CRM 379. The result obtained from three replicates was 0.66±0.04 µg g-1 and the certified value was 0.67 µg g-1. |
format |
Article |
author |
E. F., Moazami Selamat, Jinap |
spellingShingle |
E. F., Moazami Selamat, Jinap Optimisation of the determination of deoxynivalenol in wheat flour by HPLC and a comparison of four clean-up procedures. |
author_facet |
E. F., Moazami Selamat, Jinap |
author_sort |
E. F., Moazami |
title |
Optimisation of the determination of deoxynivalenol in wheat flour by HPLC and a comparison of four clean-up procedures. |
title_short |
Optimisation of the determination of deoxynivalenol in wheat flour by HPLC and a comparison of four clean-up procedures. |
title_full |
Optimisation of the determination of deoxynivalenol in wheat flour by HPLC and a comparison of four clean-up procedures. |
title_fullStr |
Optimisation of the determination of deoxynivalenol in wheat flour by HPLC and a comparison of four clean-up procedures. |
title_full_unstemmed |
Optimisation of the determination of deoxynivalenol in wheat flour by HPLC and a comparison of four clean-up procedures. |
title_sort |
optimisation of the determination of deoxynivalenol in wheat flour by hplc and a comparison of four clean-up procedures. |
publisher |
Taylor & Francis |
publishDate |
2009 |
url |
http://psasir.upm.edu.my/id/eprint/15989/1/Optimisation%20of%20the%20determination%20of%20deoxynivalenol%20in%20wheat%20flour%20by%20HPLC%20and%20a%20comparison%20of%20four%20clean.pdf http://psasir.upm.edu.my/id/eprint/15989/ |
_version_ |
1643826087465058304 |
score |
13.211869 |