Modelling and analysing of a 275 kV HVAC transmission line for power system transient studies
This paper presents the modelling and analyzing of a 275 kV high voltage AC HVAC) transmission line by using PSCAD/EMTDC software. The study is done based on a real 275 kV transmission line which connected from Kampung Awah - Paka, Terengganu. Pi-section model is presented using the parameters obt...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Published: |
EuroJournals Publishing
2008
|
Online Access: | http://psasir.upm.edu.my/id/eprint/15670/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.upm.eprints.15670 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.156702016-01-20T06:51:03Z http://psasir.upm.edu.my/id/eprint/15670/ Modelling and analysing of a 275 kV HVAC transmission line for power system transient studies Ab Kadir, Mohd Zainal Abidin Jay, C. Y. This paper presents the modelling and analyzing of a 275 kV high voltage AC HVAC) transmission line by using PSCAD/EMTDC software. The study is done based on a real 275 kV transmission line which connected from Kampung Awah - Paka, Terengganu. Pi-section model is presented using the parameters obtained from the calculation and is modelled using PSCAD/EMTDC software. The investigation is carried out to determine the efficiency of the transmission line via the concept of travelling wave. The results of performance of the transmission line are then compared and analyzed with the frequency dependent model and these validation results are really useful especially through experimental studies which are based on the Pi-section model. EuroJournals Publishing 2008-12 Article PeerReviewed Ab Kadir, Mohd Zainal Abidin and Jay, C. Y. (2008) Modelling and analysing of a 275 kV HVAC transmission line for power system transient studies. European Journal of Scientific Research, 24 (2). pp. 292-298. ISSN 1450-216X; ESSN: 1450-202X |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
description |
This paper presents the modelling and analyzing of a 275 kV high voltage AC HVAC) transmission line by using PSCAD/EMTDC software. The study is done based on a real 275 kV transmission line which connected from Kampung Awah - Paka, Terengganu. Pi-section model is presented using the parameters obtained from the calculation and is modelled using PSCAD/EMTDC software. The investigation is carried out to determine the efficiency of the transmission line via the concept of travelling wave. The results of performance of the transmission line are then compared and analyzed with the frequency dependent model and these validation results are really useful especially through experimental studies which are based on the Pi-section model. |
format |
Article |
author |
Ab Kadir, Mohd Zainal Abidin Jay, C. Y. |
spellingShingle |
Ab Kadir, Mohd Zainal Abidin Jay, C. Y. Modelling and analysing of a 275 kV HVAC transmission line for power system transient studies |
author_facet |
Ab Kadir, Mohd Zainal Abidin Jay, C. Y. |
author_sort |
Ab Kadir, Mohd Zainal Abidin |
title |
Modelling and analysing of a 275 kV HVAC transmission line for power system transient studies |
title_short |
Modelling and analysing of a 275 kV HVAC transmission line for power system transient studies |
title_full |
Modelling and analysing of a 275 kV HVAC transmission line for power system transient studies |
title_fullStr |
Modelling and analysing of a 275 kV HVAC transmission line for power system transient studies |
title_full_unstemmed |
Modelling and analysing of a 275 kV HVAC transmission line for power system transient studies |
title_sort |
modelling and analysing of a 275 kv hvac transmission line for power system transient studies |
publisher |
EuroJournals Publishing |
publishDate |
2008 |
url |
http://psasir.upm.edu.my/id/eprint/15670/ |
_version_ |
1643825995561566208 |
score |
13.211869 |