Histomorphometric profile of the corneal response to short-term reverse-geometry orthokeratology lens wear in primate corneas: a pilot study

Purpose: To investigate the histological changes in primate cornea induced by short-term overnight orthokeratology (OK). Methods: Nine young adult primates were used. One animal served as negative control. The remaining 8 animals wore reverse-geometry OK lenses for periods of 4, 8, 16, and 24 hours...

Full description

Saved in:
Bibliographic Details
Main Authors: Cheah, Pike See, Mohidin, Norhani, Mohd Ali, Bariah, Myint, Maung, Lye, Munn Sann, Abdul Latiff, Azian
Format: Article
Language:English
Published: Lippincott Williams & Wilkins 2008
Online Access:http://psasir.upm.edu.my/id/eprint/15018/1/Histomorphometric%20profile%20of%20the%20corneal%20response%20to%20short-term%20reverse-geometry%20orthokeratology%20lens%20wear%20in%20primate%20corneas%20a%20pilot%20study.pdf
http://psasir.upm.edu.my/id/eprint/15018/
https://journals.lww.com/corneajrnl/fulltext/2008/05000/Histomorphometric_Profile_of_the_Corneal_Response.13.aspx
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.15018
record_format eprints
spelling my.upm.eprints.150182019-10-31T01:13:39Z http://psasir.upm.edu.my/id/eprint/15018/ Histomorphometric profile of the corneal response to short-term reverse-geometry orthokeratology lens wear in primate corneas: a pilot study Cheah, Pike See Mohidin, Norhani Mohd Ali, Bariah Myint, Maung Lye, Munn Sann Abdul Latiff, Azian Purpose: To investigate the histological changes in primate cornea induced by short-term overnight orthokeratology (OK). Methods: Nine young adult primates were used. One animal served as negative control. The remaining 8 animals wore reverse-geometry OK lenses for periods of 4, 8, 16, and 24 hours on 1 eye with the other eye as control. Central and midperipheral corneal thickness, as well as ultrastructural changes in corneal epithelium, stroma and endothelium in response to OK lenses, were evaluated. Results: OK significantly reduced the thickness of the central cornea in all treatment groups. The central corneal thinning was both stromal and epithelial in origin. Substantial midperipheral corneal thickening was seen in 16-hour and 24-hour lens-wear groups and this effect was both stromal and epithelial in origin as well. Histology evidence indicated the primary epithelial response in the central cornea was compression of cells that resulted in wing cells becoming shorter and basal cells being squatted rather than lost or migration of cell layers. These pronounced cell shape changes occurred without compromising the structural integrity of the desmosomes. The thickened corneal epithelium has normal cell layers. The squamous cells have larger surface sizes and are composed of oval instead of flattened nuclei. This implied delayed surface cell exfoliation at the thickened midperipheral epithelium. Physical presence of OK lens over the cornea did not influence the microstructures of microvilli and microplicae, endothelium, and collagen distribution. Conclusions: The primate cornea, particularly the corneal epithelium, responds rapidly to the application of reverse-geometry OK lenses with significant epithelial cell shape alterations with short-term OK lens wear. This finding suggests that the corneal epithelium is moldable in response to the physical forces generated by the OK lenses. Lippincott Williams & Wilkins 2008-05 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/15018/1/Histomorphometric%20profile%20of%20the%20corneal%20response%20to%20short-term%20reverse-geometry%20orthokeratology%20lens%20wear%20in%20primate%20corneas%20a%20pilot%20study.pdf Cheah, Pike See and Mohidin, Norhani and Mohd Ali, Bariah and Myint, Maung and Lye, Munn Sann and Abdul Latiff, Azian (2008) Histomorphometric profile of the corneal response to short-term reverse-geometry orthokeratology lens wear in primate corneas: a pilot study. Cornea, 27 (4). pp. 461-470. ISSN 0277-3740; ESSN: 1536-4798 https://journals.lww.com/corneajrnl/fulltext/2008/05000/Histomorphometric_Profile_of_the_Corneal_Response.13.aspx 10.1097/ICO.0b013e318165642c
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description Purpose: To investigate the histological changes in primate cornea induced by short-term overnight orthokeratology (OK). Methods: Nine young adult primates were used. One animal served as negative control. The remaining 8 animals wore reverse-geometry OK lenses for periods of 4, 8, 16, and 24 hours on 1 eye with the other eye as control. Central and midperipheral corneal thickness, as well as ultrastructural changes in corneal epithelium, stroma and endothelium in response to OK lenses, were evaluated. Results: OK significantly reduced the thickness of the central cornea in all treatment groups. The central corneal thinning was both stromal and epithelial in origin. Substantial midperipheral corneal thickening was seen in 16-hour and 24-hour lens-wear groups and this effect was both stromal and epithelial in origin as well. Histology evidence indicated the primary epithelial response in the central cornea was compression of cells that resulted in wing cells becoming shorter and basal cells being squatted rather than lost or migration of cell layers. These pronounced cell shape changes occurred without compromising the structural integrity of the desmosomes. The thickened corneal epithelium has normal cell layers. The squamous cells have larger surface sizes and are composed of oval instead of flattened nuclei. This implied delayed surface cell exfoliation at the thickened midperipheral epithelium. Physical presence of OK lens over the cornea did not influence the microstructures of microvilli and microplicae, endothelium, and collagen distribution. Conclusions: The primate cornea, particularly the corneal epithelium, responds rapidly to the application of reverse-geometry OK lenses with significant epithelial cell shape alterations with short-term OK lens wear. This finding suggests that the corneal epithelium is moldable in response to the physical forces generated by the OK lenses.
format Article
author Cheah, Pike See
Mohidin, Norhani
Mohd Ali, Bariah
Myint, Maung
Lye, Munn Sann
Abdul Latiff, Azian
spellingShingle Cheah, Pike See
Mohidin, Norhani
Mohd Ali, Bariah
Myint, Maung
Lye, Munn Sann
Abdul Latiff, Azian
Histomorphometric profile of the corneal response to short-term reverse-geometry orthokeratology lens wear in primate corneas: a pilot study
author_facet Cheah, Pike See
Mohidin, Norhani
Mohd Ali, Bariah
Myint, Maung
Lye, Munn Sann
Abdul Latiff, Azian
author_sort Cheah, Pike See
title Histomorphometric profile of the corneal response to short-term reverse-geometry orthokeratology lens wear in primate corneas: a pilot study
title_short Histomorphometric profile of the corneal response to short-term reverse-geometry orthokeratology lens wear in primate corneas: a pilot study
title_full Histomorphometric profile of the corneal response to short-term reverse-geometry orthokeratology lens wear in primate corneas: a pilot study
title_fullStr Histomorphometric profile of the corneal response to short-term reverse-geometry orthokeratology lens wear in primate corneas: a pilot study
title_full_unstemmed Histomorphometric profile of the corneal response to short-term reverse-geometry orthokeratology lens wear in primate corneas: a pilot study
title_sort histomorphometric profile of the corneal response to short-term reverse-geometry orthokeratology lens wear in primate corneas: a pilot study
publisher Lippincott Williams & Wilkins
publishDate 2008
url http://psasir.upm.edu.my/id/eprint/15018/1/Histomorphometric%20profile%20of%20the%20corneal%20response%20to%20short-term%20reverse-geometry%20orthokeratology%20lens%20wear%20in%20primate%20corneas%20a%20pilot%20study.pdf
http://psasir.upm.edu.my/id/eprint/15018/
https://journals.lww.com/corneajrnl/fulltext/2008/05000/Histomorphometric_Profile_of_the_Corneal_Response.13.aspx
_version_ 1651869000477442048
score 13.214268