A Critical Review on the Contamination Effect on Distribution Overhead Lines

Year by year, performance of the power system distribution lines is one of the important subject that need to be considered. This paper presents a review on the effects of contamination on distribution overhead lines. Apart from the physical configuration of the lines such as lower in height and...

Full description

Saved in:
Bibliographic Details
Main Authors: Ab Kadir, Mohd Zainal Abidin, Mohd Nowi, Zawati, Misbah, Nor Ratna
Format: Article
Language:English
English
Published: Praise Worthy Prize 2010
Online Access:http://psasir.upm.edu.my/id/eprint/12116/1/A%20Critical%20Review%20on%20the%20Contamination%20Effect%20on%20Distribution%20Overhead%20Lines.pdf
http://psasir.upm.edu.my/id/eprint/12116/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.12116
record_format eprints
spelling my.upm.eprints.121162015-10-28T04:43:38Z http://psasir.upm.edu.my/id/eprint/12116/ A Critical Review on the Contamination Effect on Distribution Overhead Lines Ab Kadir, Mohd Zainal Abidin Mohd Nowi, Zawati Misbah, Nor Ratna Year by year, performance of the power system distribution lines is one of the important subject that need to be considered. This paper presents a review on the effects of contamination on distribution overhead lines. Apart from the physical configuration of the lines such as lower in height and simple build-up structure, the location of the lines and the withstand capability of the systems are among another factors that determine the performance of the line. Insulator, which is used in between the cross-arm and phase conductor for instance, is very much sensitive to the surrounding environment such as humidity (wet and dry) and contamination such as salt, cement, dust, smog and etc. In the event of the direct or indirect effects of the lightning for instance, this contamination will affect the breakdown strength of the insulator which will result in the flashover across the insulator or coordination gap. This paper will consider in details the effect from different contaminants and different types of testing in evaluating the performance of the insulator. At the end of the paper, some mitigations approaches will be suggested with respect to the issue being discussed. Praise Worthy Prize 2010 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/12116/1/A%20Critical%20Review%20on%20the%20Contamination%20Effect%20on%20Distribution%20Overhead%20Lines.pdf Ab Kadir, Mohd Zainal Abidin and Mohd Nowi, Zawati and Misbah, Nor Ratna (2010) A Critical Review on the Contamination Effect on Distribution Overhead Lines. International Review of Electrical Engineering, 5 (5). pp. 2461-2470. ISSN 1827-6660 English
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
English
description Year by year, performance of the power system distribution lines is one of the important subject that need to be considered. This paper presents a review on the effects of contamination on distribution overhead lines. Apart from the physical configuration of the lines such as lower in height and simple build-up structure, the location of the lines and the withstand capability of the systems are among another factors that determine the performance of the line. Insulator, which is used in between the cross-arm and phase conductor for instance, is very much sensitive to the surrounding environment such as humidity (wet and dry) and contamination such as salt, cement, dust, smog and etc. In the event of the direct or indirect effects of the lightning for instance, this contamination will affect the breakdown strength of the insulator which will result in the flashover across the insulator or coordination gap. This paper will consider in details the effect from different contaminants and different types of testing in evaluating the performance of the insulator. At the end of the paper, some mitigations approaches will be suggested with respect to the issue being discussed.
format Article
author Ab Kadir, Mohd Zainal Abidin
Mohd Nowi, Zawati
Misbah, Nor Ratna
spellingShingle Ab Kadir, Mohd Zainal Abidin
Mohd Nowi, Zawati
Misbah, Nor Ratna
A Critical Review on the Contamination Effect on Distribution Overhead Lines
author_facet Ab Kadir, Mohd Zainal Abidin
Mohd Nowi, Zawati
Misbah, Nor Ratna
author_sort Ab Kadir, Mohd Zainal Abidin
title A Critical Review on the Contamination Effect on Distribution Overhead Lines
title_short A Critical Review on the Contamination Effect on Distribution Overhead Lines
title_full A Critical Review on the Contamination Effect on Distribution Overhead Lines
title_fullStr A Critical Review on the Contamination Effect on Distribution Overhead Lines
title_full_unstemmed A Critical Review on the Contamination Effect on Distribution Overhead Lines
title_sort critical review on the contamination effect on distribution overhead lines
publisher Praise Worthy Prize
publishDate 2010
url http://psasir.upm.edu.my/id/eprint/12116/1/A%20Critical%20Review%20on%20the%20Contamination%20Effect%20on%20Distribution%20Overhead%20Lines.pdf
http://psasir.upm.edu.my/id/eprint/12116/
_version_ 1643824947957596160
score 13.211869